![General International AC1104 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/general-international/ac1104/ac1104_setup-and-operation-manual_2210399011.webp)
ENGLISH
11
141204
5. Drain all moisture from air tank(s).
6. Fully close drain valve(s).
7. Protect electrical cord and air hoses from damage (such as being
stepped on or driven over). Wrap all cords and hoses loosely around
air compressor.
8. Place air compressor in a cool, dry, safe, and indoor location.
Always inspect the tool before use, and make sure it is in good working
condition. Make sure all air vents are clear, (use compressed air to clean
the machine where possible). Check the power cable to make sure it is
intact and free from cracks, bare wires etc. Avoid using solvents when
cleaning plastic parts, most plastics are susceptible to damage from the
various types of commercial solvents.
TROUBLESHOOTING
TROUBLE
POSSIBLE CAUSE
CORRECTIVE ACTION
Compressor Will Not Start
1. Blown fuse or circuit breaker
tripped
2. Loose electrical connections
1. Replace or reset fuse/circuit
breaker
2. Check wiring connections
Low Pressure
1. Restricted air filter
2. Defective check valve
3. Air leak in safety valve
1. Replace air filter
2. Replace check valve
3. Check valve by pulling on ring. If
condition persists, replace valve.
Safety Valve Releasing
1. Defective Pressure Switch
1. Replace pressure switch
Oil Discharge in Air
1. Too much oil in crankcase
2. Compressor overheated
3. Restricted oil breather cap
1. Drain crankcase and refill to prop
-
er level on oil sight glass
2. Reduce air pressure regulation
3. Clean or replace oil breather cap
Содержание AC1104
Страница 13: ...ENGLISH 13 141205 SCHEMATIC DRAWING ...
Страница 14: ...ENGLISH 14 ...
Страница 28: ...FRANÇAIS 28 SCHÉMA ...