The condition indicator gauge will show when media replacement is required.  Use Air Cleaner media assembly Part No. 12758.

CARE AND MAINTENANCE

Slide  the  assembled  media  frame  into  the  air  cleaner 

cabinet.  Be sure the airflow arrow on the media frame 

points  toward  the  furnace  blower.    The  plastic  pleat 

spacers  are  always  on  the  downstream  side  of  the 

filter media.  Attach outer cover.

Turn on electricity and run furnace blower on highest 

speed.    Calibrate  condition  indicator,  with  a  small 

screwdriver  adjust  the  calibration  screw  to  put  the 

pointer in the center of the “FILTER IS CLEAN” range.

Install the plastic pleat spacers, being careful to insert 

one  support  finger  between  each  pleat.    Press  each 

end  of  the  pleat  spacers  down  firmly  to  fully  engage 

the  media  frame.    Pleat  spacers  may  snag  on  air 

cleaner  cabinet  if  not  pressed  down  below  media 

frame rail.   

Place new media pack (Part No. 12758) onto the media 

frame.  Slide media pack toward foam gasket.  Line up 

holes  in  the  cardboard  strips  with  the  holes  in  the 

media frame. 

Turn off electricity to furnace.  Pull front cover off and 

slide media carrier out of air cleaner cabinet.  Place air 

cleaner media frame on table with plastic pleat spacers 

on top.  Loosen pleat spacers by gently lifting at each 

end.  Carefully remove all pleat spacers.  Lift used air 

cleaner  media  out  of  frame  for  disposal  and  clean 

media frame. 

AIR

FILTER

BLOWER

RETURN

AIR

GAGE

1

2

3

4

5

FILTER

CONDITION

FILTER IS CLEAN

C

H

A

N

G

FI

LT

ER