Installation and Setup
076R155-000
SpectraComm 553 Fractional T1 DSU
2-3
Issue 7
Installation and Operation Manual
shows the Universal Zone 1 backplane for an SC 5000 shelf. This backplane provides
network interfacing for the shelf-resident modules through six 50-pin connectors.
Figure 2-2
Universal Back Plane for SpectraComm 5000 Shelf, Zone 1
SC 2000 Shelf Back Panel
shows the back panel of the SpectraComm 2000 shelf. The connectors for
each card slot
(1 and 2) are described below.
Figure 2-3
SpectraComm 2000 Shelf Back Panel
Note
In order to comply with FCC Part 15 standards for a Class A device, an SC 553 DSU installed in an SC
2000 shelf requires shielded cables at the network interface and at the cascade port interface (if it is in-
stalled). The required cables are available from GDC as Part Nos. 027H251-XXX and 027H245-XXX.
100 - 120VAC
4A 50-60Hz
220 - 240VAC
2A 50-60Hz
J
50
J51
J49
CAUTION HIGH VOLTAGE
DISCONNECT POWER
BEFORE SERVICING
THIS ENCLOSURE MAY CONTAIN FCC
REGISTERED EQUIPMENT. SPECIFIC
REGISTRATION INFORMATION IS
CONTAINED ON INDIVIDUAL UNITS
S/N
MODEL:
MS - 1
General DataComm, Inc.
Middlebury, CT
.
LISTED
TB1
1
EXT RING
EXT -V BAT
GND F
GND RING
GND BAT
J17
UNIVERSAL BACKPLANE
J20
J1
J2
J3
J5
J6
J7
J21
J18
J8
J9
J10
J11
J12
J19
J22
J52
J13
J14
J15
J16
Term 2
Term 1
Business Equip 2
ON OFF
NTWK 1A
NTWK
1
B
NTWK
2A
NTWK 2B
ALARM
Top Bottom
Business Equip 1
SCM 1
SCM 2
-60VDC 0.5A
-48VDC 0.5A
+24VDC 1.0A
NO
NC
C
+
+
_
_
BATT B BATT A
Business Equip
n
DB25 female for connection of DTE equipment. V.35 interface is standard:
EIA 530 interface is available as an option.
NTWK
n
A
RJ48C jack for network interface connection (shielded cable)
NTWK
n
B
RJ48C jack for station clock or for cascade port interface connection when
cascade option is installed (shielded cable)
Term
n
RJ45 jack for RS561 terminal interface connection.; if only one card is
installed, connection must be made to Term connector for the occupied
slot; if two cards are installed, connection to either Term connector can
access both.