Bosch
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
32
EN.100.007-V4.8.C3.(1)
To record on contact, click the
Contact
tab.
NOTE
If recording on
Contact
is selected, the recording settings configured on the Divar
will override the Omnicast settings.
iii
Select a
Contact recording
mode (
Follows
,
F post
, or
Fixed duration
).
iv
Select the
Duration
,
Resolution
,
Quality
, and
Frame rate
for the recording stream.
To record on motion, click the
Motion
tab.
NOTE
If recording on
Motion
is selected, the recording settings configured on the Divar
will override the Omnicast settings.
v
Set the Motion recording mode to
Fixed duration
.
vi
Select the
Duration
,
Resolution
,
Quality
, and
Frame rate
for the recording stream.
6
for each recording profile you want to create, and for each unit using
that profile.
7
To set when each recording profile is active, click
Configuration > Schedule > Schedule
from the Divar’s home page.
8
Select a profile, and set the date and time that profile should record.
NOTE
These schedules are independent of Omnicast schedules.
9
Click
Save > Close
.
Configuring Bosch VRM units
Best practice:
For optimal performance, it is best practice to set the playback mode for Bosch
VRM (Video Recording Manager) units to use
iSCSI connection
, which is a storage unit for net-
work drives.
To use the
iSCSI connection
playback mode, make sure that all Archiver servers and cameras
recording on the iSCSI have full read access to all iSCSI storage units managed by the Bosch
VRM. For more information, please refer to the storage vendor’s documentation.