![General Monitors IR4000M Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/general-monitors/ir4000m/ir4000m_programming-instruction-manual_2210548028.webp)
Model IR4000M
28
1.5.4 Gas Selection (Read-Only)
A Read command to this register returns the present gas selection for the
detector.
Table 17. Gas Selection Codes
Code (decimal or hex)
Gas Type
0
Methane
1
Propane
2
N-Butane
3
Hexane
4
% by volume Methane
5
Other
6
Ethane
7
Pentane
1.5.5 Model Type ( Read-Only)
A Read returns the model type for the detector, which is 2104 for IR400.
1.5.6 Display ( Read-Only)
A read returns two ASCII characters which can be displayed by IR4000, such as
gas concentration, fault code or device status (AC, CP or SU)
1.5.7 Cal IO type (Read-Only)
A Read returns Calibration input type: 0 – for LED switch, 1 – for manual
solenoid and 2 for ARCG (automatic solenoid)
1.5.8 Solenoid State (Read-Only)
A Read returns solenoid state of the unit : 10 – solenoid is On, 20 – solenoid is
Off, 30 – solenoid is disabled (Cal IO type is LED switch).