Operator's Manual
Second Edition • Second Printing
24
Z-40/23N • Z-40/23N RJ
Part No. 1258834
Inspections
At the Platform Controls
11 Turn the key switch to platform control.
12 Pull out the red Emergency Stop button to the
on position.
Result:
SYSTEM
READY
will appear on the LCD
display screen.
Test Emergency Stop
13 Push in the platform red Emergency Stop button
to the off position.
Result: The LCD display screen will be blank.
14 Test each machine function.
Result: All functions should not operate.
15 Pull out the red Emergency Stop button.
Test the Horn
16 Push the horn button.
Result: The horn should sound.
Test the Foot Switch
17 Do not press down the foot switch. Test each
machine function.
Result: The machine functions should not
operate.
Test Machine Functions and Descent Alarm
18 Press down the foot switch.
19 Activate each machine function control handle
or toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
should sound while the boom is lowering.
Test Machine Functions and Descent Alarm
6 Do not hold the function enable switch to either
side. Attempt to activate each boom and
platform function toggle switch.
Result: All boom and platform functions should
not operate.
7 Hold the function enable switch to
either side and activate each boom
and platform function toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
should sound while the boom is lowering.
Test the Tilt Sensor
8 Pull out the platform red Emergency Stop button
to the on position. Turn the key switch to
platform control.
9 Open the turntable cover on the
side opposite the ground controls
and locate the tilt sensor.
10 Press down one side of the tilt
sensor.
Result: The alarm, located in the
platform, should sound.