4
Turn on the piano, while holding down the REC button until the display shows:
|READY TO UPDATE |
| |
Click with the mouse on the GO! button or, from the ACTION menu, select EXECUTE
(ALT+A, E). The piano display appears as follows:
|TESTING... |
|n1/n2 PACKETS |
At the end of the test the following display appears:
| TEST OK |
| |
After a short time, the following display appears:
|ERASING... |
| |
You are now erasing the old operating system from FLASH memory. When the system
is erased, the following display appears as your new operating system is installed into
Flash Memory:
|UPDATING... |
|n1/n2 PACKETS |
When the entire update procedure is completed, the following display appears:
|UPDATE_OK:SWITCH|
|POWER TO RESTART|
The update has now been successfully completed. Turn off the power switch on the
piano, and turn it back on again to use your updated instrument.
RP100-150 Some Repairing Tips
Operation Descriptions
Display
This message could be appear if an error occur on the communication channel.
Possible solutions:
1) inconsistent data received on MIDI or COMPUTER input socket, check the ratings of
the device connected to the piano.
2) if the error persist, try to replace Outputs Board first and CPU board second.
|MIDI SCI error |
| |
This message could be appear if an error occur on the communication channel.
Possible solutions:
1) verify all the connections between Keyboard Interface Board and the CPU board.
2) if the error persist, try to replace Keyboard Interface Board first and CPU board
second.
|VALIS SCI error |
| |
This message could be appear if an error occur on the communication between CPU
and DISP3 chips.
Possible solutions:
1) verify all the tracks, solders and components between CPU and DISP3 chips as
shown in schematics.
2) if the error persist, replace the CPU board and send back to generalmusic the failed
CPU board.
|Disp Failure |
| |
Operation Descriptions
Display
The procedures that follow must be executed subsequently in the order specified.
Before turn on the instrument check the jumpers setting on CPU & SOUND
GENERATOR BOARD corresponds at the model accordingly to the following table:
MODEL J4 J5 J3 J6 J2
RP200 GEM 1-2 1-2 1-2 1-2 1-2
RP200 BALDWIN 1-2 1-2 1-2 1-2 2-3
GRP300 GEM 1-2 1-2 1-2 2-3 1-2 ** v.2.00 or greater
GRP300 BALDWIN 1-2 1-2 1-2 2-3 2-3 ** v.2.00 or greater
Remove the secondary fuses F1, F2, F3, located on POWER AMPLIFIER & SUPPLY
BOARD; turn on the instrument and verify the supply AC voltages:
(CN6) between pin1 and pin2 = 27,5±1,5Vac
(CN6) between pin1 and pin3 = 27,5±1,5Vac
(CN6) between pin2 and pin3 = 55±3Vac
(CN12) between pin1 and pin2 = 16±0,8Vac
(CN12) between pin1 and pin3 = 16±0,8Vac
(CN12) between pin2 and pin3 = 32±1,6Vac
Turn off the instrument, and put the fuses back on its holders.
Turn on the instrument and the appropriate welcome message appears on the display.
A few seconds later the led GRAND PIANO light.
Check the supply DC voltages on CPU & SOUND GENERATOR BOARD:
(CN8) between pin9 and pin7 = +5±0,25Vdc
(CN8) between pin1 and pin4 = +12±0,6Vdc
(CN8) between pin1 and pin5 = -12±0,6Vdc
|INTERNAL PRESET|
| GRAND PIANO |
|GR.PIANO sel.:1|
RP200 AUTOTEST PROCEDURE
Operation Descriptions
Display
The instrument starts in AUTOTEST mode turning on the instrument while pressing
down the "GRAND PIANO" button (pressing PRESET instead GRAND PIANO the
procedure starts from LCD display test).
NOTE: Each time you press the "GRAND PIANO" button the autotest procedure
proceeds to the next step.
| RP98 |
| AUTOTEST |
| |
Set the default display contrast in the ±6 range by pressing the DATA + or - buttons.
|CONTRAST = # |
| |
| |
The instrument shows the date, time and release version of the software loaded in
flash memory.
| mmm dd yyyy |
|hh:mm:ss V #.##|
| |
The instrument asks if you want to update it, press GRAND PIANO to skip, the
appropriate procedure to update the software is explained further.
|EPROM to FLASH |
|push REC to prog|
| |
The instrument performs the flash memory data checksum and display it in
hexadecimal value.
NOTE: the BT (boot) value must be EAAB for ver.2.00, if it does not correspond you
can not update software thru serial port but only with Update Software Board see
more further.
|Wait * |
|Eprom Checksum |
| |
|cks BT PR ALL|
| #### #### ####|
| |
The instrument performs the "LIBRARY" Rom memory data checksum and display it in
hexadecimal value.
|Wait * |
|Library Checksum|
| |
|Wait ok! |
|Checksum: A021|
| |
The instrument performs the RAM memory test showing the address checked.
|RAM MEMORY CHECK|
|addr 23BFFF OK|
| |
The LCD display test fades from light to dark and viceversa.
|
❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚
|
|
❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚
|
|
❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚
|
Check that all leds are lighting.
|--- LED TEST ---|
|Are all leds on?|
| |
RP200 INITIAL CHECK
| RP200 |
| REALPIANO |
| GEM |
| PIANOVELLE |
| RP200 |
| BALDWIN |
| GRP300 |
| REALPIANO |
| GEM |
| PIANOVELLE |
| GRP300 |
| BALDWIN |
Содержание GRP300 BALDWIN
Страница 6: ...J J J J J 6 ...
Страница 7: ...7J J J J J ...
Страница 8: ...J J J J J 8 ...
Страница 9: ...9J J J J J ...
Страница 10: ...J J J J J 10 ...
Страница 11: ...11J J J J J ...
Страница 12: ...J J J J J 12 ...
Страница 13: ...13J J J J J ...
Страница 14: ...J J J J J 14 ...
Страница 15: ...15J J J J J CPU SOUND GENERATOR BOARD PCB 310603 1 ...
Страница 16: ...J J J J J 16 ...
Страница 17: ...17J J J J J ...