background image

RETURN FOR REPAIR POLICY 

Every effort has been made to provide you with a reliable product of superior quality.
However, in the event your instrument requires repair, please contact our Customer
Service to obtain an RGA (Return Goods Authorization) number before forwarding the
unit via prepaid freight to the attention of our Service Center at this address:

General Tools & Instruments
80 White Street
New York, NY 10013
212-431-6100

Remember to include a copy of your proof of purchase, your return address, and your
phone number and/or e-mail address.

14

Содержание DAF4207SD

Страница 1: ...DAF4207SD USER S MANUAL ANEMOMETER THERMOMETER WITH DATALOGGING SD CARD Please read this manual carefully and thoroughly before using this product...

Страница 2: ...se 4 5 Setup 6 8 Normal Operation 8 9 Holding and Storing Measurements 9 Automatic vs Manual Datalogging 10 Transferring Data from the SD Card to a Computer 11 Specifications 12 Maintenance Troublesho...

Страница 3: ...tomatic temperature compensation for measurements made by the combination probe or Type K or J thermocouples the ability to hold readings and display maximum and minimum readings and an automatic powe...

Страница 4: ...f function Powered by six AA batteries or optional 9V AC DC adapter OPERATING INSTRUCTIONS WHAT S IN THE CASE The DAF4207SD comes fully assembled in a carrying case along with a combination air speed...

Страница 5: ...n 1 7 Socket for combination air speed temperature probe 1 8 Socket for optional Type K or J thermocouple 1 9 SD card socket 1 10 RS 232 output jack 1 11 RESET button 1 12 Socket for 9VDC AC adapter 1...

Страница 6: ...y appear Once the display has stabilized perform the following eight setup steps in the order presented 3 Set the date and time Press the SET button callout 1 5 and hold it for at least five seconds u...

Страница 7: ...d the lower part of the display will show the term tYPE Press the SET or LOGGER button until your thermocouple s type K or J appears on the display Then press the REC ENTER button to store the selecti...

Страница 8: ...NEXT button Pressing the button repeatedly toggles between the two modes When the FUNC HOLD NEXT button is released the selected mode becomes the default until the button is pressed again By default...

Страница 9: ...pressing the SET button which has the words Time check stenciled below it Doing so causes both values to appear briefly at the lower left of the display HOLDING AND STORING MEASUREMENTS 5 To hold a me...

Страница 10: ...procedure detailed earlier Then press the REC ENTER button once The display will show the term REC on the top line a value in the middle and below it the letter P on the left and a number from 1 to 9...

Страница 11: ...ither directly if it has an SD card slot or through an SD card reader Because the files containing time stamped data logs have the file extension xls they open in Microsoft s Excel application Figures...

Страница 12: ...ptions 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 0 seconds to 1 hour Settable parameters Date time auto power off beep sound sampling time decimal point or comma decimal division temperature u...

Страница 13: ...K and Type J thermocouples 9VDC adapter for a 110V power supply WARRANTY INFORMATION General Tools Instruments General s DAF4207SD Anemometer Thermometer with Datalogging SD Card is warranted to the...

Страница 14: ...ntact our Customer Service to obtain an RGA Return Goods Authorization number before forwarding the unit via prepaid freight to the attention of our Service Center at this address General Tools Instru...

Страница 15: ...______ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ____...

Страница 16: ...6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com DAF4207SD User s Manual Specifications subject to change without notice 2010 GENERAL TOOLS INSTRUMENTS...

Отзывы: