10
The adjustable cartridge used has a 3mm
hole under the indicator on the front of
the handle. The hole has a grub screw for
adjusting the run time.
•
The run time adjustment screw is under
the indicator cap. Remove the indicator
cap and use a 1.5mm allen key to adjust
the timing.
•
Turning the screw clockwise will reduce
the run time.
•
Turning the screw anti clockwise will
increase the run time
Timed Adjustment Range
Contact GENTEC before attempting to change
flow cups.
Warranty may be void if damage to internal
components or spare parts occurs during
service / maintenance.
GPure is available in a range of fixed timing
options which are installed ex-works.
Refer to the chart below:
ADJUSTING CARTRIDGE TIMING (0 TO 20 SECONDS)
Time Adjustment
FCC.
Description
TFT9050
Flow cup 0 - 5 +/-1 Sec
TFT9056
Flow cup 0-20 +/-5 Sec
TFT9054
Flow cup 0-40 +/-10 Sec
For optimum operational life, the installation of a PRV set to 350kPa is recommended