Installation Manual
Model GF-4200PFT
Evaporative Humidifiers
®
Please Read And Save These Instructions
Canadian General Filters, Ltd.
400 Midwest Road
Toronto, ON M1P3A9
Toll Free: (888) 216-9184
www.generalaireiaq.ca
IMPORTANT:
To ensure your safety and the
longevity of your unit, we recommend:
•
Contacting a licensed contractor to perform
maintenance or repairs.
•
Changing your Vapor Pad
®
at the start of each
heating season.
!
Inside The Box
• GF-GA900 Vapor Pad
®
• Pulse Solenoid
• Integral Bypass Damper With Duct Collar
• Manual Humidistat
• 24V Transformer
• Hardware Kits
• 1/4" Diameter plastic supply tubing for hot or cold water applications
• 6" Diameter rigid and flexible by-pass duct
• Electrical wire
• 1/2 x 1/2 x 1/4 CSA approved ball valve
•
HSA055 Pulse
Electronic Controller
• Drain Hose
•
WARNING
:
DISCONNECT ELECTRICAL POWER
BEFORE BEGINNING INSTALLATION.
WARNING
:
Do not install where ambient temperatures fall below 32°F / 0° C or where plenum temperatures exceed 200° F / 93° C.
For maximum evaporative capacity, install this humidifier on the warm air supply plenum.
!
!
WARNING!
This symbol and the word "WARNING" indicates:
IMPORTANT INSTRUCTIONS!
Failure to heed
CAUTION!
or
WARNING!
can result in serious injury or death.
CAUTION
!
This symbol and the word "CAUTION" indicates:
IMPORTANT INSTRUCTIONS!
!
!
!
!
Canadian General Filters
Limited
Plenum Installation Location:
Model GF-4200PFT
humidifiers may be installed on either the return or supply
plenum of a forced air handling system. The humidifier's bypass
panel is reversible and can be mounted on the right or left side
of the humidifier. Select a location for the humidifier that allows
for service and maintenance.
Vertical
Installation
Options
Return
Return
Supply
Supply
Horizontal Installation
Drain Line
Drain Line
GF-4200PFT
1. Your new humidifier carries a 5-year limited warranty.
2. For our complete warranty policy visit www.generalaireiaq.ca.