Wiring

Testing the System

 

1. Re-assemble system and check all connections.

2. Restore power to the HVAC system.

3. Start HVAC System by raising thermostat setting.

4. Check to see that GFX4 display is on.

5. Set to TEST MODE by pressing “Drop” and 

“thermo” together for 5 seconds.  The relay will 

close and the “+” will flash for 2 minutes or press

a  key to set to OFF MODE.

6. Set to OFF mode to verify humidifier operation 

ceases.

7. The GFX4 will stay in OFF Mode unless set to 

Manual or Automatic mode.  See “Operation”.

PUSH

5 SEC.

BLINK !

Operating Modes

Press any button to light the display.  Press the “DROP” 

button to select the Operating Mode, Off, Manual or Auto.

OFF Mode

The Humidifier is turned off.  

MANUAL Mode

 

The GFX4 will work to maintain the single

humidity selected.  You can set your desired 

humidity level by pressing “UP” or “DOWN”. 

The humidifier will turn ON or OFF according 

to your manual setting.  The humidifier will 

operate when the measured relative 

humidity falls more than 1% below the set point until 

the measured relative humidity is 1% above the set 

point.  When the humidifier is operating, the “+” will 

display.  Humidity may have to be lowered when 

weather is colder or if condensation is suspected.  The 

settings table to the right or a similar table may be used 

to compensate for cold outside temperatures.

    Outdoor        Suggested 

Temperature       Setting

15% 

20%

25%

30%

35%

40%

-29°C

-23°C

-18°C

-12°C

- 7°C

- 1°C

-20°F

-10°F

0°F

+10°F

+20°F

+30°F

Display a Temperature

Press the “THERMOMETER” button to move between displaying indoor and 

outdoor temperature.  “Tree” will be displayed when showing outdoor 

temperature.  “House” will be displayed when showing indoor temperature.  To 

change between °F and °C units, press the “ °F/°C ” button.

Limited Warranty

This humidistat is warranted to the consumer against defects in materials and workmanship 

for a period of one year from the date of installation.  Defective parts will be repaired 

without charge except for removal, reinstallation and transportation costs.  To obtain repair 

service under this limited warranty, the consumer must send the defective part to the 

manufacturer.  
There are no express warranties covering this humidistat other than set forth above.  The 

implied warranties of merchantability and fitness for a particular purpose are limited in 

duration to one year.  The manufacturer assumes no liability in connection with the 

installation or use of this product, except as stated in this limited warranty.  The manufac-

turer will in no event be liable for incidental or consequential damages.
Any questions pertaining to this limited warranty should be addressed to the manufacturer.  

USA: The manufacturer has elected not to make available the informal dispute settlement 

mechanism which is specified in the Magnuson-Moss Warranty Act.

 

Technical Support

Canadian General Filters, Ltd.

 

400 Midwest Road Toronto, 

ON M1P3A9 Canada 

www.

GeneralAireIAQ.ca

Tel 416-757-3691

FORM GFX4-11 Rev. A           9805-100-001

Trouble Shooting

“HOUSE” Flashing

     The indoor temperature sensor has failed.

“TREE” Flashing

         The outdoor temperature sensor has failed.

Humidifier Turns On and Off Repeatedly

  

     Check that input voltage is between 18 and 30 volts, AC and not intermittent.

     Check that humidistat is NOT mounted:  1.  on supply duct.  2. downstream of

     humidifier.  3. closer to humidifier than 12 inches.

     Make sure that Outdoor Sensor wiring is not close to line voltage wires.

Humidifier Runs Continuously

     If humidifier operates while HVAC system is off, check that power to humidifier 

     is switched with HVAC operation.

     If humidifier operates every time HVAC System runs, compare humidity to set 

     point.  If humidity is lower than set point, humidistat will call for operation.

Humidifier Does Not Run

     Check wiring to/from GFX4 control.  Verify 18-30 volts.  Use “TEST MODE” .

Humidifier Runs When Air Conditioning Is On

     If this is undesirable, change wiring to be powered only in heating periods.

Humidity not high enough

     Fault with Humidifier.  Check humidifier, water supply, electrical connections.

     HVAC operating time too short.  Check humidifier trouble shooting.

     Humidifier undersized.  Review humidity load and humidifier capacity.

Humidity Too High

     Wiring fault.  Set GFX4 to “OFF” mode and check that operation ceases.

     Outdoor sensor is being kept warm.  Check that sensor is not buried in snow,

     on south side of house being warmed by sun or is too far inside of air intake.

AUTO Mode

The GFX4 will automatically raise the humidity as the outdoor temperature increases.  

This provides the highest possible humidity.  The GFX4 will automatically lower the 

humidity as temperatures drop.  This minimizes the risk of condensation on cold 

surfaces like windows.  
The Auto Humidity Index Set Point may be changed from 0 (low) to 10 (high) by 

pressing “UP” or “DOWN”.  The Humidity Index is based on the outdoor temperature 

and indoor humidity. The humidifier will switch ON/OFF according to the calculated 

auto humidity index set point.  When the humidifier is operating, the “+” will display.  

Lower Index settings are for older homes with less insulation and poor vapor barriers.  

Higher Index settings are for newer homes with complete vapor barriers, triple pane 

windows and high R value insulation.  

     1-2 

Older than 1950, no vapor barrier, little insulation.

     3-4 

Built 1950-1965, no vapor barrier, R6 insulation.

     5-6 

Built 1965-1975, craft vapor barrier, R11 insulation.

     7-8 

Built 1980-1990, craft vapor barrier, R19, double pane windows.

9-10 

Built after 1990, poly vapor barrier, R38 insulation, foam exterior cladding,

triple pane windows.

If condensation is seen or suspected, reduce index by 2 until condensation stops.  The 

level bars indicate the humidity index; one bar for two index points.   

“DROP”

“UP”

“DOWN”

OFFSET Mode

To change the calibration of the GFX4, an offset may be entered to the Humidity, 

Indoor Temperature or Outdoor Temperature displays.  Press both “UP” and 

“DOWN” buttons together to enter OFFSET mode.  The word “OFFSET” and “RH” 

will display. Press “UP”  or “DOWN” to change the humidistat’s Humidity 

calibration.  Press both “UP” and “DOWN” buttons together again to change the 

Indoor Temperature offset.  Press both “UP” and “DOWN” buttons together again 

to change the Outdoor Temperature offset.

Humidity

Outdoor Temperature °F

Index

-20

-10

0

10

20

30

40

50

1

0

5

10

15

20

25

30

35

2

3

8

13

18

23

28

33

38

3

6

11

16

21

26

31

36

41

4

9

14

19

24

29

34

39

44

5

12

17

22

27

32

37

42

47

6

15

20

25

30

35

40

45

50

7

18

23

28

33

38

43

48

53

8

21

26

31

36

41

46

51

56

9

24

29

34

39

44

49

54

59

10

27

32

37

42

47

52

57

62

AUTO Mode Target Humidity

WIRING OUTDOOR SENSOR 

SPLICES: NO 

MORE 

THAN ONE 

PER LEAD

200 FEET MAX.

NOTE:  Separate sensor leads from

line voltage wires by at least 4 inches. 

FIELD

SUPPLIED

SNSR 2

SNSR 1

FAN 2 (GF)

FAN 1 (GT)

HUM 2

HUM 1

AC C

AC L

 (R)

SNSR 2

SNSR 1

FAN 2 (GF)

FAN 1 (GT)

HUM 2

HUM 1

AC C

AC L

 (R)

SNSR 2

SNSR 1

FAN 2 (GF)

FAN 1 (GT)

HUM 2

HUM 1

AC C

AC L

 (R)

SNSR 2

SNSR 1

FAN 2 (GF)

FAN 1 (GT)

HUM 2

HUM 1

AC C

AC L

 (R)

WIRING TO FAN POWER HUMIDIFIER

CONSTANT

24 VOLTS

YELLOW
YELLOW

120 VOLTS

SWITCHED 

W/ FURNACE 

OPERATION

TO FURNACE 

BLOWER

WIRING TO 24V. HUMIDIFIER

CONSTANT

24 VOLTS

24 VOLTS

SWITCHED 

W/ FURNACE 

OPERATION

24 VOLT HUMIDIFIER

SOLENOID VALVE OR

DRUM MOTOR

 

WIRING TO STEAM HUMIDIFIER

 

N2

GND

N1

AB

AB

GND

IN
NO

C

NC
C

NO
GND

24V

EXT FAN     

ALARM

JUMPER

JUMPER

JUMPER

JUMPER