background image

FEATURES 

Uses AC power to power equipment that requires 10~16V DC power. 

Converts standard AC(110~130V AC) household power to an adjustable 10~16V 

DC power, and supplies up to 100 amps of continuous power. 

Note: A normal vehicle's electrical system provides around 13.8 Volts when the 

engine is running. 

Is a versatile piece of equipment that can be used in several applications such 

as retail audio displays, show cars, and test benches. 

Features include: 

•Adjustable regulated output voltage 10~16V 

•Up to 100 amp output current 

•Cooling fans 

•Thermal overload shut off protection 

•Current overload shut off protection 

•Combo output connectors act as both binding posts and banana plug terminals 

•Pulse charging to inhibit battery sulfation 

IMPORTANT SAFETY INSTRUCTIONS 

This manual contains important safety and operating instructions. 

To reduce the risk of fire, electric shock, and injury to person or equipment; 

carefully read the following before you use the power supply. Please read all 

cautionary markings on the product that you will connect to the power supply. 

WARNINGS: 

•This product is not recommended for outdoor use. 

•Do not expose the power supply to excessive moisture. 

•This product is not intended to be used as a stand alone battery charger. lt is 

designed for the purpose of providing supplemental power when a DC power 

generator isn't available. 

•Do not connect the a battery that is deeply discharged. The initial high level of 

current draw will force the power supply into current limit mode for prolonged 

periods. This type of use is harmful to the power supply. 

•When used as a supplemental power supply will not damage connected batter-

ies. When a connected battery reaches a fully charged state will decrease its 

output current to a safe level by degree. 

•Should not be left connected to batteries for extended unattended periods of 

time. This could result in damage to the connected batteries. 

•Make sure the power supply is securely mounted to avoid injury or damage to 

the unit. 

•The power supply should be operated only from a standard AC outlet that 

provides (110V AC/60Hz), as indicated on the label. 

•Do not overload AC power outlets to avoid danger of electric shock and fire. A 

minimum current of 10A(20A) will be required. 

•Avoid using extension cords. 

•The power plug is polarized for safety. Do not defeat the ground feature. 

•Do not block or cover the power supply's cooling fan openings to avoid 

overheating. 

•Unplug the power supply during lightning storms to avoid power surge damage. 

•If your unit should require service or new parts contact the manufacturer. Do 

not attempt to service the unit. 

CONNECTIONS 

CAUTION: Make all connections before you connect the power supply to 

AC Power. 

1. Turn off the device requiring power. 

2. Set the Power Switch to off. 

3. Set the correct output voltage for the device being connected. 

4. Turn the sleeves of the red and black binding output posts counterclockwise 

to expose the wire hole. 

5. Insert the device's positive wire into the red binding post wire hole,then tight-

en the binding post sleeve to secure the wire in place. 

6. Insert the device's negative wire into the black binding post wire hole, then 

tighten the binding post sleeve to secure the wire in place. 

7. If you are using a banana plug style connector, simply insert the plugs into the 

corresponding positive and negative terminal jacks. 

To avoid risk of damage to both the power supply and the connected device: 

•Verify and follow the correct polarity when connecting the power supply to the 

device 

•Do not let the ends of the positive and negative wires touch each other 

•The binding post wire holes can accommodate up to 14 gauge wire 

8. Connect the AC cord to a standard (110~130V AC) outlet. 

9. High voltage protection: When the output voltage exceed 17V DC, the power 

supply turn into protection, giving no output. The blue and red LED light on 

when. 

10. Temperature controlled fans: The Power supply will give out different 

amount of heat when use in different level. The fans run at speeds accordingly 

to regulate temperature. The fans stay off when the surface temperature of the 

unit remain below 50°C.When the controlled circuit sense a temperature above 

50°C, the fans start to turn at high speed to bring out hot air. When the surface 

temperature exceed 75°C, the thermal protection trigger, the fans will stop 

running, and the blue and red indicator will light on. The unit come back to work 

only after the surface temperature drop to 68°C. 

11. Power supply linkable function: 

A. the cable of connection, It is used in application when multiple power supply 

are linked together to provide higher output 

B. the master and slave switch, The output voltage of all linked power supply is 

universally controlled by the master unit.

OPERATION 

To use the after you have correctly connected a device to it, flip the power switch 

to the on position. The blue LED should illuminate indicating the unit is on. 

If the blue LED does not illuminate check all connections. If all connections are 

good turn the unit off and confirm the wall AC outlet has power. If the outlet has 

power disconnect the power supply from the device then turn the power supply 

on again. If the power supply now operates normally verify the connected 

device does not require more than 100 amps of current which will cause the to 

go into protection. 

Your power supply might cause TV or FM radio interference. To determine 

whether your power supply is causing interference, simply turn off your power 

supply. If the interference goes away, your power supply is causing it. Try 

moving your power supply away for the affected source. 

Example: Using a single with multiple batteries 

Fuse all connected devices as recommended by the manufacturer. 

Notes: 

1. In single unit application, master mode should be selected. In situation when 

slaved is wrongly selected the output will give 17V DC, which will trigger high 

voltage protection. When this happens, slide the switch to master and restart 

the unit. 

2. In multiple unit application, make sure all power supplies are properly linked 

by connecting cable. In order to work, there must be one unit selected as master 

output controlled unit. 

3. Only the unit with Master selected is able to control the output. 

Example: Using multiple parallel with multiple batteries 

Fuse all connected devices as recommended by the manufacturer. 

Up to four can be connected in parallel.When using in parallel configuration, 

adjust all connected units to the same output voltage.The maximum available 

current will be determined by the sum of the rated capacity of each in the circuit. 

In the example below the four parallel units of will supply about 400A of current. 

WARNING: Do not overload AC power outlets to avoid danger of electric shock 

and fire. A minimum current of 20A per will be required. Avoid connecting multi-

ple power supplies to a single AC outlet using power strips. 

SPECIFICATIONS 

AC 110V-130V 

Input Voltage    

120V Ac±10% 

Input Frequency  

60Hz 

Adjustable Output  

10V-16V DC±0.5Volts 

Output Current  100 Amps DC Continuous(Maximum) 

Line Regulation   

Less Than ±5% 

Load Regulation   

Less Than ±5% 

Efficiency More  Than 85% 

Overload Protection   FUSE 20A/250V(Input Voltage:120V) 

Output Ripple    

150 mV RMS 

Design   

Switching Type 

Protection Temperature 75°C 

Cooling Fan    

4PCS(40*40*10MM) 

Input Cable  

 

SVT 14 AWG 

Power Switch    

15A/250V AC 

Dimensions (WHD)  

262.4x67x247mm 

Specifications are typical; Individual units might vary. 

Specifications are subject to change and Improvement without 

notice. 

ESPECIFICACIONES

AC 110V-130V

Voltaje de entrada  

120V Ac ± 10%

Frecuencia de entrada   60Hz

Salida ajustable    

10V-16V DC ± 0.5Volts

Corriente de salida  

100 amperios CC continuo (máximo)

Regulación de línea  

inferior a ± 5%

Regulación de carga  

menor que ± 5%

Eficiencia  

 

más del 85%

Protección contra sobrecarga FUSE 20A / 250V (Voltaje de entrada: 120V)

Ondulación de salida  

150 mV RMS

Diseño de tipo de  

conmutación

Temperatura de protección 75 ° C

Ventilador  

 

4PCS (40 X 40 X 10MM)

Cable de entrada  

SVT 14 AWG

Interruptor de encendido   15A / 250V AC

Dimensiones (WHD)  

262.4x67x247mm

Las especificaciones son típicas; Las unidades individuales pueden 

variar. Las especificaciones están sujetas a cambios y mejoras sin previo 

aviso.

User Manual / Manual del Usuario

www.geniuscaraudio.com

ESP

AÑOL

ENGLISH

GFC-100A-16

Power Supply 

Adjustable Voltage

FONT

CHARGER

Содержание GFC-100A-16

Страница 1: ...User Manual ManualdelUsuario www geniuscaraudio com ESPAÑOL ENGLISH GFC 100A 16 PowerSupply AdjustableVoltage FONT CHARGER ...

Страница 2: ...he power supply Please read all cautionary markings on the product that you will connect to the power supply WARNINGS This product is not recommended for outdoor use Do not expose the power supply to excessive moisture This product is not intended to be used as a stand alone battery charger lt is designed for the purpose of providing supplemental power when a DC power generator isn t available Do ...

Страница 3: ...oling fan openings to avoid overheating Unplug the power supply during lightning storms to avoid power surge damage If your unit should require service or new parts contact the manufacturer Do not attempt to service the unit CONNECTIONS CAUTION Make all connections before you connect the power supply to AC Power 1 Turn off the device requiring power 2 Set the Power Switch to off 3 Set the correct ...

Страница 4: ...vel The fans run at speeds accordingly to regulate temperature The fans stay off when the surface temperature of the unit remain below 50 C When the controlled circuit sense a temperature above 50 C the fans start to turn at high speed to bring out hot air When the surface temperature exceed 75 C the thermal protection trigger the fans will stop running and the blue and red indicator will light on...

Страница 5: ...mmended by the manufacturer Notes 1 In single unit application master mode should be selected In situation when slaved is wrongly selected the output will give 17V DC which will trigger high voltage protection When this happens slide the switch to master and restart the unit 2 In multiple unit application make sure all power supplies are properly linked by connecting cable In order to work there m...

Страница 6: ...rmined by the sum of the rated capacity of each in the circuit In the example below the four parallel units of will supply about 400A of current WARNING Do not overload AC power outlets to avoid danger of electric shock and fire A minimum current of 20A per will be required Avoid connecting multi ple power supplies to a single AC outlet using power strips Slave Master Mode Master Mode Slave Master...

Страница 7: ...ect to change and Improvement without notice ESPECIFICACIONES AC 110V 130V Voltaje de entrada 120V Ac 10 Frecuencia de entrada 60Hz Salida ajustable 10V 16V DC 0 5Volts Corriente de salida 100 amperios CC continuo máximo Regulación de línea inferior a 5 Regulación de carga menor que 5 Eficiencia más del 85 Protección contra sobrecarga FUSE 20A 250V Voltaje de entrada 120V Ondulación de salida 150 ...

Страница 8: ...oducto que conectará a la fuente de alimentación ADVERTENCIAS Este producto no está recomendado para uso en exteriores No exponga la fuente de alimentación a una humedad excesiva Este producto no está destinado a ser utilizado como un cargador de batería independiente Está diseñado con el propósito de proporcionar energía suplementaria cuando un generador de energía CC no está disponible No conect...

Страница 9: ...durante las tormentas eléctricas para evitar daños por sobretensiones Si su unidad necesita servicio o piezas nuevas póngase en contacto con el fabrican te No intente reparar la unidad CONEXIONES PRECAUCIÓN realice todas las conexiones antes de conectar la fuente de alimentación a Alimentación AC 1 Apague el dispositivo que requiere energía 2 Ajuste el interruptor de encendido en apagado 3 Configu...

Страница 10: ... de alimentación emitirá una cantidad de calor diferente cuando se use a diferentes niveles Los ventiladores funcionan a velocidades acordes para regular la temperatura Los ventiladores permanecen apagados cuando la temperatura de la superficie de la unidad perman ece por debajo de 50 C Cuando el circuito controlado detecta una temperatura superior a 50 C los ventiladores comienzan a girar a alta ...

Страница 11: ...ada Ejemplo usar una sola con varias baterías Fusione todos los dispositivos conectados según lo recomendado por el fabricante Notas 1 En la aplicación de una sola unidad se debe seleccionar el modo maestro En una situación en la que el esclavo está seleccionado incorrectamente la salida dará 17 V CC lo que activará la protección de alto voltaje Cuando esto suceda deslice el interruptor hacia el m...

Страница 12: ...e la capacidad nominal de cada uno en el circuito En el siguiente ejemplo las cuatro unidades paralelas suministrarán aproximadamente 400 A de corriente ADVERTENCIA No sobrecargue las tomas de corriente de CA para evitar el peligro de descargas eléctricas y fuego Se requerirá una corriente mínima de 20 A por persona Evite conectar múltiples fuentes de alimentación a una sola toma de CA con regleta...

Отзывы: