6. FAQ

Error item

Check list

When power is 

not 

turned on

Press and hold the power button for more than 3 seconds. A short 
push will not power up.

Please make sure that 9V battery is installed.

Make sure that the battery power is at least 7 V. 
If it is below 7 V, the power is not turned on or low battery picture is 
output.

When the 

screen is 

dimmed

Please replace the battery. Depending on the voltage consumption of 
the battery, the screen may become blurred.

the battery

change 

picture is 

displayed

This indicates when the battery should be replaced. Please replace 
the battery. 

When the 

measured 

value is [0.0]

Check that the light source is on.
For UV index meters, measurements may be impossible on cloudy 
days.

Make sure that the incident surface of the sensor probe is 
perpendicular to the light source.

Check the detection wavelength range of the measuring instrument 
and the wavelength of the light source. 
The detection wavelength range can be found on page 4 of the 
manual and on the back of the measuring instrument.

When the 

measured 

value differs 

depending on 

the 

light source

Please check page 15 relative response curve.
Even if included in the measurement range, the output value may vary 
depending on the wavelength of the light source.
The calibration light source information for the measuring instrument 
can be found on page 14.

When the 

measured 

value is 

measured 

low

In the case of a UV index meter, the measured value may be low or 
not measured on cloudy days. 

Make sure that the sensor measuring surface is positioned 
perpendicular to the light source. 
If the angle is tilted, accurate measurements will not be made.

Check if there is foreign substance on the sensor measurement 
surface.
Foreign matter such as oil or dust can cause a decrease in light 
quantity.

When power is 

off 

during use

If sleep time is not “Infinite”, the power is automatically turned off. 
In this case, it is in normal operation.

Содержание GFUVT10GS8

Страница 1: ...Genicom Co Ltd Page 1 Manual GUVX T1XGS8 Radiometer 8 20210310 V0 1 CH LEE...

Страница 2: ...Genicom Co Ltd Page 2 MG 08 GUVX T1XGS8 L LA9 2 User Manual...

Страница 3: ...8 Detection 0 00 99 99 0 50 0 UVI Spectral Detection Range 230 395 n 220 320 n 220 280 n 220 320 n 250nm 330 445 220 320nm Calibration Peak Point 365 nm LED 306 nm Lamp 254 nm Lamp 285 nm LED 222nm r...

Страница 4: ...eter to extremes in temperature humidity When the surface contamination of the product wipe with a Keep sensor free of oil dirt etc Do not disassemble if modification 1 GUVV T10GS8 L LA9 2 2 GUVB T11G...

Страница 5: ...E Function Button OK Button Press 1 second to perform logging more 3 second to enter menu ESC Button Press 1 second to reset DOSE value and Max Power Press short to measure pause start UP Button Press...

Страница 6: ...asurement wavelength range Products Information Sticker Battery Cover Model No GUVX T1XS L Type UV Index Meter Detection Range XXX XXX nm Power Range 0 100 0 NIST Traceable Made in KOREA by Genicom Co...

Страница 7: ...he back of main unit and check for a 9V battery is or isn t Pulling the connector forcibly can cause it to break Please hold the battery connector and detach the battery 5 Product Operation Guide 5 1...

Страница 8: ...on for 1 second to start DOSE Press again for 1 second to exit at DOSE Press 1 second logging Measurement Mode Logging Mode 1Press 1 second DOSE Measurement Mode DOSE Mode SN MG08201217001 uW Cm2 323...

Страница 9: ...n for 1 second to cycle into measurement mode information mode DOSE Graph mode UVC Safer mode and measurement mode Press 1 second UVC SAFE DOSE GRAPH Mode UVC SAFE Mode 00 00 00 323 uW Cm2 323 0 UVC S...

Страница 10: ...1 second zero Set Measurement Mode Zero set uW Cm2 323 0 20 12 17 11 52 32 uW Cm2 0 000 20 12 17 11 52 32 Press the ESC button shortly to pause the measured value Press again shortly to displays the m...

Страница 11: ...ton for 3 seconds to display the setting menu In the setting menu you can set the date time set the network mode adjust the backlight brightness export the saved log set the relay set the sleep time a...

Страница 12: ...5 Relay Control 6 Sleep Time Current network Mode None Update Network Mode None AP BT Export Log In the menu mode select 3 Export Log by using the UP and DOWN buttons d means a directory and f means...

Страница 13: ...Mode 1 Setup Date Time 2 Network Mode 3 Export Log 4 LCD Backlight 5 Relay Control 6 Sleep Time now brightness 2 Update brightness 0 Changing a relay operation condition In the menu mode select 5 Rel...

Страница 14: ...tery consumption is high so setting the minimum value of 1m can reduce battery consumption Press OK Button Changing a Sleep Time Menu Mode 1 Setup Date Time 2 Network Mode 3 Export Log 4 LCD Backlight...

Страница 15: ...lay Control 6 Sleep Time Current network Mode None Update Network Mode None AP BT Select AP in network setting mode and press OK button for 1 second to return to menu mode In the menu mode Select 8 ex...

Страница 16: ...rface of the sensor is positioned perpendicular to the UV light source or solar light that you want to measure If the LCD does not have any remaining battery meter please replace the battery uW Cm2 32...

Страница 17: ...he measuring instrument and the wavelength of the light source The detection wavelength range can be found on page 4 of the manual and on the back of the measuring instrument When the measured value d...

Страница 18: ...f procurement with no charge However failure which is caused by user s misuse or carelessness within warrant period or any failure after the warrant period shall be chargeable for it s A S Product inq...

Страница 19: ...Genicom Co Ltd Page 19 MEMO...

Страница 20: ...Genicom Co Ltd Page 20...

Отзывы: