Thank you for choosing equipment from Genesis Rescue Systems. We strive to
give our customers the latest technology available in rescue products; from
the newest lightweight alloys, to the most innovative designs in the industry. We
continually update and refine our products in order to offer the highest quality
equipment at a reasonable price. The Mach III Power Unit is third party tested,
ISO 9001 Quality Assurance Certified and NFPA 1936 Compliant. At Genesis Res-
cue Systems we feel we offer the highest quality rescue equipment available;
so do our customers! Thank you again for choosing Genesis Rescue Systems.
Read the entire instructions and disclaimer information. Failure to follow all in-
structions could cause permanent damage to the battery and its surroundings
and could cause bodily harm.
The Genesis Rescue Systems E-Pack requires the user to follow routine guide-
lines in order to prolong the life of the battery.
Do not leave the battery unused for extended periods of time. If the battery
pack is approaching 6 months with no use check the battery level on the
E-Pack, and charge if necessary.
The typical battery life of the cells contained in the E-Pack is about 4-5 years
or 1000 charging cycles, whichever occurs first. From fully charged to fully
discharged counts as one cycle. When the battery approached the end of its
life the cells will struggle to hold charge and the performance of the E-Pack will
decrease. In the event, contact your local Genesis Rescue Systems distributor
for service options.
E-PACK BATTERY MAINTENANCE AND CARE
• Routinely check the battery level of the E-Pack
• DO NOT store the E-Pack connected to the charger.
• If the E-Pack has been in use for an extended period of time allow the unit
to stabilize for 15-20 minutes before attaching the charger.
• After charging the E-Pack allow the unit to stabilize for 30 minutes before
use.
• Stop using or charging if the unit leaks or swells or its temperature is above
160ºF (71ºC). Or anything else abnormal occurs.
• Always use approved Genesis Rescue Systems E-Pack charger. Never
charge unattended. Charge in a fire safe location.
• Do not discharge battery with a device that draws other than 28v. This can
cause battery damage, burst,or could cause fire or explosion.
E-PACK MAINTENANCE AND GUIDELINES