13
EN
Center the vial
1
VERTICAL USE
For vertical use it is absolutely required to set
the compensator clamp (1) to OFF.
Set up the instrument with its wallmount on a
flat smooth surface or mount it onto a tripod
with its 5/8“ thread.
Center the vial for vertical application by
means of the foot screw (8). Take care to set
the vial very precisely as the compensator will
not work in vertical mode.
For the functions please see „horizontal use“.
NOTE
During transport and in vertical use the com-
pensator clamp must be set to OFF. Disregard
may lead to damage of the unit!
HORIZONTAL USE
Set up the instrument on a flat smooth surface or
mount it onto a tripod.
Release the compensator clamp, which protects
the instrument from damages during transport, by
turning wheel (1) to ON until stop.
Press the ON/OFF button of the keypad. The instru-
ment will level automatically within the self-levelling
range of ± 3°. The laser head starts rotating. Select
the rotating speed with button (6) of the keypad. The
LEDs will show the rotating speed selected: LED
H = (600 rpm), LED M (= 400 rpm), LED
L (= 200 rpm).
An audible signal indicates if the instrument was set
up outside of the compensator range of ± 3°. The
laser head stops rotating. Set up the laser on a more
even surface.