Adjustment Super Wave

With this air conditioner, 3 Airflow-directions are available and for each direction, the required sweep angle can be set.

Blowing Direction

Adjusting the Right-
Left Airflow-direc-
tion Louvres

Left Side

Centre

Right Side

Lightly move the Right-Left
Airflow-direction Louvres to
the left until they stop.

Position the Right-Left Air-
flow-direction Louvres
approx. at the centre.

Lightly move the Right-Left
Airflow-direction Louvres to
the right until they stop.

CAUTION!

Adjust the Right-Left Airflow-direction Louvres after SELECT LEVER is set to the “NEUTRAL” position.

AIR DIRECTION ADJUSTMENT

Minimum

Maximum

Minimum

Maximum

Minimum

Maximum

Содержание AKG12U

Страница 1: ...ON MANUAL FOR FUTURE REFERENCE Espa ol Portugu s English COOLING MODEL AMH13F REVERSE CYCLE MODEL AMH12U OPERATING MANUAL ROOM AIR CONDITIONER WINDOW TYPE OPERATING MANUAL MANUAL DE FUNCIONAMIENTO MAN...

Страница 2: ...s no user serviceable parts When moving consult authorized service personnel for disconnection and installation of the unit PRECAUTIONS 2 NAME AND FUNCTION OF PARTS 6 AIR CONDITIONER OPERATION 7 AIR D...

Страница 3: ...er cord Do not stand heavy items on the power cord or allow it to be pulled Such treatment could damage the insulation resulting in fire hazard and electrical shock WARNING If the power supply cord of...

Страница 4: ...he quality of the stored items may deteriorate Do not direct air flow at fireplaces or heating apparatuses Direct air blowing on fires could result in improper combustion or fire Do not set flower vas...

Страница 5: ...d possible damage Do not use inflammable gases near the air conditioner Do not touch the heat exchanger radiator fins Personal injury could result Be particularly careful when cleaning Bending or dama...

Страница 6: ...here 7 Air Filter P 13 Removes all dirt and dust from the air Control Panel When opening and closing the control panel cover press the position of PUSH by your finger 1 SELECT Lever NEUTRAL When chan...

Страница 7: ...s maximum resulting in maximum cooling effect Cooling To obtain maximum cooling effect in the hot summer select position HIGH POWER on the master control Maximum moisture removal air circulation and d...

Страница 8: ...en operating with the MASTER CONTROL switched to HIGH POWER RED or SUPER QUIET RED turn the thermostat fully clockwise 2 When operating with the MASTER CONTROL switched to HIGH POWER BLUE or SUPER QUI...

Страница 9: ...umbers NOTE When the THERMOSTAT Control switch is set at positions 5 6 or 7 comfortable room temperatures can usually be obtained Please note that it is unhealthy for the room temperature to be lower...

Страница 10: ...y manual operation Horizontal Adjustment The Right Left Airflow direction Louvres may be positioned using tabs to dis charge the air rightward leftward or straight on NOTE The THERMOSTAT positions 8 9...

Страница 11: ...Set the SUPER WAVE Switch to ON NOTE If the MASTER CONTROL Switch is set to set it to the other position 4 The sweep angle can be adjusted within the SUPER WAVE ZONE range When the SELECT LEVER is mov...

Страница 12: ...tre Right Side Lightly move the Right Left Airflow direction Louvres to the left until they stop Position the Right Left Air flow direction Louvres approx at the centre Lightly move the Right Left Air...

Страница 13: ...it by wiping with a cloth dipped in cool or warm water then wipe with another soft clean dry cloth CAUTION Never use water that is hotter than 40 C The body may warp or change colour Do not use inflam...

Страница 14: ...r During Cooling operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation a...

Страница 15: ...mputer is used to monitor this condition and when necessary the defrosting mode operates result ing in a temporary interruption of the Heating mode both indoor and outside fans will stop About 7 to 15...

Отзывы: