Plug the dust collector into a proper receptacle. Your power tools should be connected to a dedicated electrical 

circuit of not less than #14 wire and should be protected with a 15 amp time lag fuse. If an extension cord is needed 

use only 3 wire cords with 3-prong grounded type plugs and 3-pole receptacles. Consult the chart below for details 

on selecting an extension cord.

GROUNDING

This dust collector must be grounded to protect the operator from electrical 
shock. It has a 3-conductor cord and 3-prong grounded plug   to fit a ground-
ed-type receptacle  . Do not attempt to modify the plug or remove the 3rd 
prong (grounding pin) from the plug to make it fit into an old 2 hole wall sock-
et or extension cord. If an adaptor is used it must be attached to the metal 
screw of the receptacle  . 

Note: The use of an adaptor plug is illegal in some areas. Check your local 

codes. If you have any doubts or if the supplied plug does not correspond 

to your electrical outlet, consult a qualified electrician before proceeding. 

TABLE - MINIMUM GAUGE FOR CORD

VOLTS

110 V

MORE 

THAN

18
18
16
14

220 V

AMPERE  

RATING

NOT 

MORE 

THAN

0
6

10
12

6

10
12
16

16
16
16
12

16
14
14

-

14
12
12

-

25 ft.
50 ft.

50 ft.

100 ft.

100 ft.
200 ft.

150 ft.
300 ft.

TOTAL LENGTH OF CORD IN FEET

AWG

BEFORE CONNECTING THE DUST COLLECTOR TO A POWER SOURCE, MAKE SURE THAT THE ELECTRICAL CURRENT 

IS OF THE SAME TYPE AS THAT STAMPED ON THE MOTOR NAMEPLATE. ALL ELECTRICAL CONNECTIONS SHOULD 

HAVE A PROPER CONTACT. NEVER CONNECT THE MACHINE TO A POWER SOURCE OF GREATER OR LOWER VOL-

TAGE THAN NEEDED. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY TO THE USER AND/OR DAMAGE TO 

THE MACHINE. IF IN DOUBT, CONTACT A QUALIFIED ELECTRICIAN BEFORE CONNECTING TO THE POWER SOURCE. 

5

   ELECTRICAL REQUIREMENTS   

 

BEFORE CONNECTING THE MACHINE TO THE POWER SOURCE, VERIFY THAT THE VOLTAGE OF YOUR POWER SUPPLY CORRE-

SPONDS WITH THE VOLTAGE SPECIFIED ON THE MOTOR I.D. NAMEPLATE. A POWER SOURCE WITH GREATER VOLTAGE THAN 

NEEDED CAN RESULT IN SERIOUS INJURY TO THE USER AS WELL AS DAMAGE TO THE MACHINE. IF IN DOUBT, CONTACT A 

QUALIFIED ELECTRICIAN BEFORE CONNECTING TO THE POWER SOURCE.

THIS TOOL IS FOR INDOOR USE ONLY. DO NOT EXPOSE TO RAIN OR USE IN WET OR DAMP LOCATIONS.

Содержание 10-110

Страница 1: ...odels Safety switch with key prevents unit from being started when key is removed Heavy duty collection bags made from extra thick transparent recyclable plastic SPECIFICATIONS INLET DIAMETERS 1 6 152...

Страница 2: ...riod of 24 months from date of purchase any genuine part or parts which upon examination prove to be defective in workmanship or material In order to obtain this warranty all defective parts must be r...

Страница 3: ...rd 2 year Limited Warranty or under our Limited Lifetime Warranty all defective parts components or machinery must be returned freight or postage prepaid to General International or to a nearby distri...

Страница 4: ...ng or with the power on 14 To avoid health hazards from vapors or dusts do not vacuum toxic material 15 Do not insert hands or fingers or any foreign objects into ventilation inlet and outlet openings...

Страница 5: ...re proceeding TABLE MINIMUM GAUGE FOR CORD VOLTS 110 V MORE THAN 18 18 16 14 220 V AMPERE RATING NOT MORE THAN 0 6 10 12 6 10 12 16 16 16 16 12 16 14 14 14 12 12 25 ft 50 ft 50 ft 100 ft 100 ft 200 ft...

Страница 6: ...S AND COMPONENTS 2 HP DUST COLLECTOR 10 110 or 10 110CF OR CONNECTOR DRUM COLLECTOR BODY W MOTOR ASS Y BASE PLATE HOSE INLET Y FITTING FILTER BAG 10 110 ONLY CANISTER FILTER 10 110CF ONLY COLLECTOR BA...

Страница 7: ...E THAT ADEQUATE HEARING PRO TECTION IS USED AND THAT THE OVERALL SOUND LEVEL WITHIN THE WORKING ENVIRONMENT IS TAKEN INTO CONSIDERATION ADDITIONAL REQUIREMENTS FOR SETUP ASSEMBLY Flat piece of wood su...

Страница 8: ...collector in your shop HOSES AND DUCTING RUNNING ALONG THE SHOP FLOOR BETWEEN MACHINERY CAN CAUSE USERS TO TRIP AND LEAD TO SERIOUS INJURY LAYING OUT A PLAN FOR THE PIPING For permanent installations...

Страница 9: ...ket and place it over the opening of the connector Take the drum and proceed by placing it over the same opening STEP 4 ATTACH THE DRUM Note The vertical support rod has an angled end A to seat over t...

Страница 10: ...S WHEN HANDLING METAL PARTS SUCH AS BELT CLAMPS WHICH CAN CUT IF HANDLED CARELESSLY Basic assembly is now complete and your dust col lector is ready to be put into service Once the unit is hooked up t...

Страница 11: ...D REMOVE THE SWITCH KEY WHENEVER THE DUST COLLECTOR IS NOT IN USE PLACE IT IN A SAFE PLACE AND OUT OF THE REACH OF CHILDREN 11 This machine operates on 220 V single phase power M1 model only if you su...

Страница 12: ...er filter may become clogged and affect airflow as well the overall efficiency of the unit Should you notice a drop in the efficiency or performance of the unit it may be a sign that it is time to cle...

Страница 13: ...website at www general ca 4 to 2 1 2 Reducer 10 086 1 Micron Canister Filter 10 106C 4 x 10 Polyethylene Flexible Hose 10 410 4 x 50 heavy duty polyethylene flexible hose 10 130 Clear Plastic Collecto...

Страница 14: ...28 17A 25 30 12 18 2 11A 10A 9 6A 13 5 29 4A 1 2 32 33 2 23 2 28 2 27 34 24 34 22 16 15 12 31 2 19 35 7A 26A 29A 36 14...

Страница 15: ...0 19 CONNECTOR 1 22 10110 22 COLLECTOR BAG ITEM 10 120 1 23 10110 23 VERTICAL SUPPORT ROD 1 24 10110 24 DRUM 1 25 10110 25 GASKET 1 26A 10110 26A HANGER 1 27 10110 27 FILTER 1 28 10110 28 FOAM GASKET...

Страница 16: ...P 3 4 1 10106C 31 CANISTER FIXING PLATE 2 10106C 32 BEARING 1206 2 10106C 35 FLAPPER 3 10106C 36 SPINDLE 1 PART DESCRIPTION SPEC QTY 10106C 38 ROUND HEAD SCREW M5X6 6 10106C 39 FIXING PLATE 2 10106C 4...

Страница 17: ...17 Notes...

Страница 18: ...Champ d Eau Montreal Quebec Canada H1P 1Y3 Tel 514 326 1161 Fax 514 326 5565 Parts Service Fax 514 326 5555 Order Desk orderdesk general ca www general ca MODEL 10 110 10 110CF 10 110CF 10 110 Follow...

Отзывы: