background image

9a.

   Use garage pre-wiring if available. Otherwise, route wire 

(M) from powerhead to the desired location for the wall 

control. Secure wire with insulated staples (green bag).

9b.   on the powerhead: insert wire down through 

the control wire tube. 

Remove 1/4" insulation from 

white and striped wire. 

Using a small flat head 

screwdriver, press in the orange tab and insert 

the white wire in terminal 3 and the striped wire 

in terminal 4. 

Ensure the wires are secure in each 

terminal, adjust as necessary.

9c.

  

at the wall console end of the wire, remove 1/4" 

insulation from  

the white and striped wires and secure the white wire to the "W" 

terminal and the striped wire to the "B/W" terminal as shown. 

Ensure 

the wires are secure at each terminal, adjust as necessary.

9d.

   Mark the wall console mounting holes, drill 3/32" pilot holes and mount  

with #6 x 1-1/4" screws (provided). If mounting to drywall, anchors will be 

required 

(not provided)

.

9e.

   Post the "ENTRAPMENT WARNING LABEL" (Included in the  

Operation and Maintenance Manual) next to the wall console.

 

• read all stePs BeFore ProCeedInG

8a.

   Position  Safe-T-Beam

®

 (STB) source and sensor on each 

side of garage door 5"-6" above floor. Face the lenses 

toward each other, as shown.

8b.

   Mark bracket mounting holes; drill 3/32" pilot holes and 

secure with (4) 1/4" x 1-1/4" lag screws (provided) into 

wood. If mounting into concrete or block, other fasteners 

are required and are available at leading retail stores.

8c.

   Use garage pre-wiring if available. Otherwise,  

route 2 lengths of wire (M) from powerhead, along the 

rail, across the header and down both sides of 

the door, to each sensor. Secure the wire to the 

rail using the wire clips in the orange bag, evenly 

spaced along the rail. Then use the insulated 

staples in the green bag to secure each wire to 

the wall.

8d.   on the powerhead, insert both wires down 

through the control wire tube. 

Remove 1/4" 

insulation from both sets of white and striped 

wire. Twist two white wires together.

 Using a 

small flat head screwdriver, press in the 

orange tab at terminal 1 and insert the 

wires. 

Twist the two striped wires together and  

insert into terminal 2. Ensure the wires are in  

their terminal, adjust as necessary.

8e.

   At each sensor, remove 1/4" insulation from  

the white and striped wires and secure in  

each terminal. Ensure the wires are secure at  

each terminal; adjust as necessary.

C AU T I O N

When using insulated staples, make only snug enough to hold electrical wire in place. Staples too tight can 

cause damage to wire and cause Safe-T-Beam

®

 System to malfunction.

6” max

5” min

abo

ve floor

6” max

5” min

abo

ve floor

Floor mount option

Sensor

Sensor

Wall mount

Wall mount

8a

WA R N I N G

Use of any other wall control can cause unexpected operation of the door and loss of lighting feature. 

Locate wall console within sight of door and far enough from door to prevent contacting it while operating 

the console. Control must be at least 5 feet above floor to prevent small children from operating it. 

W A R N I N G

Sensor

Powerhead

e

Source

M

Wire clips here

Insulated 

staples here

8c

TOP VIEW

Control 

wire tube

I

Control 

wire tube

BOTTOM VIEW

AC Powered Models

DC Powered Models

8d

To sensors

1

To sensors

2

3 4

1 2

3 4

Sensor/Source

T

8e

O

9c

To wall 

console

AC Powered Models

To wall 

console

DC Powered Models

 

B/W

W

White

Striped

To powerhead

1 2 3 4

1 2 3 4

I

9b

Control

wire

tube

To wall 

console

To wall 

console

note

If pre-wiring is used, ensure that after power is applied to the powerhead (in Step 11), the wall console and  

Safe-T-Beam

®

 LEDs come on. This confirms the wiring is correct. If not, you may need to individually wire each  

Safe-T-Beam

®

 and wall console at the powerhead.

InstAllIng sAFe-t-beAm

® 

(YelloW BaG)

InstAllIng WAll Console

Содержание Screw Drive Models

Страница 1: ...as wood block steel brackets cables or other like items Repairs and adjustments must be made by a trained door system technician using proper tools and instructions WARNI N G An Electrical Shock could...

Страница 2: ...BAG BAG YELLOW BAG Cotter pin x2 Clevis pin x2 Clevis pin long 5 16 x 1 3 4 Lag screw x2 8 3 4 Self tapping screw x2 1 4 x 3 4 Insulated staple x30 5 16 x 1 3 4 Lag screw x2 5 16 18 3 4 Bolt x2 1 4 x...

Страница 3: ...to place 1f Secure screw drives of each section with 2 collars and 2 clips If necessary press down on shuttle carriage and then push screw in end rail section C to mate with screw in middle rail secti...

Страница 4: ...e door is raised 4 With a tape measure determine the distance from the highest point of door travel to the floor 3b Place a mark on the header at the highest point of door travel preferably at the cen...

Страница 5: ...ross piece with 5 16 18 bolts and nuts notsupplied 5c Raise powerhead unit so that there is sufficient clearance between door and rail Cut or bend mounting straps as needed to align with the powerhead...

Страница 6: ...ollers 6a 7a Secure emergency release cord L to shuttle J in rail Secure release handle in orange bag to opposite end of cord L 7b Using the emergency release cord disengage the shuttle and move it to...

Страница 7: ...he green bag to secure each wire to the wall 8d On the powerhead insert both wires down through the control wire tube Remove 1 4 insulation from both sets of white and striped wire Twist two white wir...

Страница 8: ...formedbyalicensedelectricianusingpropertoolsandinstructions 10a Install light bulbs into powerhead I NOTE DONOTexceedmaximumwattage Eachlightbulbshouldbenomorethan100W Model2562requires lightbulbsofno...