July 2019
Service and Repair Manual
Control System Fault Codes
Part No. 1286829GT
S-
40 XC • S
-
45 XC • S
-
40 TraX •
S-45 TraX
91
ID Component ID Name
Cause
Effect
Solution
45 Platform
Level Toggle
Switch
27 Active at
startup
Toggle switch input
was detected as
HIGH at start-up.
Platform Level Up or
Down functions may
not operate,
depending on which
direction the switch
fault occurred.
*Verify with a voltmeter that the
Platform Level Up/Down Toggle
Switch (TS9) is operating properly.
* C14PLU (OR, PCON J17-2) should
be 0 V with the switch OFF and 12 V
with the switch held in the UP
position.
* C15PLD (OR/BK, PCON J17-3)
should be 0 V with the switch OFF
and 12 V with the switch held in the
DOWN position.
*Cycle power to allow the machine to
re-test the fault.
46 Platform
Rotate CW
Coil
11 Shorted
to supply
voltage
PCON detected
that V17PRL circuit
is shorted to 12 V
or GND.
Platform Rotate CW
function will not
operate.
* With a voltmeter, measure Y70.
Proper resistance should be
between 5 - 60 ohms. Replace Y70 if
resistance is outside of those values.
* Verify wiring for V17PRL (GR,
PCON J12-5) and check for open or
short circuits.
47 Platform
Rotate CCW
Coil
11 Shorted
to supply
voltage
PCON detected
that V18PRR circuit
is shorted to 12 V
or GND.
Platform Rotate
CCW function will
not operate.
* With a voltmeter, measure Y71.
Proper resistance should be
between 5 - 60 ohms. Replace Y71 if
resistance is outside of those values.
* Verify wiring for V18PRR (GR/BK,
PCON J12-4) and check for open or
short circuits.
51 Drive
Joystick
11 Shorted
to supply
voltage
Circuit C160DRV is
above 4.5 V.
Drive Forward and
Reverse functions
will not operate.
* Leave joystick in neutral position
and cycle power.
* If fault persists, with a voltmeter
check that C160DRV (WH/RD,
PCON J18-10) is at 2. 5V +/- 0.2 V at
startup and does not go above 4.5 V
or below 0.5 V when fully stroked in
each direction.
* Replace joystick if voltage check
fails.
27 Active at
startup
Circuit C160DRV
voltage was not
within the startup
voltage range of
2.5 V +/- 0.2 V.
Содержание S-40 TRAX
Страница 43: ...July 2019 Service and Repair Manual Repair Procedures Part No 1286829GT S 40 XC S 45 XC S 40 TraX S 45 TraX 33 ...
Страница 72: ...Service and Repair Manual July 2019 Manifolds 62 S 40 XC S 45 XC S 40 TraX S 45 TraX Part No 1286829GT ...
Страница 74: ...Service and Repair Manual July 2019 Manifolds 64 S 40 XC S 45 XC S 40 TraX S 45 TraX Part No 1286829GT ...
Страница 79: ...July 2019 Service and Repair Manual Manifolds Part No 1286829GT S 40 XC S 45 XC S 40 TraX S 45 TraX 69 ...
Страница 144: ...Service and Repair Manual July 2019 134 Electrical Schematic TCON ...
Страница 145: ...July 2019 Service and Repair Manual Part No 1286829GT S 40 XC S 45 XC S 40 TraX S 45 TraX 135 Electrical Schematic TCON ...
Страница 146: ...Service and Repair Manual July 2019 136 S 40 XC S 45 XC S 40 TraX S 45 TraX Part No 1286829GT Electrical Schematic PCON ...
Страница 147: ...July 2019 Service and Repair Manual 137 Electrical Schematic PCON ...
Страница 148: ...Service and Repair Manual July 2019 138 Electrical Schematic Deutz 2 9 Models ...
Страница 150: ...Service and Repair Manual July 2019 140 S 40 XC S 45 XC S 40 TraX S 45 TraX Part No 1286829GT ...
Страница 152: ...Service and Repair Manual July 2019 142 Electrical Schematic Deutz 2011 Models ...
Страница 153: ...July 2019 Service and Repair Manual 143 Electrical Schematic Perkins 404F Models ...
Страница 156: ...Service and Repair Manual July 2019 146 Electrical Schematics Ford MSG425 Models ...
Страница 157: ...July 2019 Service and Repair Manual Part No 1286829GT S 40 XC S 45 XC S 40 TraX S 45 TraX 147 Hydraulic Schematic 4WD ...
Страница 159: ......