background image

9

ENGLISH

Manually move the leaf to its open position.

Lay the first element of the rack on the pinion, on the first spacer (fig. 

10).

Secure the rack element to the leaf with a clamp (fig. 10).

Manually slide the leaf toward the closing point until you reach the rack’s 

third spacer, and fix it with a weld spot.

Definitively weld the three spacers on the gate. Procedure for correctly 

fixing the other rack elements required to reach the closing position:

Bring near another rack element to the last fixed element, using a piece 

of rack to synchronise the teeth with the two elements (fig. 11).

Manually slide the leaf toward the closing point until you reach the pinion 

with the third spacer of the element to be secured (fig. 11).

 Make sure that all the rack elements work on the centre of the pinion’s 

teeth. Otherwise, adapt the gearmotor’s position.

Weld the element’s three spacers (fig. 10).

  a) Do not, on any account, weld the rack elements either to the 

spacers or to each other.

 

  b) Do not, on any account, use grease or other lubricants between 

rack and pinion.

3.

4.

5.

6.

7.

8.

9.

10.

Fig. 9

Fig. 9

Fig. 10

Fig. 10

Fig. 11

Fig. 11

To obtain correct play between rack and pinion, lower the gearmotor by 

1.5 mm, using the nuts supporting the foundation plate. When you have 

finished adjusting, correctly tighten the operator securing nuts.

 If the gate was recently built, check this play (fig.2) a few months 

after installation. 

Manually check if the gate is free to open completely and if leaf move-

ment is good and friction- free.

3.4. POSITIONING THE STROKE-LIMIT MAGNETS

The operator has a magnetic limit-switch, which commands gate motion 

to stop when the magnet, which is secured to the upper part of the rack, 

activates the sensor. The magnets supplied with the operator are specifically 

polarised and activate only one of the sensor’s contacts: the closing or 

opening contact. The magnet activating the open gate contact bears an 

open padlock symbol, and, vice versa, the magnet activating the closed 

gate contact bears the closed padlock symbol (see Fig. 13).

Procedure for a correct positioning of the two stroke-limit magnets:

Assemble the two magnets as shown in figure 13.

Set  the  operator  to  manual  mode  operation  -  see  chapter  6  -  and 

power up the system.

Manually take the gate to opening position, leaving about 40 mm from 

the opening mechanical stop.

Allow the magnet, with the padlock open, to slide on the rack in opening 

direction - see figure 14. As soon as the LED on the board, referring to the 

opening limit-switch, goes OFF, take the magnet forward by another 10 

mm and fasten it provisionally with the appropriate screws.

Repeat the operations from point 3 for the closing magnet.

Re-lock the system (see paragraph 6).

 before sending a pulse, make sure that the gate cannot be moved 

manually.

Command  a  complete  gate  cycle  to  check  if  the  limit-switches  are 

operating correctly.

11.

12.

1.

2.

3.

4.

5.

6.

7.

1.5

mm
1.5

mm

Fig. 12

Fig. 12

Fig. 13

Fig. 13

Отзывы: