![Genie TPIR-607 Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/genie/tpir-607-series/tpir-607-series_instruction-manual_2212479004.webp)
PART DESCRIPTION / POWER CONNECTION
9. Thermostat Switch
:
Turn on at 28
゚
C and turn off at 18
゚
C
16. OUTPUT_2 :
To power supply unit .
17. VR :
To adjust the Infrared LED activation level.
8. Blower and Blower Bracket
10. Video Input BNC Male Connector :
Connect to camera.
11. Video Out BNC Female Connector :
Connect to monitor.
12. Terminal Board
13. Fuse Holder :
With 250V/ 5.0A fuse .
14. AC IN Terminal block :
AC 90~240V external power input
.
15. OUTPUT_1 Spare Terminal Block :
For
AC 24V or
AC 90~240V Camera use .
Note: When using two-cord power cable, please connect them to “Live” and “Neutral”
L E N
External Power Input Connection
:
Live (Brown Wire)
Earth (Yellow/Green Wire)
Neutral (Blue Wire)
4
18. Thermostat Switch :
Turn on at 35
゚
C and turn off at 25
゚
C for Blower.
19. Ground Wire:
To top cover.
20. DC 12V Power-in Jack:
For DC12V Camera use.
21. D/N trigger signal:
To control the color/mono switching of D/N camera.
*IMPORTANT NOTE*
A: If IR trigger signal is on the high position
(+5Vdc), connect the Red and Black wire to D/N
trigger line +/- of camera
B: If IR trigger signal is on the Low position
(+0Vdc), connect the Orange and Black wire to
D/N trigger line +/- of camera.
Red wire:+5Vdc
Orange wire: 0Vdc
Black wire: Ground
1. If you use other D/N Cameras, please refer to the wiring diagram as below.