Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data
without the UPC-A check digit, simply scan the
Do Not Transmit UPC-A Check Digit
bar code under
. The decoder issues a fast warble beep and the LED turns green, signifying
a successful parameter entry.
Other parameters, such as
Set Length(s) for D 2 of 5
require scanning several bar codes. See the individual
parameter, such as
Set Length(s) for D 2 of 5
, for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults
lists the defaults for all symbologies parameters. To change the default values, scan the appropriate
bar codes in this guide. These new values replace the standard default values in memory. To recall the default
parameter values, scan the
.
Table 3-1
Parameter Defaults
Parameter
Parameter
Number
Default
Page
Number
Disable All Code Types
UPC/EAN
UPC-A
01h
Enable
UPC-E
02h
Enable
UPC-E1
0Ch
Disable
EAN-8/JAN 8
04h
Enable
EAN-13/JAN 13
03h
Enable
Bookland EAN
53h
Enable
Bookland ISBN Format
F1h 40h
ISBN-10
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
10h
Ignore
User-Programmable Supplementals
Supplemental 1:
Supplemental 2:
F1h 43h
F1h 44h
N/A
UPC/EAN/JAN Supplemental Redundancy
50h
10
G S -R 5000 -51C Barcode Configuration Document