5.4 LCD SETTING
After press function button, the unit will enter setting mode. Set password:1155
Button Function
Illustrate
Diagra
m
Main
Display
Interface
Return to the default display screen
Set up
Language
Chinese: Chinese display
English: English Display
Working
mode
AC:
(default) AC will provide power to the load as the first priority,solar
charging the battery. When solar energy is insufficient,AC and solar
energy charge the battery at the same time. When AC is unavailable it
will be powered by solar energy or batteries.
Solar:
Solar energy provides power to the loads as the first priority.
When the solar energy is sufficient,the extra energy will charges the
battery. When solar energy is insufficient for load,batteries and solar
will supply power at the same time. When solar energy and batteries
are insufficient or solar energy is unavailable,AC power supply power
to the load.
Battery:
Battery provides power to the loads as the first priority. AC
provides power to the loads when battery voltage drop to low-level
warning voltage or setting point,and the AC power will charge the
battery. When the battery is fully charged,battery provides power to the
load again.
Solar + AC:
Solar energy provides power to the load as the first priority.
If solar energy is not sufficient to power all load,AC energy will supply
power the load at the same time