060R122-000
SpectraComm Dual V.34 Modem
6-1
Issue 15
Installation and Operation
Chapter 6:
Tests
Overview
This chapter describes tests that can be invoked to isolate a trouble condition. The tests can isolate
a problem to the data connection, data set operation, or the DTE interface level. See
for
a sequence of tests for fault isolation.
Figure 6-1
Fault Isolation Sequence
Note
a.
On-line tests, which involve data transmitted from one modem to another, can be performed with the
modems operating in either synchronous mode or direct (N1) asynchronous mode. They cannot be
initiated until the modem has been in data mode for approximately 30 seconds.
b.
Once a modem is in Slave RDL, it ignores all requests other than AL.
c.
If an MRDL request does not get a response from the Slave modem at 2400 bps, the Master drops
the line.
FAIL
FAIL
FAIL
FAIL
PASS
PASS
PASS
PASS
FAIL
PASS
START
Perform analog loopback
with self-test
Local modem problem
Perform analog loopback
Local terminal or local
terminal-to-modem
connection problem
Perform remote digital
loopback with self-test
Perform local digital
loopback with self-test
Communication
line problem
Remote modem
problem
Perform remote digital
loopback with self-test
at remote modem
Communication
line problem
Remote terminal or remote
terminal-modem
connection problem
Pass
or
fail
Pass
or
fail
Pass
or
fail
Pass
or
fail
Pass
or
fail