MAINTENANCE, TROUBLEShOOTING 

AND CUSTOMER SUPPORT

CHANGING BATTERIES

When the red LED labeled “Low Battery” is illuminated, it’s time to
 replace the unit’s four AA” Alkaline batteries.

To replace the batteries, first use a Phillips-head screwdriver to loosen
the screw at the bottom of the CGD900 in a counterclockwise direction.
Then open the hinged door and remove the old batteries from the two
compartments while noting their polarity orientation.

Insert two fresh batteries in the right compartment (+) end first, and
then insert two more in the left compartment (-) end first. To help you
do this correctly, there are (-) and
(-)  marks  on  the  hinged  door.  Be
sure each mark ends up adjacent
to the end of a battery with match-
ing polarity (see figure).

NOTE:

If you may not be using the CGD900 for months,

remove at least one battery to avoid the possibility of
battery leakage ruining the unit.

REPLACING THE SENSOR

To replace the CGD900’s sensor, which is at
the end of the probe, first unscrew its metal
cover counterclockwise. Then gently pull out
the old sensor, which has four leads. Finally,
install the new sensor by aligning the notch
in the sensor’s socket with the raised tab on
the socket holder (see figure).

NOTE:

Do not force the sensor into the socket. Mis-

alignment can damage the sensor pins. Insert the new
sensor into the socket by pushing it directly in, without
twisting.

6

Replace the leak test vial when its contents no longer 
appear green. 

 

 

 

MAINTENANCE, TROUBLESHOOTING AND 
CUSTOMER SUPPORT 

 

Changing batteries 

When the red LED labeled “Low Battery” is illuminated, it’s time to 
replace the unit’s four AA” Alkaline batteries. 
 
To replace the batteries, first use a Phillips-head screwdriver to loosen 
the screw at the bottom of the CGD900 in a counterclockwise direction. 
Then open the hinged door and remove the old batteries from the two 
compartments while noting their polarity orientation. 
 
Insert two fresh batteries in the right compartment (+) end first, and 
then insert two more in the left compartment (-) end first. To help you 
do this correctly, there are (-) and (-) marks on the hinged door. Be sure 
each mark ends up adjacent to the end of a battery with matching 
polarity (see figure). 
 
 

 

 

 
 
 

Note: If you may not be using the CGD900 for months, remove 
at least one battery to avoid the possibility of battery leakage 
ruining the unit. 

 

Polarity Mark

 

CGD900 Manual_FINAL2_091410:Layout 1  9/14/10  1:32 PM  Page 6

Содержание CGD900

Страница 1: ...ed In MetHane aIr only Please read this manual carefully and thoroughly before using this product CGD900 Manual_FINAL2_091410 Layout 1 9 14 10 1 32 PM Page 1 99 Washington Street Melrose MA 02176 Phon...

Страница 2: ...4 Operation Instructions 4 5 Maintenance Troubleshooting and Customer Service 6 Changing the batteries 6 Replacing the sensor 6 Specifications 7 Replacement Parts and Supplies 7 Warranty Information...

Страница 3: ...u decide whether it is large enough to be worth plugging The read ing which is independent of the unit s sensitivity level rises and falls with the amount of combustible gas sensed at the end of the C...

Страница 4: ...the on off button once to turn on the unit and again to turn it off 2 WARM UP Once the unit has been turned on it automatically begins heating the sensor During warm up the digital leak size indicato...

Страница 5: ...LED labeled HI To lower the sensitivity level press the SENS button again this lights the yellow LED labeled LO USING THE LEAK TEST VIAL The CGD900 ships with a leak test vial that lets you check whet...

Страница 6: ...sensor which has four leads Finally install the new sensor by aligning the notch in the sensor s socket with the raised tab on the socket holder see figure NOTE Do not force the sensor into the socke...

Страница 7: ...ument and 1 year for the sensor PARTIAL LIST OF DETECTABLE GASES AND VAPORS Methane Propane Ethane Butane Hydrogen Ethylene Ethanol Isobutane NOL Gasoline fumes Acetylene Methyl ether Ammonia Hydrogen...

Страница 8: ...ized personnel or misuse alterations normal wear and tear or accidental damage The defective unit must be returned to General Tools Instruments or a General au thorized service center freight prepaid...

Страница 9: ...ss Remember to include a copy of your proof of purchase your return address and your phone number and or e mail address The CGD900 Combustible Gas Leak Detector is warranted to be free of defects in m...

Страница 10: ...________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________...

Страница 11: ...________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________...

Страница 12: ...e NOTICE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS 2010 GENERAL TOOLS INSTRUMENTS 9 10 CGD900 Manual_FINAL2_091410 Layout 1 9 14 10 1 32 PM Page 12 99 Washington Street Melrose MA 02176 Phone 781 665 1...

Отзывы: