background image

6

 GB

To clear the record,

1. Press the wind speed and direction window.

2. Press and hold [MEMORY].

As for the wind direction, it is displayed in a digital compass with
bearing readouts.

WEATHER ALARMS

Weather alarms are used to alert you to certain weather conditions.
Once activated, the alarm will go off when a certain set criterion is
met.

You can set alarms for:

· Indoor, outdoor and channel high temperatures

· Indoor, outdoor and channel low temperatures

· Indoor, outdoor and channel dew point approaching

· Indoor, outdoor and channel high humidity

· Indoor, outdoor and channel low humidity

· High rainfall rate

· Pressure drop

· High gust wind

· Low wind chill

To set a weather alarm,

1. Press the window containing the weather element you want to

set.

2. Press [ALARM]. The current alarm setting will be displayed.

3. Press and hold [SET].

4. Press [

U

] and [

V

] for the desired setting.

5. Press [SET].

For temperatures and humidity, the high and low alarms can be set
in sequence. After entering the value for one alarm, you will be
prompted to enter the value for the other.

A weather alarm is activated once set. When the set criteria is met,
an alarm will go off and the current reading will flash together with
the corresponding indicator.

If that happens in the outdoor/channel temperature or humidity
window, the “OUT”  indicator will flash to show that the criteria set
for the outdoor thermo-hygrometer has been met. If it is one of the
separate sensors, the [CHANNEL] indicator will flash. Press the
window repeatedly to locate the channel in question.

When a weather alarm goes off, press any button to stop the alarm.
The alarm is still active until you deactivate the function or the
criteria is no longer met.

To do so,

1. Press the window containing the weather element you want to

set.

2. Press [ALARM].

3. Press [ALARM ON/OFF]  to deactivate the function.

To turn on the function again, simply follow the same procedure
and press [ALARM ON/OFF].

AUTO SCANNING FUNCTION

The auto scanning function is avalibable for the outdoor/channel
window for both the temperature and humidity.

To use it,

1. Press the outdoor/channel temperature or humidity window.

2. Press and hold [

U

] . The main unit will start scanning from the

active temperature and humidity display. Each channel will be
displayed for about 4 seconds.

To exit the auto scanning routine, press any window or control
button.

RAINFALL

The rate of rainfall can be displayed in mm/hr or in/hr.

To select the display unit,

1. Press the rainfall window.

2. Press [UNIT] for the desired setting.

To display the yesterday’s rainfall and the total rainfall from the
last cleared date,

1. Press the rainfall window.

2. Press [MEMORY] for the desired record. Yesterday rainfall will

be displayed with “YESTERDAY” shown in the rainfall window.
Total rainfall will be displayed with "TOTAL" shown in the
rainfall window. The time and date of the record will be displayed
alternatively with “SINCE” icon in the clock window for total
rainfall.

Note: Yesterday’s rainfall record will be updated when the real time
clock runs from 11:59:59 pm to 12:00:00 am. And it is counted for
12:00:00 am of one day to 12:00:00 am on the next day.

If the rain sensor detects no rainfall for about two consecutive
hours, the current rate of rainfall will be displayed as zero.

To clear the total rainfall,

1. Press the rainfall window.

2. Press and hold [MEMORY] till the key tone is heard.

The yesterday’s rainfall record will not be affected when you clear
the total rainfall.

WIND SPEED AND DIRECTION

The current wind speed and direction are displayed in the wind
speed and direction window.

To display the average wind speed, press the window till the
“AVERAGE” icon is displayed.

The wind speed can be displayed in m/s, kph, mph or knots.

To select the display unit,

1. Press the wind speed and direction window.

2. Press [UNIT] for the desired setting.

To display the maximum speed and direction for gust wind in
record,

1. Press the wind speed and direction window.

2. Press [MEMORY]. The time and date of the record will also be

displayed aternatively with “STAMP” icon in the clock window.

928N-USE.p65

08/10/2001, 12:20 PM

6

Содержание Cable Free WMR968

Страница 1: ...TR938 The WMR968 can support up to seven different remote instruments You can also connect up to three optional thermo or thermo hygro sensors to the system Optional items include Thermo hygro sensor...

Страница 2: ...check the leveling 5 Use metal ring to adjust the leveling of the rain collector if necessary 6 Close the cover of the rain collector THE SOLAR TRANSMITTERS The solar transmitters make use of solar e...

Страница 3: ...optional remote thermo and thermo hygro sensors Replace the batteries when the respective indicators light up Note The readings collected from the thermo hygrometer and any optional remote thermo and...

Страница 4: ...sired setting 7 Press SET to confirm Note the window will show if no alarm is armed Once set the alarm clock will be activated automatically and the alarm indicator will light up When an alarm goes of...

Страница 5: ...of detecting the dew point temperature as well as the wind chill reading To display such information press the window repeatedly The temperatures can be displayed in degree Centigrade C or Fahrenheit...

Страница 6: ...uto scanning function is avalibable for the outdoor channel window for both the temperature and humidity To use it 1 Press the outdoor channel temperature or humidity window 2 Press and hold U The mai...

Страница 7: ...rosive materials Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit 3 Do not subject the unit to excessive force shock dust temperature or humidity Such treatmen...

Страница 8: ...nterference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferencetoradioortelevisionrece...

Отзывы: