background image

7

Selection PRO

C

UTILIZAREA

OPERATION

Set up laser
1.  On a tripod: Connect laser to 5/8“ 

retaining bolt of builder‘s tripod.

2.  On the floor: Set up on floor 

tripod. Fine adjustment with 
adjustable tripod legs.

Set up instrument as upright as 
possible by means of vial to allow the 
self-levelling system to function within 
the range.

Fiola circulara cu bula

5/8“-Adapter

COMUTATOR PORNIRE

SWITCH ON

Switch instrument on by pressing 
button (7). Instrument is now ready for 
use (keypad is illuminated). An audible 
and optical (blinking lines) alarm 
indicates if the instrument was set up 
outside of compensator range. Set up 
instrument on a more even surface.

To switch off press button (7) again. 
Instrument is now switched off.

Configurați laserul
1. Pe un trepied: conectați laser la șurubul 
de  fixare  de  5/8  "al  trepiedului  de 
constructii
2.  Pe  podea:  Amplasati  pe  trepiedul  de 
podea  a  instrumentului.  Reglare  fină  cu 
picioare reglabile pentru trepied.

Configurați  instrumentul  cât  mai  drept 
posibil  cu  ajutorul  unui  flacon  pentru  a 
permite  sistemului  de  auto-nivelare  să 
funcționeze în interiorul gamei.

Porniți  instrumentul  apăsând  butonul 
(7).  Instrumentul  este  acum  gata  de 
utilizare  (tastatura  este  aprinsă).  O 
a l a r m ă   s o n o r ă   ș i   o p t i c ă   ( l i n i i 
intermitente) indică dacă instrumentul a 
fost  configurat  în  afara  domeniului  de 
compensare.  Configurați  instrumentul 
pe o suprafață mai dreapta.

Pentru a opri din nou butonul (7) din nou.
Instrumentul este acum oprit.

Содержание FL 70 Premium-Liner SP

Страница 1: ...MANUAL INSTRUCTIUNI SelectionPRO www geo fennel echipamente ro FL 70 Premium Liner SP...

Страница 2: ...rudence Among others Selection PRO is de ned by even clearer visible lines which you are originally used to from our standard range of instruments This manual will help you to operate the instrument a...

Страница 3: ...h IP 54 635 nm 2 10 C 45 C SPECIFICATII TEHNICE Domeniu autonivelare Precizie Domeniu lucru fara receptor cu receptor Sursa alimentare Timp operare Protectie praf apa Laser dioda Laser clasa Domeniu...

Страница 4: ...lara cu bula 3 3 x ferestre emisie laser 4 Rotita ajustare na 5 Compartiment baterii 6 Picioare ajustabile OPERATIONAL ELEMENTS 1 Keypad 2 Circular bubble 3 3 x laser output window 4 Fine adjusting ha...

Страница 5: ...nction for receiver operation 4 LED pulse function 5 Selection of horizontal laser lines 6 LED ON OFF 7 ON OFF button 8 LED SLOPE direction indicator X Y Cerc cu miscare tangentiala cu surub ROTATABLE...

Страница 6: ...n battery pack can be charged outside of the instrument Ladebuchse Charging socket Incarcator Cutie baterii alcaline Compartiment baterii reincarcabile Incarcarea se poate face si in afara instrumentu...

Страница 7: ...strument on a more even surface To switch o press button 7 again Instrument is now switched o Con gura i laserul 1 Pe un trepied conecta i laser la urubul de xare de 5 8 al trepiedului de constructii...

Страница 8: ...lines will be a little bit weaker than usual Dup comutarea instrumentului pe liniile laser pot selectate dup cum urmeaz butonul nr 1 imagini 1 2 butonul nr 5 imaginile 5 8 Linii laser orizontale Ap sa...

Страница 9: ...er line Press MAN button again to quit MANUAL function DEMONSTRATIE APLICATII Tastatura telecomanda TastaMAN selectati axa de inclinare sageti pentru modul INCLINARE Func ia MANUAL poate executat numa...

Страница 10: ...ound on o 5 Detected position indicator DATE TEHNICE Indicatie LED uri Precizie Tonuri Sursa alimentare Display fata ambele p r i 1 mm 3 1 x 9V TECHNICAL DATA Indication LEDs Accuracy Tones Power Supp...

Страница 11: ...indication line 13 1 4 mounting hole for clamp 14 Battery compartment INSTALAREA BATERIILOR INSTALLATION OF BATTERIES Open battery compartment cover 14 Put in 1 x 9 V AA battery according to installat...

Страница 12: ...the same technology as rotating laser levels Because of this the receiver FR 55 must be moved much more sensitively IMPORTANT pentru a detecta fasciculul laser muta i receptorul FR 55 n sus i n jos n...

Страница 13: ...IGLA DE NIVELARE CLAMP FOR LEVELLING STAFF If required mount FR 55 to clamp It then can be attached to laser poles or any other equipment Dac este necesar monta i FR 55 la clem Acesta poate apoi ata a...

Страница 14: ...losive environment The user manual must always be kept with the instrument Urma i instruc iunile din manualul de utilizare Nu privi i n raz Fasciculul laser poate duce la v t marea ochilor O privire d...

Страница 15: ...rmally secured by aversion responses and the blink re ex The laser instrument is marked with class 2 warning labels Instrumentul este un laser laser de clasa 2 conform DIN IEC 60825 1 2008 5 Este perm...

Страница 16: ...inal container case only NOTE During transport the base must be set to position OFF Disregard may lead to damage of compensator Instrumentul emite un fascicul laser vizibil pentru a efectua urm toarel...

Страница 17: ...r way around please wait some minutes before carrying out mea surements CE CONFORMITATE CE CONFORMITY Instrument has CE mark according to EN 61010 1 2001 corr 1 2 IEC 60825 1 2008 5 M sur tori prin fe...

Страница 18: ...ttery bending or dropping the unit are presumed to be defects resulting from misuse or abuse Acest produs este garantat de c tre produc tor pentru cump r torul ini ial pentru a lipsit de defecte de ma...

Страница 19: ...ge caused by wrong movement or action due to connecting with other products Se a teapt ca utilizatorul acestui produs s urmeze instruc iunile din manualul operatorului De i toate instrumentele au ie i...

Отзывы: