This air cleaner is designed for use in systems up to 2000 CFM.  For higher airflows additional units 

may be required.  See Typical Installations below.

FOR INSTALLATION IN THE

RETURN AIR DUCT OF ANY

FORCED AIR HEATING AND

COOLING SYSTEM

INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION

             IS COMPLETE.   LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER

MODEL AC-22

HIGH EFFICIENCY

AIR CLEANER

INSTALLATION INSTRUCTIONS

HIGH BOY

COUNTER-FLOW

RETURN AIR

RETURN AIR

WARM AIR

WARM AIR

WARM AIR

G

ENERALAire

  AC-22

HIGH EFFICIENCY AIR CLEANER

IMPORTANT:  A 26 INCH CLEARANCE MUST BE ALLOWED FOR REMOVAL OF THE MEDIA FRAME 

ASSEMBLY FROM THE CABINET.
1.  Turn off electricity to furnace.
2.  Pull front cover off and slide media carrier out of air cleaner cabinet.  Discard packing material.
3.  Remove and discard existing furnace air filter.
4.  Install cabinet in return air system.  Duct supports are recommended to support weight of cabinet.
5.  Refer to care and maintenance instructions for installation of air cleaner media and pleat spacers.
6.  Slide the media frame assembly into the cabinet.  Be sure the airflow arrow on the media frame points toward

     the furnace blower.  The plastic pleat spacers are always on the downstream side of the filter media.
7.  Install condition indicator and nameplate in upright orientation.  
8.  Turn on electricity and furnace, calibrate condition indicator and check performance of all equipment.

LOW BOY

RETURN AIR

WARM AIR

G

ENERALAire

FLOW THRU

SERIES HUMIDIFIER

Fresh Indoor Air Quality