- Technishce Änderungen vorbehalten -
2. Before Installation /
Placement into service
Deliverance
Heat pump including controller
Installation manual with technical data
User manual for controller
2.1 Important safety instructions
In the design and implementation of the Vanvex R, all
relevant EU guidelines have been adhered to.
Work on the Vanvex R may only be performed
by trained personnel! Take all necessary
precautions in order to avoid accidents while
working!
2.1.1 Cooling system – safety instructions
The trained repairman must see to it that parts containing
the refrigerant are emptied to a level at which the execution
of the work can occur in a responsible manner without any
dangers, before the commencement of repairs and service
work.
When repairing and servicing the Vanvex R with the
refrigerant system opened, and particularly for work with an
open flame (soldering, welding, etc.), precautions must be
taken to prevent fires from starting.
2.1.2 Electrical circuit – safety instructions
When working on the Vanvex R, the main
supply must always be disconnected – pull the
plug out!
When connecting the Vanvex R to the power supply, the
local and national rules and norms must be adhered to.
In addition, regard must be paid to possible requirements
posed by the energy supplier.
2.1.3 Water circuit – safety instructions
Only drinking water quality water may be used. During
installation, regard must be paid to the choice of materials
and it must be ensured that they can work together without
problems in the entire circuit.
Special attention must be paid when using
galvanised components and components
containing aluminium!
Safety equipment must be installed to prevent over pressure
in the system.
All pipe work must comply with water safety regulations.
2.2 Delivery
The Vanvex R is delivered without water, condense water
tube and the safety equipment for the water circuit.
2.3 Storage
The Vanvex R must be stored upright without water and in
its packaging.
2.4 Transport
When carefully transporting the Vanvex R over short
distances, it can be tilted up to 45°C. If this limit is
exceeded, the Vanvex R must stand in its normal upright
position for at least 1 hour before it may be started.
Transport and storage may take place at temperatures
between -10 and +50 °C.
The Vanvex R’s top / casing is not suitable for lifting with
and must be carefully avoided during transport.
2.4.1 Transport with forklift
For transport with a forklift, the Vanvex R must stand on the
associated transport frame. Always lift it slowly. Due to the
high position of the centre of gravity, the Vanvex R must be
secured against tipping during transportation.
2.4.2 Unloading the heat pump
In order to avoid damages, the Vanvex R must be
unloaded on a flat surface.
2.4.3 Transport with trolley
The Vanvex R may only be transported on an associated
transport frame.
The Vanvex R must be secured against sliding on the
trolley.
Water connections, etc., may not be used for transportation
purposes.
Make sure that the trolley does not damage the cabinet
and the connections.
2.5 Placement /set-up
The Vanvex R may only be installed in a frost-free room.
The installation location should comply with the following
criteria:
• Room temperature between 0 and +35°C.
• Drain possibility for condensate water.
• No abnormal dust concentration in the air.
• Solid base (approx. 500 kg / m²)
• To achieve problem-free functioning and to allow
access for service, it is recommended that 0.5 m
free space be maintained around the unit.
Set-up sequence:
1. Remove the packaging from the pallet.
2. Remove the transport fittings from the pallet.
3. Take the Vanvex R off the pallet and place it at the
desired location.
Adjust the Vanvex R vertically by adjusting the feet.
Installation Manual