Quick Start Guide

Contactless Request To Exit Button

4

6. Functions

7. DIP Switch Setting

•  As you put your hand near the exit button the capacitive technology will 

trigger the device without the need to actually touch it. The colour of the exit 

button will change from blue to green in colour when triggered. At the same 

time, the relay inside the exit button device will trigger for 1 second and the 

built-in buzzer will beep once.

•  To adjust the door open duration, please power off the exit button. Change 

the DIP Switch setting to alter the door open duration from the table below, 

adjustable from 1 to 15 seconds, re-apply power again for the change to take 

place.

•  Support mechanical override.

•  Support an external device/switch to trigger the unit.

•  Remote Control is an option (Special order item)

1

ON

1

No. 1,2,3,4 are used for adjusting door open duration.

ON = Valid

OFF = Invalid

Door open duration = To add all the ON position 

switch numbers

Example:

If we set 1 and 4 to “ON”, the door open during will be:

1+8=9 the decimal number is 9 seconds (decimal 

number)

*Setting all DIP switch to OFF position means door 

duration = 1 sec.

OFF

0

2

ON

2

OFF

0

3

ON

4

OFF

0

4 ON

8

OFF

0

5 ON

Turn off (buzzer)

Turn off the buzzer

OFF

Turn on (buzzer)

Turn on the buzzer (default)

6 ON

N/A

N/A

OFF

N/A

7

ON

N/A

N/A

OFF

N/A

8 ON

Trigger distance 

(near)

2~3cm

OFF

Trigger distance 

(far)

5cm (default)

NOTE:
Change the DIP Switch, please power off for changes to take place.

Содержание CAP-REX-1G

Страница 1: ...Quick Start Guide Please read these instructions carefully before operating the unit and keep for further reference Contactless Request To Exit Button CAP REX 1G ...

Страница 2: ...ic failure Built in a digital timer to control the relay output timing from 1 to 15 sec Back lit design and built in buzzer buzzer selectable Capacitance proximity technology has been used instead of infrared technology environmental independent design 2 Specifications Request To Exit Indication Colour changes from Blue to Green with a beep Request To Exit Output Dry contact output REX Relay NC NO...

Страница 3: ... 4 PCB Setting Diagram 5 Wiring For door open duration setting from 1 to 15 sec Label Description VDD Power input 12V 24VDC RTE_COM Exit button output dry contact RTE_NO RTE_NC MO External device to trigger the door open active low GND Signal ground 0 VDC ...

Страница 4: ... apply power again for the change to take place Support mechanical override Support an external device switch to trigger the unit Remote Control is an option Special order item 1 ON 1 No 1 2 3 4 are used for adjusting door open duration ON Valid OFF Invalid Door open duration To add all the ON position switch numbers Example If we set 1 and 4 to ON the door open during will be 1 8 9 the decimal nu...

Страница 5: ...umpers to the required positions 3 Secure the exit button to the back box with correct screws as shown below 4 There are 2 M type buckles at the bottom of the cover as shown in the below left image Align them into the slot at the bottom of the module and then push the upper part of the cover up as shown below in right image to secure exit button cover Unit is now ready to use M Type buckles ...

Страница 6: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk ...

Отзывы: