![Genius SPRINT 05 SW Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/genius/sprint-05-sw/sprint-05-sw_instructions-for-use-manual_2212749009.webp)
SPRINT 05 SW
ENGLISH
Guide for the installer
Page 10
5.3.3. l
ine
Terminals “
N
&
F
”. These terminals are for connecting the 230/115 V~ power supply line.
5.3.4. e
Arthing
.
Terminal “
PE
” This terminal is for connecting the unit earthing wire. Connect the network line earthing wire to the terminal with the
corresponding symbol.
This connection is absolutely required for correct operation of the unit.
6. INSERTING THE REMOTE CONTROL RECEIVER BOARD (Fig. 4)
The unit is designed to house a 5-pin radio-receiver module. To install, cut off electrical power and insert the module in the provided
connector
CN4
(see Fig.1) on the unit.
In order not to damage, and therefore irreparably compromise its operation, the receiver must be connected in the direction
shown in Fig.2
Then follow the instructions supplied with the radio-receiver for memorising the remote control.
7. SETTING THE OPERATING PARAMETERS
All the programmable functions of the board are set using dip-switch
DP1
(see Fig.1). The different options are listed in the diagram below.
OPERATING LOGIC
Manual logic
Automatic logic with a 15-second pause.
Automatic logic with a 20-second pause.
Automatic logic with a 40-second pause.
CONDO FUNCTION
Condo function disabled
Condo function enabled. During the opening phase, it ignores any further OPEN pulses.
OPEN A INPUT OPERATION
Opens, closes, opens, closes, ...
Opens, stops, closes, stops, opens, stops, ....
PHOTOCELL OPERATION
The connected safety switches are active only during the gate closing movement
The connected safety switches are active both during the gate closing and opening movement.
ENCODER
Gate operation without the encoder
Gate operation with the encoder
ELECTRONIC CLUTCH SENSITIVITY (active only with the encoder connected and activated)
High, more sensitive to the obstacle
Medium-high
Medium-low
Low, less sensitive to the obstacle
Use the dip-switches only after having cut off power. Otherwise unit operation can be compromised
Содержание SPRINT 05 SW
Страница 4: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 1 Fig 1...
Страница 5: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 2 Fig 2 Fig 3 Fig 2...
Страница 12: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 37...