Thank you for choosing equipment from Genesis Rescue Systems. We strive to 

give our customers the latest technology available in rescue products; from 

the newest lightweight alloys, to the most innovative designs in the industry. We 

continually update and refine our products in order to offer the highest quality 

equipment at a reasonable price. The Mach III Power Unit is third party tested, 

ISO 9001 Quality Assurance Certified and NFPA 1936 Compliant. At Genesis Res-

cue Systems we feel we offer the highest quality rescue equipment available; 

so do our customers! Thank you again for choosing Genesis Rescue Systems.

Read the entire instructions and disclaimer information. Failure to follow all in-

structions could cause permanent damage to the battery and its surroundings

and could cause bodily harm.

The Genesis Rescue Systems E-Pack requires the user to follow routine guide-

lines in order to prolong the life of the battery.

Do not leave the battery unused for extended periods of time.  If the battery 

pack is approaching 6 months with no use check the battery level on the 

E-Pack, and charge if necessary.

The typical battery life of the cells contained in the E-Pack is about 4-5 years 

or 1000 charging cycles, whichever occurs first.  From fully charged to fully 

discharged counts as one cycle. When the battery approached the end of its 

life the cells will struggle to hold charge and the performance of the E-Pack will 

decrease. In the event, contact your local Genesis Rescue Systems distributor 

for service options.

E-PACK BATTERY MAINTENANCE AND CARE

•  Routinely check the battery level of the E-Pack

•  DO NOT store the E-Pack connected to the charger.

•  If the E-Pack has been in use for an extended period of time allow the unit 

to stabilize for 15-20 minutes before attaching the charger.

•  After charging the E-Pack allow the unit to stabilize for 30 minutes before 

use.

•  Stop using or charging if the unit leaks or swells or its temperature is above 

160ºF (71ºC). Or anything else abnormal occurs.

•  Always use approved Genesis Rescue Systems E-Pack charger. Never 

charge unattended. Charge in a fire safe location.

•  Do not discharge battery with a device that draws other than 28v. This can  

cause battery damage, burst,or could cause fire or explosion.

E-PACK MAINTENANCE AND GUIDELINES