background image

INTRODUCTION

Thank you for purchasing a GENERAL PUMP Pressure

Washer Pump. With proper installation and maintenance

it  will  provide  you  with  many  years  of  dependable, 

trouble-free service.

This  manual  was  developed  as  a  basic  guide  to 

understanding  the  operation  and  requirements, 

installation, and servicing of GENERAL PUMP positive

displacement pumps.

Pressure cleaning equipment is potentially hazardous

and could cause personal injury or property damage if 

installed, repaired, or operated in an unsafe manner, or in

a manner which is not consistent with the manufacturer’s

recommendations or requirements.

There  are  many  manufacturers  of  pressure  washer

pumps and complementary components. Be sure that the

required components you choose to use are consistent

with  the  high  quality  standards  of  GENERAL PUMP

pumps.

GENERAL PUMP  does  not  assume  liability  or 

responsibility  for  the  design  of  a  customer’s  high 

pressure system.

TYPICAL OPERATION AND

REQUIREMENTS

PRESSURE

The pressure produced in a pressure washer 

system is the result of forcing a known volume 

(or flow) of water through a known size orifice 

(spray tip). Pressure is measured in pounds per 

square inch (PSI).

FLOW

The flow or volume produced in a pressure washer 

system is determined by the speed that the pump 

shaft is rotated (RPM). The faster the shaft is 

rotated, the higher the output volume. Flow or 

volume is measured in gallons per minute (GPM).

The pump, which is driven by an electric motor or a gas

engine, draws or accepts filtered water in through a se-

ries of inlet check valves as the plungers move back. As

the plungers move forward, the inlet valves close, forcing

the water to travel through a series of outlet check valves,

and to the outbound side of the pump.

After the water exits the pump, its flow direction must be

controlled  with  an  unloading  or  regulating  valve.  A 

positive  displacement  pump  is  always  delivering  a 

certain volume of water whether the spray gun is open

or closed, therefore a device is needed to control the di-

rection of flow, either allowing the flow to go through the

open spray gun, or redirecting (by-passing) the flow back to

the inbound side of the pump when the spray gun is closed.

Without an unloading or regulating valve, dangerously high

pressures will be produced when the spray gun is closed

because the water being forced out of the pump has no

place to go. Serious bodily injury or property damage could

be caused by failure to properly utilize an appropriate un-

loader or regulator valve in your pressure washer system.

As a safety device, at least one pressure relief valve should

be installed in the outbound side of the pump to guard

against failure of component parts, and the development of

dangerously high pressures.

Cleaning chemicals or detergents may be introduced into

the flow of water either inbound or outbound of the pump.

An inbound or  upstream type of chemical injector simply

uses the pump’s ability to draw or suck fluid in to introduce

a chemical into the stream of water. Care must be taken to

avoid introducing any chemicals which are not compatible

with the materials in the pump and downstream compo-

nents. An upstream injector does allow chemicals to be ap-

plied  to  the  work  surface  at  the  normal  high  working

pressure of the system. An outbound or downstream type of

chemical injector uses a venturi (very similar to that used in

an automotive carburetor) to draw a chemical into the water

stream. A downstream injector requires low pressure to ac-

tivate chemical flow. Low pressure is achieved by chang-

ing to a large sized spray tip, or opening up a large orifice

at the outlet end of the spray gun using an adjustable noz-

zle or a double lance. There are several advantages to

using a downstream injector over using an upstream type.

1. Fewer component parts are exposed to the cleaning

chemicals, extending system life.

2. The operator can control the flow of chemical (on and

off) by changing the system pressure at the nozzle.

3. Applying chemical at low pressure is more 

economical because less chemical bounces off the 

work surface.

Heated pressure washers and steam cleaners increase

the ability of a high pressure flow of water to break down

dirt and grease. They also increase the action of most

cleaning chemicals. These systems are very comples,

and add more potential personal injury and property 

damage hazards. Design of these systems requires many

more additional components as well as experienced de-

sign personnel with knowledge of fuels, heat transfers,

electronics, etc.

2

Содержание Pressure Washer System

Страница 1: ...tream or Inlet Side Pressure 2 Components 6 Flow 2 Downstream or Outlet Side Designing Your System 3 5 Components 6 7 Pump Selection 3 Installing Your Components 7 8 Motor Engine Selection 3 Troubleshooting 9 Determining Spray Tip Size 5 Servicing Your Pump 10 11 Drive System 5 6 Valve Assemblies 10 Pulley Selection 5 Removing Manifold Head 10 Belt Selection 6 Replacing Plungers 11 Replacing Packi...

Страница 2: ... the spray gun is closed Without an unloading or regulating valve dangerously high pressures will be produced when the spray gun is closed because the water being forced out of the pump has no place to go Serious bodily injury or property damage could be caused by failure to properly utilize an appropriate un loader or regulator valve in your pressure washer system As a safety device at least one ...

Страница 3: ...your work surface instead of cleaning it Never exceed the maximum pressures of ro tation speed as is stated on the Technical Data Sheet supplied with each pump Refer to the Pump Data Sheet to determine what pump RPM is needed to deliver your required GPM output MOTOR ENGINE SELECTION The size of the electric motor or gas engine required to drive your pump is determined by the pump GPM and PSI outp...

Страница 4: ...5 5 060 55 87 1 40 1 90 2 10 2 30 2 50 2 8 3 0 3 4 3 8 4 4 4 8 5 2 5 5 6 062 60 95 1 50 2 10 2 30 2 50 2 70 3 0 3 2 3 7 4 2 4 8 5 2 5 6 6 0 6 5 064 65 1 00 1 70 2 30 2 50 2 70 2 90 3 3 3 6 4 0 4 6 5 2 5 7 6 0 6 5 7 067 70 1 10 1 80 2 50 2 70 2 90 3 10 3 5 3 8 4 3 5 0 5 6 6 1 6 6 7 0 7 5 707 75 1 20 1 90 2 70 2 90 3 20 3 40 3 8 4 1 4 6 5 3 6 0 6 5 7 0 7 5 8 072 80 1 30 2 00 2 80 3 10 3 40 3 60 4 0 ...

Страница 5: ...performance using a tip that is sized too small will allow overpressurization of the pump and components You must know your output GPM and your desired output PSI to properly select a spray tip size To use the chart on page 4 find the desired PSI read down the column until you find the output GPM closest to your pump application Read to the far left to find the spray tip number and orifice diamete...

Страница 6: ...low of water without restricion Thermal Relief Valve This is a temperature sensing valve that opens and dumps water to the atmosphere at a predetermined temperature Recirculating water through the by pass loop has a tendency to heat up to temperatures that can eventually damage internal pump parts A thermal relief valve is an inexpensive way to avoid costly repairs Upstream Injector A device which...

Страница 7: ...njector will not draw any chemical Downstream injectors require low pressure generally about 200 PSI to activate the chemical flow A double nozzle holder rollover nozzle and a double lance are a few accessories that allow mounting a low pressure spray tip as well as the standard high pressure spray tip An adjustable nozzle allows a large orifice to be opened around the high pressure spray tip High...

Страница 8: ... Mount the motor engine in relationship to the pump such that when running the rotation of the pump crankshaft is counterclockwise as you face the pump crankcase or pulley A gas engine has only one rotation direction which may vary between manufacturers Be sure you know the rotation direction before you begin assembly Most electric motors may be operated in either rotation direction by changing th...

Страница 9: ...gs Oil leaking in the area of crankshaft Worn crankshaft seal or inproperly installed oil seal o ring Remove oil seal retainer and replace damaged o ring and or seals Bad bearing Replace bearing and any spacer or cover damaged by heat Excessive play in the end of the crankshaft pulley Worn main bearing from excessive tension on drive belt Replace crankcase bearing and or tension drive belt Water i...

Страница 10: ...ed 7 Install new o rings in valve cavity 8 Insert assembly into valve cavity 9 Replace valve cap and torque to specifications REMOVING MANIFOLD HEAD Figure 2 1 Remove the fasteners retaining the head 2 Separate head from crankcase NOTE It may be necessary to tap head lightly with rawhide mallet to loosen CAUTION When sliding head from crankcase use caution not to damage plungers 3 The V packing as...

Страница 11: ... this is replaced before new plunger is installed 3 Separate piston screw from plunger 4 Install new o ring and teflon backup ring on piston screw NOTE A film of grease on the outside of the o rings insures a better installation 5 Carefully press piston screw into plunger 6 Slide new plunger over the piston guide and torque to specifications 11 3 5 6 ...

Страница 12: ...er until it will go no further using proper insertion tool Install rear head ring v packing and main seal retainer into cylinder in order shown and press firmly into cylinder 5 Repeat this sequence for each cylinder 6 Coat each plunger with grease and carefully remount manifold Torque head to specifications General Pump is a member of the Interpump Group G GE EN NE ER RA AL L P PU UM MP P 1174 Nor...

Отзывы: