Genie GSD106 Скачать руководство пользователя страница 36

 

 

34 

 

Chapter 5

   

Shortcut Operation Table 

 

1

System Preset Operation Table 

 

 

System Preset Operation Table 

 

Preset 80 (Call 80) 

Run PTZ Tour 1   

Preset 81 (Call 81) 

Run PTZ Tour 2   

Preset 82 (Call 82) 

Run PTZ Tour 3   

Preset 83 (Call 83) 

Start VectorScan 1   

Preset 84 (Call 84) 

Start VectorScan 2   

Preset 85 (Call 85) 

Start VectorScan 3 

Preset 86 (Call 86) 

Start VectorScan 4   

Preset 87 (Call 87) 

Start VectorScan 5   

Preset 88 (Call 88) 

Start VectorScan 6 

Preset 89 (Call 89) 

Joystick Freeze and Unfreeze Video 

Preset 90/95 (Call 90/95) 

Setup the Menus and Camera 

Preset 91 (Call 91) 

Invokes the Flashback Function 

Preset 92 (Call 92) 

 

Administrator Logon   

Preset 93 (Call 93) 

 

Operator Logon   

Preset 94 (Call 94) 

Restart Dome Power Supply (Set Preset 94 as the power 
supply for shutting down the dome)   

 

Preset point setting:    Method 1: First input “PRESET”, and then input the number of the   

                                          preset point. Press “ENTER” to complete ( No. + ENTER). 

                                 

Method 2: First input the number of preset point. Then press “SHOT”.   

                                        Press “ON” to complete (Preset No. + Shot + ON). 

 

Call Preset point:     

Method 1: First input “CALL”. Then Input the number of the preset point.   

                                        Press “ENTER” to complete (Call + Preset No. + ENTER). 

                                 

Method 2: First input the number of preset point. Then press “SHOT

”. 

                                          Press “ACK” to complete (Preset No. + Shot + ACK). 

 

Clear Preset point:   

Method 1: First input “PRESET”. Then input the number of preset point.   

                                        Press “OFF” in the end ( Preset No. +OFF) 

                                 

Method 2: First input the preset No. Then press “SHOT”.   

                                          Press “OFF” to complete ( Preset No. + SHOT + OFF). 

Содержание GSD106

Страница 1: ...GSD106 10x Optical High Speed PTZ Dome Camera User Manual...

Страница 2: ...e Device Address 5 IV Installing the Camera 5 V Connecting the Power 6 VI Controller Setting 6 VII Start Testing 6 VIII Complete the Test Summary 6 Chapter 4 Operation Menu 8 I Operating Instructions...

Страница 3: ...g position and angle 3 Crosshair operating function 4 Six Tour operations with 2 minutes recording per Tour 5 Eight groups of programmable vector scans 6 Vertical auto flip with 10 automatic forward t...

Страница 4: ...o 2 Alarm Input Yellow and White No 3 Alarm Input Grey and White No 4 Alarm Input Orange and White No 5 Alarm Input Brown No 6 Alarm Input Green and White No 7 Alarm Input Brown and White No 8 Alarm I...

Страница 5: ...24V output RS 485 Bus Is for the control signal RS 485 signal output of a controller connected to the communication input terminals of the control cable of each dome Video Is for image signal output o...

Страница 6: ...F ULTRACK OFF OFF ON OFF VICON OFF OFF OFF OFF On Off Baud Rate 5 th digit 6 th digit 2400 OFF OFF 4800 OFF ON 9600 ON OFF 19200 ON ON This figure shows the setting PELCO D protocol and baud rate of 2...

Страница 7: ...he PCB in the dome IV Install Camera Note 1 Do not connect the camera and dome with FFC in an incorrect manner 2 The installation fixing holes of for different camera may differ Set address for Dome P...

Страница 8: ...ical with that of the Dome VII Start Testing When the above are complete the Dome testing can be started 1 Direction Control Test 2 Zoom Control Test The up down left and right directions of the The C...

Страница 9: ...7...

Страница 10: ...ystick Left Right for the cursor to select the numeric value to be entered 2 Press IRIS OPEN to confirm and the number selected is displayed as indicated in the pictures below 3 Move the Joystick Left...

Страница 11: ...IRIS CLOSE Error will be prompted on screen if the input is wrong The screen goes directly into the window to be operated if the input is correct II Menu Tree List 1 Main Menu Press 90 PRE to enter th...

Страница 12: ...lect numbers 0 9 Press IRIS OPEN to confirm the selection Press IRIS CLOSE to exit to the upper level menu when programming is complete Set Preset Set Preset Press IRIS OPEN or Jovstick Left Right to...

Страница 13: ...t Name Press IRIS OPEN or Joystick Left Right to enter Press IRIS OPEN to enter Name Display ON Name Display ON OFF Joystick Left Right to select IRIS CLOSE to exit 2 2 Sector Setup Sector Setup Press...

Страница 14: ...is complete Setup Tilt start point Press IRIS OPEN or Joystick Left Right to enter Use joystick to capture Tilt start point Press IRIS CLOSE to confirm and exit to upper level menu Setup Tilt end poi...

Страница 15: ...Off Joystick Left Right to select 2 5 Start Up Scr Msg ON Start Up screen message display On Off Joystick Left Right to select 2 6 OSD Style NORMAL The style of the OSD menu is Nomal Joystick Left Rig...

Страница 16: ...t default function Preset Tour PTZ Press IRIS OPEN or Joystick Left Right to enter Number 1 Function number selection Press IRIS OPEN or Joystick Left Right to enter Delay 60 Time delay setting in sec...

Страница 17: ...Auto flip ON OFF Joystick Left Right to select 3 5 Auto Focus PTZ Auto focus options PTZ OFF Z Joystick Left Right to select 3 6 Auto AE PTZ Auto AE option PTZ OFF Z Joystick Left Right to select 3 7...

Страница 18: ...stem PAL NTSC PAL NTSC switch Joystick Left Right to select 4 4 Restart the Dome Restart the Dome Are you sure to do this IRIS OPEN to confirm IRIS CLOSE to cancel Are you sure to do this IRIS OPEN to...

Страница 19: ...e 1 Baud Rate of the Dome Joystick Left Right to select Can only be set by the R W mode of the comm setting INPUT SN Joystick Left Right to select SN Serial Number N A 4 7 Camera Memory OFF ON Automat...

Страница 20: ...to enter AE Mode AUTO AE Mode AUTO Manual Shutter Iris Bright Joystick Left Right to select Slow Shutter ON Slow Shutter ON OFF Joystick Left Right to select Shutter Speed AUTO Shutter Speed AUTO Joy...

Страница 21: ...rey1 6 White Red Green Blue Cyan Yellow Magenta Black Joystick Left Right to select Semi Transparency ON Semi Transparency ON OFF Joystick Left Right to select Press IRIS CLOSE to exit 5 5 Others Othe...

Страница 22: ...OFF Joystick Left Right to select Function OSD ON Function OSD ON OFF Joystick Left Right to select Press IRIS CLOSE to exit 6 Camera Options Camera Options Press IRIS OPEN or Joystick Left Right to e...

Страница 23: ...r Press IRIS CLOSE to Exit AWC SET Auto White Correct Joystick Left Right to select Set up the lighting for the objects under surveillance with the colour temperature of a white object such as a piece...

Страница 24: ...Joystick Left Right to enter MODE AUTO ONE PUSH MANUAL Joystick Left Right to select AUTO The Camera focus is adjusted automatically while continuously monitoring the scene ONE PUSH Only if the camera...

Страница 25: ...eed can be adjusted manually from 1 50 to 1 120000 of a second A FLK Use this mode when the screen flickers because of inconsistent lighting frequencies AGC NORMAL HIGH OFF Joystick Left Right to sele...

Страница 26: ...n already programmed tour from the options Joystick Up Down to select the Run a Tour menu Press IRIS OPEN or Joystick Left Right to run the selected tour Move the Joystick in any direction to cancel t...

Страница 27: ...to enter Number 1 Vector Scan Number 1 6 Joystick Left Right to select Program a Vector Scan Vector Scan programming Press IRIS OPEN or Joystick Left Right to enter Function name Are you sure you wan...

Страница 28: ...ess IRIS OPEN to confirm or IRIS CLOSE to cancel your selection and return to previous menu Press IRIS CLOSE to EXIT Are you sure you want to do this IRIS OPEN to confirm IRIS CLOSE to cancel Reminder...

Страница 29: ...chday Mode Joystick Left Right to select Eachday Workday Weekend Mon Tue Wed Thurs Fri Sat Sun b Enable Time Setup Enable Time Setup Press IRIS OPEN or Joystick Left Right to enter Default Time 00 00...

Страница 30: ...the dome will take the actions corresponding to the user settings of this channel when an alarm situation occurs If set to OFF this channel will make no response no matter if there s an alarm situati...

Страница 31: ...ime Default 60 Press OPEN or Joystick Left Right to enter Refer to Numeric Input Steps Instructions for details Press IRIS CLOSE to EXIT 7 4 Mask Zone Mask Setting Reserved 7 5 Temperature Programming...

Страница 32: ...is enabled and no control command is received within the specified waiting time the dome will lock up the operation until a successful re login b Operational Lock of all level users is only effective...

Страница 33: ...IRIS OPEN or Joystick Left Right to enter Note This is used for management of the system date time You can program the assignment of the operating time of the dome via this option 9 1 Date Time Setup...

Страница 34: ...nal functions It s used to select certain specific preset points and the track when the Preset Vector Tour is being selected by a specific assignment C Mode Eachday Joystick Left Right to select Eachd...

Страница 35: ...an that of the Power Timer Namely assignment will be executed first no matter it is under startup or shutdown status and the Power Timer can only be entered after the execution of Assignment has been...

Страница 36: ...Call 93 Operator Logon Preset 94 Call 94 Restart Dome Power Supply Set Preset 94 as the power supply for shutting down the dome Preset point setting Method 1 First input PRESET and then input the num...

Страница 37: ...reset or been cleared Tour does not scan them b Dwell time at each preset position is 2 seconds 5 Description of the Swing Function a The Dome automatically Swings between two specified Preset positio...

Страница 38: ...scanning speed changes along with automatic regulation of change in magnification by inverse ratio Automatic Flip 10 degree forward tracking after 180 degree automatic flip when the dome reaches verti...

Страница 39: ...37 MEMO...

Страница 40: ...38 GENIE CCTV LTD CCTV House City Park Watchmead Welwyn Garden City Hertfordshire AL7 ILT Tel 44 0 1707 330541 Fax 44 0 1707 330543 www geniecctv com Edition GN January 2014...