3. SCREW CALIBRATION
Screws are to be fastened exclusively using a torque wrench.
* Achieve coupling torque tightening screws at the same time.
The screws in positions 1, 22 and 26 must be tightened with a torque wrench and the
Threaded shaft must be lubricated with molybdenum disulphide grease, part #F12001500
** The supports diagram fixing screws fig. 131 must be tightened in two steps:
1st step = 29.5 ft. lbs. (40 Nm) according to the sequence indicated;
2nd step= 29.5 ft. lbs. (40 Nm) (calibration check repeating the sequence indicated)
*** The head fixing screws must be tightened respecting the phases and order shown in the
diagram in Fig. 132.
**** The liner fixing screws must be tightened respecting the phases and order shown in the diagram
in Fig. 132.
Page 37
GENERAL PUMP
A member of the Interpump Group
SMH SERIES
Description
Exploded View Position
(From Owner’s Manual)
Fastening
Ft. Lbs.
Fastening
Nm
Casing cover M10x30 screw
79
33.2
45
G1/2x13 casing plug
81
29.5
40
Lifting bracket M16x30 screw
44
147.5
200
Reduction gear cover M10x40 screw
72
33.2
45
Ring gear stop M10x25 screw
67
59.0
80
Reduction gear box M10x40 screw
72
33.2
45
Upper cover M6x14 screw
52
7.4
10
Bearing cover M10x30 screw
79
33.2
45
M10x1.5x80 screw for conrod tightening
46
47.9
65*
Plunger guide screw M6x20
40
7.4
10
Plunger assembly
15
29.5
40
Choke fitting D.3 3/8M-3/8F
29
33.2
45
Supports screw M8x100
22
29.5
40**
Head M16x280 screw
1
206.5
280***
Liner M10x140 screw
26
61.2
83***8
Lower cover M6x40 screw
86
7.4
10
Ref 300894 Rev. B
05-22