Genquip Gi1000 Digital Inverter Petrol Generator

Activity/Procedure 

If you do this ... 

Potential Hazards

This could happen ... 

Risk 

Corrective Action

You can prevent by ... 

Contact with hot 

surfaces such as 

engine, exhaust 

components. 

Could result in serious burns.

2

During operation, touch only 

the control surfaces. Shutting 

the generator down and letting 

it cool sufficiently.
Keep children away from 

generator during and 

immediately after operation. 

Operating generator 

to close to buildings 

or placing objects 

close to the muffler 

exhaust can cause.

Heat buildup that could cause 

generator to overheat and the 

possibility of fire. Objects close 

to generator may be damaged 

due to close proximity.

2

Ensure that the generator 

is sufficient distance from 

buildings or objects allowing 

heat and exhaust emissions to 

dissipate freely. 

Smoking around the 

generator.

Fire. Explosion. 
Serious Injury.

2

Do not smoke around 

the generator under any 

circumstances.

Operating whilst 

wet or Cleaning the 

generator when in 

operation can cause.

Electrocution.

1

Never operate the generator 

whilst wet or expose to 

damp conditions. Clean the 

generator only when shut 

down and cooled down 

completely. Do not spray 

water directly on or near any 

electrical items. Use a damp 

cloth to Wipe over generator to 

keep clean.

Operating generator 

on an uneven surface 

may cause.

Engine to seize and over heat 

due to improper lubrication. 

Fuel spillage, which may 

cause fire or explosion 

resulting in serious injury. 

2

Always operate generator on a 

level & hard surface.

Moving the generator 

whilst in operation.

Fuel spillage, which may 

cause fire or explosion 

resulting in serious injury.

2

Always shut down generator 

and allow it to cool completely 

before moving.

Transporting 

generator.

Fuel spillage, which may 

cause fire or explosion 

resulting in serious injury. Oil 

spillage, which may cause 

slippage.

2

Ensure fuel tap is switched 

off and the fuel cap is affixed 

firmly. Always transport 

the generator in an upright 

position. If transporting over a 

long distance drain fuel from 

tanks.

Using the incorrect 

fuel &/or oil type. 

Misfiring of engine, which 

may result in engine parts 

separating from main body 

resulting in serious injury.

2

Ensure you check that you 

are using correct oil and fuel 

types.

Содержание Gi1000

Страница 1: ...page 1 Genquip Gi1000 Digital Inverter Petrol Generator Genquip Gi1000 Digital Inverter Petrol Generator Owners Manual ...

Страница 2: ...page 2 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...

Страница 3: ...enance 8 Spark Plugs 9 Engine Oil 10 Air Filter 11 Fuel Tank Filter 11 Spark Arrester 12 Genquip Safety 14 Operating Procedure 15 Visual Inspection Start Up Shutdown Potential Hazards 16 and Risk Assessment Maintaining your 18 Generator Cleaning Storing or Transporting Servicing Specifications 19 Dimensions Troubleshooting 20 Engine Won t Start Generator Won t Produce Power Storage Drain The Fuel ...

Страница 4: ...l 5 Front Side Maintenance Cover 6 Recoil Starter 7 Engine Switch 8 Fuel Drain Hose 1 9 Fuel Drain Hose 2 10 240 Volt Sockets 11 Carry Handles 12 DC Circuit Protector 13 DC Socket 14 Fuel Saver Switch 15 Oil Alert Indicator Light 16 Overload Indicator Light 17 Output Indicator Light 18 AC Socket 19 Ground Earth Terminal 5 8 9 7 6 10 2 11 3 4 1 ...

Страница 5: ... the fuel tank capacity is 2 9 litres Check the Fuel Level 1 Make sure the generator is turned off by rotating the engine switch 7 to the off position Fig D 2 Check the fuel by a visual check Remove the fuel cap and fuel filter screen reviewing the fuel level Fig E 3 If fuel is low replace the filter screen inside the fuel tank neck Fig F 4 Pour in unleaded fuel from an approved fuel container int...

Страница 6: ...stem If the oil level falls below the safe operating level the engine will stop automatically Unless you refill with oil the engine will not start again Note If the engine stalls or does not start turn the engine switch to ON position and then pull the recoil starter If the oil warning light flickers for a few seconds the engine oil is low Add oil and restart DC Protector The DC Protector turns of...

Страница 7: ... 4 To start a cold engine move the choke lever to the start position In order to restart a warm engine leave the choke lever in the run position Fig I 5 Slowly pull the recoil starter 6 until you feel it engage and then pull it briskly Return the recoil starter gently and slowly to the original position by hand NOTE When the motor is started for the very first time it will require a number of atte...

Страница 8: ...reen 4 Recoil Starter Check operation 4 Choke Handle Check operation 4 Fuel System Check hose condition look for leaks 4 4 Fittings Fasteners Check and Tighten 4 4 Cooling System Air Check for obstructions 4 4 Exhaust System Check for obstructions 4 Item First 20 hours then every 50 hours Attention 1 M o n t h o r 2 0 h o u r s P r e o p e r a t i o n D a i l y 3 M o n t h s o r 5 0 h o u r s 6 M ...

Страница 9: ...n deposits using a wire brush 6 Check for discolouration of the top of the spark plug The standard colour should be tan colour 7 Check the spark plug gap Fig T Acceptable gap should be between 0 6mm 0 7mm 8 Install Reinstall the spark plug carefully by hand 9 Once the spark plug has been seated tighten with the spark plug wrench 10 Reinstall the spark plug cap on top of the spark plug 11 Reinstall...

Страница 10: ... oil filler neck 5 Once emptied tilt the generator back up and place into the generator up right position 6 Refill with recommended oil Fill to the upper limit of the filler neck Fig W NOTE The recommended 4 stroke engine oil is 10W30 multi viscosity 4 stroke oil CAUTION Check that no foreign material debris dust enters the crankcase 7 Reinstall the oil filler cap CAUTION Be sure to install secure...

Страница 11: ...ALWAYS keep the filter clean at all times Fuel Tank Filter 1 Remove the fuel tank cap and filter 2 Clean the filter with solvent if damaged replace 3 Wipe the filter and insert it WARNING Be sure the tank cap is securely tightened Air Filter Maintainence 1 Remove side cover 2 Unscrew bolts 3 Remove air filter cover 4 Remove foam air filter 5 Clean filter in foam filter cleaner or kerosene and dry ...

Страница 12: ...ficult If the engine has been running the muffler and the spark arrester will be very hot Allow the muffler to cool before cleaning the spark arrester How to remove the Spark Arrester 1 Remove 4 bolts from the muffler cover Fig i 2 Remove the muffler cover Fig ii 3 Remove the special screw from the spark arrester Fig iii 4 Remove the spark arrester from the muffler Fig iv 4 Clean the spark arreste...

Страница 13: ...page 13 Genquip Gi1000 Digital Inverter Petrol Generator Spark Arrester Maintenance Figure i Figure ii Figure iii Figure v Figure iv ...

Страница 14: ...in a well ventilated area Keep all flammable materials and fuel away from the operating generator Caution of the hot exhaust must be observed as a generator can easily start a fire always locates your generator where its exhaust will vent safely Avoid getting burned Many generator parts radiate heat that is sufficient to burn you during operation Only a licensed electrician should hard wire your G...

Страница 15: ...uel level Air filter is not dusted and is free of debris Generator grounded Fuel cap on Start up Disconnect any electrical devices from the generator Generator is on a level surface Exhaust is free from obstructions Fuel shut tap is on Always use fresh fuel Engine switch is in the on position Choke is in the open position Return choke to the closed position once running petrol model only Shutdown ...

Страница 16: ...pen fuel cap slowly Do not over fill fuel tank If fuel spillage has occurred during refueling clean the spillage completely and allow sufficient time for any fuel vapors to dissipate Tampering with the factory preset engine settings Generator could over heat and engine could over speed which may result in a fire causing injury 2 Never attempt to tamper with factory settings if in doubt contact Gen...

Страница 17: ...lectrocution 1 Never operate the generator whilst wet or expose to damp conditions Clean the generator only when shut down and cooled down completely Do not spray water directly on or near any electrical items Use a damp cloth to Wipe over generator to keep clean Operating generator on an uneven surface may cause Engine to seize and over heat due to improper lubrication Fuel spillage which may cau...

Страница 18: ...w pressure air or vacuum system CAUTION DO NOT use a forceful spray of water to clean the generator Water can penetrate generator s electrical system which could reduce insulation resistance Possible generator failure may result Storing or Transporting Turn fuel tap off Storage Petrol models drain carburettor and fuel tank Servicing First service 20 hours Service intervals thereafter 50 hours If o...

Страница 19: ...0 Watts MAX OUTPUT 1000 Watts RUN TIME AT 1 2 RATED LOAD 7 hours RUN TIME AT RATED LOAD 4 5 hours RATED VOLTAGE 240 V RATED FREQUENCY 50 Hz RATED CURRENT 3 9A DC OUTPUT 12V 5A ENGINE TYPE 143F OHV AIR COOLED 4 STROKE STARTING SYSTEM RECOIL START CYLINDER ARRANGEMENT INCLINED SINGLE CYLINDER BORE X STROKE 43 5mm X 36mm IGNITION SYSTEM Full Transitor SPARK PLUG TYPE CR7HSA NGK GAP 0 6 0 7mm DISPLACE...

Страница 20: ...from the carburettor by loosening the drain screw on the carburettor float chamber 3 Turn the fuel cock lever to OFF Start the engine and leave it run until it stops This will burn any remaining fuel in the carburettor Engine 1 Remove the spark plug pour about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug Turn over engine several times with ig...

Страница 21: ...may be flooded Leave the generator rest for 5 10 minutes and then try again following the instructions when doing so Alternatively if the choke lever is in full choke position start switch the choke to the run position and try to re start Old Fuel Remove the existing fuel and replace with new fuel AC power supply No electrical output Faulty receptacle Have service center replace receptacle Is the ...

Страница 22: ...lied DC cables with the actual generator Mixed polarity Check to make sure that the DC cables are connected to the correct battery polarity terminals That is positive to positive and negative to negative Generator overheating Generator overloaded Reduce load Insufficient ventilation Move to adequate supply of fresh air Generator stops Generator may have fallen over Check to make sure that the gene...

Страница 23: ...n Generator air filter may need cleaning Remove the air filter Check to make sure that the air filter is clean If required clean dry and re install the air filter Generator fuel filter may be blocked The internal in line filter may be blocked Contact your service agent for a service replacement of the fuel filter Generator running rough Has the choke been elevated to the Run position Check to make...

Страница 24: ...page 25 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...

Страница 25: ...page 26 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...

Страница 26: ...page 27 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...

Страница 27: ...page 28 Genquip Gi1000 Digital Inverter Petrol Generator www genquip com au Genquip Warehouse 45 Riverside Road Chipping Norton NSW Call 1300 730 716 ...

Отзывы: