 CONTROL FUNCTION                                           

ENGINE SWITCH 

The engine switch controls the ignition system. 

 

   

“ON” 

Ignition circuit is switched on. 

The engine can be started. 

 

 

OFF”

 

Ignition circuit is switched off. 

The engine will not run. 

AC BREAKER (N.F.B) 

The AC breaker turns off automatically when the load exceeds the generator rated output.Press the reset button to 

reset the protector. 

CAUTION: 

Reduce the load to within specified generator rated output if the AC breaker (N.F.B) turns off. 

DC BREAKER (N.F.B) 

The DC breaker turns off automatically when the load exceeds the generator rated output. 

  PRE-OPERATION CHECK 

NOTE:  

Pre-operation checks should be made each time when the generator is used. 

! WARNING

 

The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler 

while they are still hot with any part of your body or clothing during inspection or repair. 

FUEL

   

Make sure there is sufficient fuel in the tank. 

 

 

 

 

 

 

z

 

Use oil-mixed gasoline ,or engine will be overheated.Gasoline and oil mixing ration is 50:1 or 40:1(in the 

summer). 

z

 

Use clean,fresh,regular unleaded gasoline with a minimum of 77 octane. 

z

 

Use special purpose oil for 2-stroke. 

Recommended fuel: Oil-mixed gasoline 

Fuel tank capacity: 4.2L                               

Содержание 950W Series

Страница 1: ...fore attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with the user manual could result in per...

Страница 2: ...1 CONTENTS 1 SAFETY INFORMATION 2 2 CONTROL FUNCTION 2 3 PRE OPERATION CHECK 3 4 OPERATION 4 5 PERIODIC MAINTENANCE 5 6 STORAGE 6 7 SPECIFICATIONS 7 8 GENERATOR SCHEME DIAGRAM 8...

Страница 3: ...he machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fuel tank ENGINE AND MUFFLER MAY BE HOT z Place the machine in a place where pedestrians or children are not like...

Страница 4: ...atically when the load exceeds the generator rated output PRE OPERATION CHECK NOTE Pre operation checks should be made each time when the generator is used WARNING The engine and muffler will be very...

Страница 5: ...flame cigarettes etc away Ventilate when charging or using in closed space Always cover eyes when working near batteries Keep out of reach of children OPERATION STARTING THE ENGINE NOTE z Before star...

Страница 6: ...tus z Reduce the load to within specified generator rated output if the AC breaker N F B turns off DC OUTPUT NOTE Battery charging if equipped Red lead to positive black to negative CAUTION This batte...

Страница 7: ...ilter Clean Replace if necessary z Fuel Filter Clean fuel filter Re Place if necessary z Fuel Line Check fuel hose for crack or damage Re place if necessary z Check for leakage Retighten or replace ga...

Страница 8: ...031in FUEL TANK FILTER Clean with solvent Wipe off WARNING Be sure the tank cap is tightened securely TROUBLESHOOTING ENGINE WON T START 1 Fuel systems No fuel supplied to combustion chamber z No fue...

Страница 9: ...l starter until you feel compression Stop pulling Clean exterior of the generator and apply a rust inhibitor Store the generator in a dry well ventilated place with the cover place over it The generat...

Страница 10: ...e Mixed oil brume lubrication Fuel No 90 gasoline Oil No Purpose oil for 2 stroke Starting Manual starting Output Mode Horizontal cone shaped shaft output Ignition C D I z Specifications subject to ch...

Страница 11: ...10 SC Stator Auxiliary Winding...

Отзывы: