Service and Repair Manual
September 2018
Control System Fault Codes
102
S
®
-60 XC
™
• S
®
-65 XC
™
Part No. 1288652GT
ID
Component ID Name
Cause
Effect
Solution
24
Boom Angle
Sensor
13 No signal
No CAN
messages have
been received by
the TCON from
the Angle Sensor.
Boom Up,
Extend and
Turntable
Rotate
functions will
not operate.
* Verify sensor power P85PWR (GR,
TCON J6-7) is at 12 V while the system is
running.
* Verify the sensor is receiving power.
Unplug the sensor and verify 12 V across
pins 2 (+) and 1 (-) on the harness
connector.
* Verify the CAN bus wiring. With the
sensor still unplugged, measure resistance
across harness connector pins 3 and 4. If
resistance is not between 55 and 65 ohms,
check CAN
wire harnesses.* Replace sensor if
necessary.
17 Invalid
calibration
Sensor has been
replaced and
requires
calibration, or
calibration in
memory has been
erased.
Run the boom angle calibration process
and verify fault is no longer active.
19 Out of
range
Sensor disagrees
with boom
position sensed
by LST3S, or
boom exceeded
the calibrated
minimum or
maximum values.
* Run the boom angle calibration process
and verify fault is no longer active.
* If fault persists, verify LST3S (C68LS,
RD, TCON J7-3) operates properly. The
signal should be 12 V when the boom is
stowed and 0 V when the boom is up.
36 Internal
check
The two internal
sensing channels
inside the Angle
Sensor have
registered a
significant
difference.
* Run the boom angle calibration process
and verify fault is no longer active.
* If fault persists, replace the sensor.
25
Cable
tension
21 Loose cable Boom cable
tension limit
switch LSB2S
indicates that the
tension is loose
on the boom
cables.
Boom Up
and Extend
functions will
not operate.
* Return boom to stowed position as
quickly as possible.
* Verify both boom cables are properly
tensioned and that LST3S is properly
centered in the bracket.
* Verify LSB2S (C59CNK, BL/WH, TCON
J7-5) operates properly. Signal should
normally by 12 V. If cable tension is loose,
signal should be 0 V.
26
Primary
Boom Extend
Valve
12 Circuit
shorted to
V+
TCON detected
that C7PBE
circuit is shorted
to 12 V.
Boom Extend
and Retract
functions will
not operate.
* With a voltmeter, measure Y26. Proper
resistance should be between 5 - 60 ohms.
Replace Y26 if resistance is outside of
those values.
Содержание S-65 XC CE
Страница 87: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 77 ...
Страница 89: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 79 ...
Страница 97: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 87 ...
Страница 150: ...Service and Repair Manual September 2018 140 S 60 XC S 65 XC Part No 1288652GT This page intentionally left blank ...
Страница 151: ...September 2018 Service and Repair Manual 141 Electrical Schematic TCON ...
Страница 152: ...Service and Repair Manual September 2018 142 S 60 XC S 65 XC Part No 1288652GT Electrical Schematic TCON ...
Страница 153: ...September 2018 Service and Repair Manual Part No 1288652GT S 60 XC S 65 XC 143 Electrical Schematic PCON ...
Страница 154: ...Service and Repair Manual September 2018 144 Electrical Schematic PCON ...
Страница 155: ...September 2018 Service and Repair Manual 145 Electrical Schematic Deutz 2 9L Models ...
Страница 156: ...Service and Repair Manual September 2018 146 S 60 XC S 65 XC Part No 1288652GT Electrical Schematic Deutz 2 9L Models ...
Страница 157: ...September 2018 Service and Repair Manual Part No 1288652GT S 60 XC S 65 XC 147 Electrical Schematic Deutz D2011 Models ...
Страница 158: ...Service and Repair Manual September 2018 148 Electrical Schematic Deutz D2011 Models ...
Страница 159: ...September 2018 Service and Repair Manual 149 Electrical Schematic Perkins 404F Models ...
Страница 160: ...Service and Repair Manual September 2018 150 S 60 XC S 65 XC Part No 1288652GT Electrical Schematic Perkins 404F Models ...
Страница 161: ...September 2018 Service and Repair Manual Part No 1288652GT S 60 XC S 65 XC 151 Electrical Schematic Perkins 404D Models ...
Страница 162: ...Service and Repair Manual September 2018 152 Electrical Schematic Perkins 404D Models ...
Страница 163: ...September 2018 Service and Repair Manual 153 Electrical Schematic Ford MSG425 Models ...
Страница 164: ...Service and Repair Manual September 2018 154 S 60 XC S 65 XC Part No 1288652GT Electrical Schematic Ford MSG425 Models ...
Страница 165: ...September 2018 Service and Repair Manual Part No 1288652GT S 60 XC S 65 XC 155 Electrical Schematic Generators ...
Страница 166: ...Service and Repair Manual September 2018 156 Electrical Schematic Generators ...
Страница 167: ...September 2018 Service and Repair Manual Part No 1288652GT S 60 XC S 65 XC 157 Hydraulic Schematic 4WD Models ...
Страница 169: ......