April 2017
Service and Repair Manual
Scissor Components
Part No. 1272217
GS-30 • GS-32 • GS-46 • GS-47
145
20 When prompted, press and hold the Function
Enable and Platform Down buttons. The
platform will lower, then automatically stop at a
predetermined point to gather data. Allow the
ground controls to gather data.
21 Continue pressing the Function Enable and
Platform Down buttons throughout the
lowering and data gathering sequence. The
machine will stop to gather data and lower
several times before the machine reaches the
stowed position. When the platform reaches
the stowed position, press the enter button.
Note: Software revision H or prior, and
GS-3032, GS-2646 and GS-4047 models,
continue to step 24.
Note: All other models with software revision J
or higher, continue with step 22.
22 When prompted, press and hold the Function
Enable and Platform Up buttons until the
platform reaches full height. When the
platform reaches full height, press the enter
button.
Note: If the Function Enable or Platform Up buttons
are released while the machine is collecting data,
the GCON LCD will prompt the user to lower the
platform for 5 seconds before prompting to raise
the platform to full height again.
23 When prompted, press and hold the Function
Enable and Platform Down buttons until the
platform is fully stowed. When the platform
reaches the stowed position, press the enter
button.
Note: If the Function Enable or Platform Down
buttons are released while the machine is
collecting data, the GCON LCD will prompt the
user to raise the platform for 5 seconds before
prompting to lower the platform to the stowed
position again.
Note: If the machine is switched to PCON mode to
drive the machine to an area for weight removal,
step 3 and steps 5 through 14 will have to be
repeated before Full Load Calibration: Part 2 is
performed. Additionally, the CO25 fault will appear.
This is expected and the data collected in Full Load
Calibration: Part 1 has not been lost.
24 Using a suitable lifting device, remove the test
weight from the platform deck.
25 After the weight is removed from the platform
deck, press the Enter button to confirm the
weight has been removed.
Содержание gS-1530/32
Страница 170: ...Service and Repair Manual April 2017 154 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 218: ...Service and Repair Manual April 2017 202 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 245: ...April 2017 Service and Repair Manual 229 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 248: ...Service and Repair Manual April 2017 232 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 299: ...April 2017 Service and Repair Manual 283 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 302: ...Service and Repair Manual April 2017 286 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 339: ...April 2017 Service and Repair Manual 323 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 341: ...April 2017 Service and Repair Manual 325 Electrical Schematic Foot Switch option All Models ...