Wallmount Enclosure

1-7

                                                                                                                                           GDC 086R601-001

Ground Start Ground

For OB (FXS) voice circuits that use ground start signaling, an explicit ground connection must 
be made between the Metroplex 6000 and the switching equipment (PBX). Ground start FXS 
works by connecting the Ring lead of the telephone circuit to earth ground causing current to flow 
in the Ring lead but not in the Tip lead. On the Metroplex 6000, OB voice channels configured 
for ground start FXS connect the positive pole of the battery to the rear panel terminal block 
position labeled GS GND. This position must be connected to the switching equipment (PBX) 
common ground. By default, it is shorted to chassis ground. 

Power Supply Redundancy

The Metroplex 6000 Wallmount Enclosure contains an internal AC input power supply which 
provides a regulated 24 VDC supply to the cards in the enclosure. To provide for power supply 
redundancy, an optional external source of 24 VDC may be connected to terminal block TB2 
labeled EXT. POWER. The recommended power source is International Power Sources, Inc. 
Model No. PUP110-14.

Connect the black (negative) wire to the terminal labeled -BATT and the red (positive) wire to 
the terminal lBATT. 

If the Metroplex 6000 internal power supply fails, this external power supply may be used to 
provide power without interruption. A power supply alarm message is displayed on the local 
manager VT-100 screen as 

INT. P.S. FAIL

Similarly, if the external supply fails or is disconnected, an alarm message 

EXT. P.S. FAIL

appears, and the internal supply continues to supply power. Both power supplies feed the cards 
through two diodes located on the unit backplane.

Power Line

The line cord is terminated in a IEC 320 plug. Connect this plug to the IEC receptacle located on 
the rear of the unit. 

Connect the line cord to a grounded AC power outlet. The outlet should not be under switch 
control. 

If you are unsure of the ac receptacle ground return, a separate ground wire can be run to a suitable 
grounding point. Figure 1-3 shows the ac grounding standoff located at the rear of the enclosure. 
The wire used for this ground must be a minimum of 16 AWG and long enough to connect from 
the chassis grounding post labeled GND to the ground point without any splicing.

Do not secure the power cord to any building surface.

NOTE

Содержание Metroplex 6000 MP 6960

Страница 1: ...Installation and Operation Metroplex 6000 GDC 086R601 001 Issue 1 June 1996 General DataComm Wallmount Enclosure Model MP 6960...

Страница 2: ......

Страница 3: ...ty and EMC 1 6 Chassis Grounding Post 1 6 Signal Ground 1 6 E M Ground 1 6 Ground Start Ground 1 6 Power Supply Redundancy 1 7 Power Line 1 7 Internal Power Supply Replacement 1 8 Installing The Conne...

Страница 4: ...for the enclosures built in power supply See Figure 1 1 It features 6 slots for system cards and blank fillers Wallmounted or optionally rackmounted with the optional rackmounting kit Internal 60 watt...

Страница 5: ...ling air and exhaust of warm air The ambient temperature should not exceed 122 F 50 C Do not install the enclosure directly above equipment that generates a large amount of heat such as power supplies...

Страница 6: ...of Wallmount Enclosure Figure 1 2 Installation of Wallmount Enclosure Cont SIDE COVER INSERT Plywood Mounting Surface CARDS General DataComm Inc Rear Bezel Top Vent Bottom Vent Front View Wallmount P...

Страница 7: ...the wallmount plate tabs and moving the enclosure to the right and down Rear Panel Connections The following paragraphs describe the rear panel connections to the Wallmount Enclosure See Figure 1 3 Fi...

Страница 8: ...ually best for AC power line noise immunity but a problem can exist if signal grounds on two equipments at different chassis ground potentials are connected together via a data cable A large current c...

Страница 9: ...nc Model No PUP110 14 Connect the black negative wire to the terminal labeled BATT and the red positive wire to the terminal labeled BATT If the Metroplex 6000 internal power supply fails this externa...

Страница 10: ...power supply should be performed by qualified service personnel only Antistatic Precautions Electrostatic discharge ESD results from the buildup of static electricity and can cause computer components...

Страница 11: ...th hands until the assembly seats in the rear connector 3 Secure the card by tightening the front panel screws with a screwdriver 4 Any card may be placed in any slot with the exception of the platfor...

Страница 12: ...utput 24 VDC at 3 3A Regulation 2 Power Output maximum 60 W Safety requirements EN60950 UL1459 CSA 225 Temperature Range Operating 0 to 50 C ambient UL Listing Parts List Item Part No 6 Slot Wallmount...

Отзывы: