![Genie GDG360BT Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/genie/gdg360bt/gdg360bt_user-manual_2212239004.webp)
User Manual
Access Control Proximity Reader with Bluetooth
4
2. Operation Notes
3. Diagram / Dimensions
The GDG360BT includes one pair of NO/NC/COM output contacts, which can
directly connect to a locking device or connect in parallel or series with access
control systems.
Reed Switch
Door closed status: NO contact
Door open status: NC contact
Using Reset Jumper
Note:
1. Make sure that the power input and SSR rating output (2A/12VDC) are correct.
2. Make sure that the “+” and “-” wires are connected correctly.
3. The door strike or relay must have a varistor or a diode across the door strike
terminals to suppress the back EMF of the strike. Failure to do so will damage
the relay contacts and electronic components, or even burn the controller.
86mm
86mm
20mm
Plug x2
Pan Head Phillips Screw x2
LED Indicator