This alarm monitors the air at the device and is designed to

alarm before CO levels become life threatening. This allows

precious time to leave the house and correct the problem. This is

only possible if the devices are properly located, installed and

maintained as described in this manual.

Gas Detection at Typical Temperature and Humidity Ranges:

This device is not formulated to detect CO levels below 30 ppm

typically. UL tested for false alarm resistance to Methane (500 ppm),

Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm),

Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm).

Values measure gas and vapor concentrations in parts per million.

Audible Alarm:

85dBA minimum at 10 feet (3 meters).

TO RETURN A CO ALARM

Should you experience problems with your CO alarm,

proceed as follows:

1. Turn off electrical power to the CO alarm.

2. Twist the CO alarm counter-clockwise to remove it from its

mounting plate.

3. Unplug the connector from the back of the CO alarm. Do not

remove the wire connection; leave the connector for your

replacement CO alarm.

4. Remove battery from CO alarm. Do not ship CO alarm

with battery still in battery drawer.

5. Carefully pack (the manufacturer cannot be responsible for

consequential damage) and return to the manufacturer. Include

complete details as to exact nature of difficulties being

experienced and date of installation.

6. Return to: Gentex Corporation, 10985 Chicago Drive, Zeeland,

Michigan 49464. Prior to returning, call Gentex at 800-436-8391

or e-mail [email protected] to obtain a RMA Number from

our return department.

Pg. C-8

LIMITED WARRANTY

For a period of 12 months from the date of purchase, or a maximum of 18 months from the date of manufacture,

Gentex warrants to you, the original consumer purchaser, that your CO Alarm will be free from defects in

workmanship, materials, and construction under normal use and service. The CO sensor has a limited warranty

period of 5 years from date of installation. If a defect in workmanship, materials, or construction should cause

your CO Alarm to become inoperable within the warranty period, Gentex will repair your CO Alarm or furnish you

with a new or rebuilt replacement CO Alarm without charge to you except for postage required to return the CO

Alarm to us. Your repaired or replacement CO Alarm will be returned to you free of charge and it will be covered

under this warranty for the balance of the warranty period.

This warranty is void if our inspection of your CO Alarm shows that the damage or failure was caused by

abuse, misuse, abnormal usage, faulty installation, improper maintenance, or repairs other than those performed

by us.

ANY WARRANTIES IMPLIED UNDER ANY STATE LAW, INCLUDING IMPLIED WARRANTIES OF

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLY ONLY FOR THE

WARRANTY PERIOD SPECIFIED ABOVE. PLEASE NOTE THAT SOME STATES DO NOT ALLOW

LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSION MAY NOT

APPLY TO YOU.

GENTEX WILL NOT BE LIABLE FOR ANY LOSS, DAMAGE, INCIDENTAL OR CONSEQUENTIAL

DAMAGES OF ANY KIND ARISING IN CONNECTION WITH THE SALE, USE, OR REPAIR OF THIS CO

ALARM. PLEASE NOTE THAT SOME STATES DO NOT ALLOW THE EXCLUSION OR

LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. SO THE ABOVE EXCLUSION MAY NOT

APPLY TO YOU.

If a defect in workmanship, materials, or construction should cause your CO Alarm to become

inoperable within the warranty period, you must return the CO Alarm to Gentex postage prepaid. You must also

pack the CO Alarm to minimize the risk of it being damaged in transit. You must also enclose a return address.

CO Alarms returned for warranty service should be sent to: Gentex Corporation, 10985 Chicago Drive, Zeeland,

MI 49464.

If we receive a CO Alarm in a damaged condition as the result of shipping, we will notify you and you must

file a claim with the Shipper.

THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER

RIGHTS WHICH VARY FROM STATE TO STATE.

GENTEX CORPORATION

10985 CHICAGO DRIVE, ZEELAND, MI 49464

PHONE: 1-800-436-8391

www.gentex.com

550-0498-A

08-01-08

Important Notice:
These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no rep-

resentations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal

considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the

obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not

be responsible for any action or failure to act in reliance upon the information contained in this material.

WARNING!

CO alarms are designed to alarm before there is an

immediate life threat. Since CO gas can not be seen or smelled,

never assume it is not present.

An exposure to 100 ppm of CO for 20 minutes may not affect a

healthy adult, after 4 hours of exposure at the same level may

cause headache.

An exposure to 400 ppm of CO may cause headaches in a healthy

adult after 35 minutes and could cause death after 2 hours.

NOTICE:

This device measures exposure to CO over time. This

device alarms if CO levels reach a certain minimum over an extend-

ed amount of time. The device will go into alarm before the onset of

symptoms in healthy adults. It is important to have early notification

of a potential hazard, while still having the ability to react in time. In

many reported cases of CO exposure, victims may be aware that

they were not feeling well, but became disoriented and could no

longer react well enough to exit the building or get help.

NOTE:

Healthy adults may not experience any symptoms of CO

exposure when the device alarms, however infants, young children,

pregnant women, elderly people, people with cardiac, respiratory or

other health related issues may be more quickly and severely

affected by CO exposure. If you are experiencing even mild

symptoms of CO poisoning, consult a medical professional

immediately.

Standards:

Underwriters Laboratories, Inc. Single and Multiple

Station carbon monoxide alarms UL 2034. For your information, the

UL 2034 Standard, reads as follows:

Underwriters Laboratories, Inc UL 2034, Section 1-1.2

Carbon

monoxide alarms covered by these requirements are intended to

respond to the presence of carbon monoxide from sources such as,

but not limited to, exhaust from internal-combustion engines, abnor-

mal operation from fuel-fired appliances and fireplaces. CO alarms

are intended to alarm at carbon monoxide levels below those that

could cause a loss of ability to react to the dangers of carbon

monoxide exposure.

Содержание CO1209 SERIES

Страница 1: ...exposed to a critical level of CO measured in parts per million or ppm within a specified time measured in minutes This CO alarm features a permanently installed sensor an indicator light and an 85dBA...

Страница 2: ...other appliances may also prevent alert persons from hearing the alarm horn This device is not intended for people who are hearing impaired CO alarms are not a substitute for life insurance Though th...

Страница 3: ...cupiable level of a dwelling unit including basements excluding attics and crawl spaces 3 Other locations where required by applicable laws codes or standards The installation of additional CO alarms...

Страница 4: ...DO NOT INSTALL THIS CO ALARM In garages kitchens furnace rooms or in any extremely dusty dirty or greasy areas Closer than 15 feet 4 6 meters from a furnace or other fuel burning heat source or fuel b...

Страница 5: ...1125 feet between the first and last CO alarm NOTES ON TANDEM INTERCONNECTING MODELS DO NOT connect Gentex CO alarms to other manufacturers CO alarms No more than 12 Gentex models CO1209 may be tande...

Страница 6: ...to add the telephone numbers of the emergency service provider and a qualified technician Once CO alarm is installed place one 1 label next to the CO alarm and place the other label near the fresh ai...

Страница 7: ...en using any of these materials near the alarm make sure the room is well ventilated The CO alarm is not washable DO NOT submerge the alarm in water Water can affect the sensor causing permanent damge...

Страница 8: ...entex postage prepaid You must also pack the CO Alarm to minimize the risk of it being damaged in transit You must also enclose a return address CO Alarms returned for warranty service should be sent...

Отзывы: