![Genie CCTV SDDVR Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/genie-cctv/sddvr/sddvr_installation-and-user-manual_2212563018.webp)
18
5. EVENT SETUP
5.1 ALARM SETUP
5.1.1 ALARM INPUT (ON / OFF): Select ‘ON’ if you want to use alarm input device.
5.1.2 INPUT TYPE: Select alarm input type between ‘Normally Open’ and ‘Normally Closed’
NC: NORMAL CLOSE
NO: NORMAL OPEN
5.1.3 ALARM OUTPUT:
ALARM INPUT
ALARM OUTPUT
Normally Open
Normally Open
Alarm input type is Normal Open.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normally Open
Normally Closed
Alarm input type is Normal Open.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Normally Closed
Normally Open
Alarm input type is Normal Close.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normally Closed
Normally Closed
Alarm input type is Normal Close.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Note:
In NORMAL-CLOSE mode, if an intruder cuts the cable line that connects the sensor to the SDDVR,
sensor recording starts automatically. In NORMAL-OPEN mode, if an intruder cuts the cable line that connects
the sensor to the SDDVR, the sensor recording will not start at.
5.2 MOTION DETECTION
5.2.1 SENSITIVIITY (LOW / NORMAL / HIGH): You can select the degree of sensitivity of motion detection.
Set to HIGH for greater sensitivity to small movements.
ON
N.O.
ON
1. OFF
Low
ON
2. OFF
3. OFF
4. OFF
TIME