Genius SPRINT 05 SW Скачать руководство пользователя страница 9

SPRINT 05 SW

ENGLISH

Guide for the installer

Page 10

5.3.3. l

ine

Terminals “

N

 & 

F

”. These terminals are for connecting the 230/115 V~ power supply line.

5.3.4. e

Arthing

.

Terminal “

PE

” This terminal is for connecting the unit earthing wire. Connect the network line earthing wire to the terminal with the 

corresponding symbol.

  This connection is absolutely required for correct operation of the unit.

6. INSERTING THE REMOTE CONTROL RECEIVER BOARD (Fig. 4)

The unit is designed to house a 5-pin radio-receiver module. To install, cut off electrical power and insert the module in the provided 

connector 

CN4

 (see Fig.1) on the unit.

  In order not to damage, and therefore irreparably compromise its operation, the receiver must be connected in the direction 

shown in Fig.2

Then follow the instructions supplied with the radio-receiver for memorising the remote control.

7. SETTING THE OPERATING PARAMETERS

All the programmable functions of the board are set using dip-switch 

DP1

 (see Fig.1). The different options are listed in the diagram below.

OPERATING LOGIC

Manual logic

Automatic logic with a 15-second pause.

Automatic logic with a 20-second pause.

Automatic logic with a 40-second pause.

CONDO FUNCTION

Condo function disabled

Condo function enabled. During the opening phase, it ignores any further OPEN pulses.

OPEN A INPUT OPERATION

Opens, closes, opens, closes, ...

Opens, stops, closes, stops, opens, stops, ....

PHOTOCELL OPERATION

The connected safety switches are active only during the gate closing movement

The connected safety switches are active both during the gate closing and opening movement.

ENCODER

Gate operation without the encoder

Gate operation with the encoder

ELECTRONIC CLUTCH SENSITIVITY (active only with the encoder connected and activated)

High, more sensitive to the obstacle

Medium-high

Medium-low

Low, less sensitive to the obstacle

  Use the dip-switches only after having cut off power. Otherwise unit operation can be compromised

Содержание SPRINT 05 SW

Страница 1: ...SPRINT 05 SW ISTRUZIONI PER L USO INSTRUCTIONS FOR USE INSTRUCTIONS POUR L USAGER INSTRUCCIONES PARA EL USO GEBRAUCHSANLEITUNG GIDS VOOR DE GEBRUIKER...

Страница 2: ...ed with an intrinsic anti crushing safety device consisting of a torque control Nevertheless its tripping threshold must be checked as specified in the Standards indicated at point 10 16 The safety de...

Страница 3: ...n zu berpr fen 16 Die Sicherheitsvorrichtungen Norm EN 12978 erm glichen den Schutz eventueller Gefahrenbereiche vor mechanischen Bewegungsrisiken wie zum Beispiel Quetschungen Mitschleifen oder Schni...

Страница 4: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 1 Fig 1...

Страница 5: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 2 Fig 2 Fig 3 Fig 2...

Страница 6: ...requirements of the following EEC directives 2006 95 EC Low Voltage directive 2004 108 EC Electromagnetic Compatibility directive Additional information This product underwent a test in a typical uni...

Страница 7: ...lose time 120 sec Pause time Four pre set levels Motor power Adjustable using a trimmer Terminal board inputs Open A Open B Stop Limit switch when opening Limit switch when closing Photocells Power Te...

Страница 8: ...mally closed contact To these terminals connect any safety device push button key switch etc that must stop gate movement by disabling all automatic functions The gate should resume the memorised cycl...

Страница 9: ...E OPERATING PARAMETERS All the programmable functions of the board are set using dip switch DP1 see Fig 1 The different options are listed in the diagram below OPERATING LOGIC Manual logic Automatic l...

Страница 10: ...sted using dip switches 7 8 see paragraph 7 Important Use of the encoder does not substitute the limit switches which are mandatory 9 ADJUSTING THE MOTOR POWER The motor power can be adjusted in two w...

Страница 11: ...en B Stop Safety devices at closing Safety devices at closing and opening Closed Opens the gate Opens the gate for 8 seconds If enabled disables the OPEN commands If enabled disables the OPEN commands...

Страница 12: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 37...

Страница 13: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 38...

Страница 14: ...momento y sin comprometerse a poner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car ct...

Отзывы: