7.7 More information

For the latest information on products and services, please visit our website:

http://www.genfine.com/

.

We strive to provide you with suitable and helpful documents. If you have

any comments on this user manual, please tell your local agent. We will be very grateful.

7.8 Safety and User Guide

(1) To reduce the risk of injury or biohazard contamination, and to avoid fire or electric shock,

always follow basic safety precautions when using Purifier HTS.

(2) Before operating the instrument, please read this instruction manual completely. Failure to

read, understand or follow this manual may cause damage to the instrument and laboratory, injury to

the operator, or poor performance of the instrument.

(3) Comply with all "Warning", "Caution" statements, safety symbols and markings on the

instrument and documentation.

(4) This equipment can only be operated with specially designed software.

(5) Do not force the microplate onto the turntable.

(6) Purifier HTS is for laboratory research use only. Please comply with appropriate laboratory

safety precautions, such as wearing protective clothing and following certified laboratory safety

procedures.

(7) Strictly follow the preventive maintenance instructions to keep the instrument in its best

condition and ensure maximum reliability. Poorly maintained instruments may cause abnormal test

results.

Warning

This product contains strong permanent magnets. People who wear

pacemakers or metal prostheses should not use this product. If the

pacemaker or prosthesis comes into close contact with a strong magnetic

field, it may be affected or damaged.

Содержание P96S-B01-01

Страница 1: ...GENFINE Purifier HTS User manual V1 0 GENFINE BIOTECH CHANGZHOU CO LTD...

Страница 2: ...Maintenance 13 5 1 Instrument Maintenance 13 5 2 Cleaning 13 5 3 Magnetic Rods Cleaning 13 5 4 Waste disposal 13 5 5 Decontamination Procedure 13 5 6 Packaging for repair 14 5 7 Service Contract 14 5...

Страница 3: ...Chapter 8 Manufacturer and Medical Device Information 21 Chapter 9 Order Information 22 Appendix A Certificate of Decontamination 23 Appendix B System Log 24...

Страница 4: ...And by this it can complete the entire nucleic acid extraction process The instrument can be applied for the extraction and purification of nucleic acid from different clinic samples Purifier HTS is e...

Страница 5: ...Chapter 2 Function Introduction 2 1 Main Components 2 1 1 Front View Figure 2 1 Purifier HTS Front view 2 1 2 Rear View Figure 2 2 Purifier HTS Rear View 2 1 3 Inside View Figure 2 3 Purifier HTS Insi...

Страница 6: ...TS automatic nucleic acid extractor adopts magnetic beads separation technology Figure 2 4 In this method a disposable magnetic rod tip comb is loaded on the magnetic rod and then the magnetic beads a...

Страница 7: ...Page 4...

Страница 8: ...s are broken please contact the manufacturer in time 3 2 Environment Requirement When installing Purifier HTS avoid placing it in the places where there is a lot of dust vibration strong magnetic fiel...

Страница 9: ...ibes the installation Setting that must be performed prior to operating or relocating the instrument 3 4 1 Power Connection Warning Make sure that the power switch on the rear panel is in the O positi...

Страница 10: ...r HTS software and cannot be edited or deleted The user program is the program that the user edits and saves themselves and the user can edit and delete the user program according to the experiment ne...

Страница 11: ...details interface The program detail interface displays the step number board position number item name time volume temperature and other parameters After confirming that the program is correct click...

Страница 12: ...n Click New Program on the main interface to create a new programs according to the customer s requirements Enter the program name and select the program type Click or Back to return to the main scree...

Страница 13: ...setting interface The heating temperature and time are selected according to the requirements of the experiment The temperature setting range is 0 99 C and the temperature can be switched The entry po...

Страница 14: ...ition Click confirm to run the program click Cancel to return to the program details and click pre heating switch to turn on and off the pre heating function 4 2 4 User Settings The user can select Us...

Страница 15: ...ter mild detergent SDS sodium lauryl sulfate or soap solution 3 If contaminated reagents have been spilled on the workbench please clean them with 75 ethanol or other disinfectants see page 12 Deconta...

Страница 16: ...t dust and dirt from entering the instrument At least once a week clean the surface of the turntable with a soft cloth or paper towel dampened with ethanol mild detergent SDS sodium lauryl sulfate or...

Страница 17: ...tion Before removing the instrument from the laboratory or performing any repair on it it must be thoroughly cleaned When sending the instrument for repair please remember Inform the reason for repair...

Страница 18: ...ment is carried out in accordance with the laws and regulations of the local authorities on the recycle of electronic equipment and waste Disposal procedures vary from country to country For the origi...

Страница 19: ...maximum relative humidity is 80 when the temperature is lower than 31 and the humidity drops lineary to 50 at 40 Transport condition 40 C to 70 C packed by transport package Storage condition 25 C to...

Страница 20: ...y of heating module from 10 C to 105 C 2 Display 10 LCD 1024 600 pixel color display 6 3 Safety parameters 6 4 Compliance Purifier HTS meets the following compliance YY 0505 2005 IEC 60601 1 2 2001 GB...

Страница 21: ...error If the error is reported repeatedly after restarting contact the engineer M01 M axis photoelectric switch error If the error is reported repeatedly after restarting contact the engineer M02 M ax...

Страница 22: ...ick Operation Guide 1 pcs 8 Warranty Card 1 pcs 9 Certificate of quality 1 pcs 10 Quality inspection report 1 pcs 11 96 well plates 1 pcs 12 96 magnetic rod tip comb 1 pcs 7 4 Interpretation of Graphi...

Страница 23: ...e of the instrument 3 Comply with all Warning Caution statements safety symbols and markings on the instrument and documentation 4 This equipment can only be operated with specially designed software...

Страница 24: ...rmation Manufacturer GENFINE BIOTECH CHANGZHOU CO LTD Medical device production record number NMPA Reg No 20220032 Manufacturer Address Building E4 Changyang Road West Taihu Technology Industrial Park...

Страница 25: ...HTS configuration Table 9 1 Product Item List Item No Device System P96S B01 01 Purifier HTS Chinese version P96S B01 02 Purifier HTS English version P96S B01 03 Purifier HTS Custom version 9 2 List o...

Страница 26: ...tamination specific information _________________________________________________ Decontamination procedure1 ____________________________________________________ Date and place _______________________...

Страница 27: ...Page 24 Appendix B System Log Device name and number User Date Remarks...

Страница 28: ...Page 25 GENFINE BIOTECH CHANGZHOU CO LTD www genfine com marketing genfine com...