• Use generator only for intended uses.

• If you have questions about intended use, ask dealer or call

the Generac generator helpline at 1-800-270-1408.

• Operate generator only on level surfaces.

• DO NOT expose generator to excessive moisture, dust, dirt,

or corrosive vapors.

• DO NOT insert any objects through cooling slots.

• If connected devices overheat, turn them off and disconnect

them from generator.

• Shut off generator if:

-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.

Improper treatment of generator can damage it and
shorten its life.

CAUTION

• DO NOT tamper with governed speed. Generator supplies

correct rated frequency and voltage when running at governed
speed.

• DO NOT modify generator in any way.

Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.

CAUTION

• See “Don’t Overload Generator”.

• Start generator and let engine stabilize before connecting

electrical loads.

• Connect electrical loads in OFF position, then turn ON for

operation.

• Turn electrical loads OFF and disconnect from generator

before stopping generator.

Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.

CAUTION

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.

• DO NOT check for spark with spark plug removed.

Unintentional sparking can result in fire or
electric shock.

WARNING

• DO NOT touch hot surfaces.

• Allow equipment to cool before touching.

• The generator must be at least 5 feet from structures having

combustible walls and/or other combustible materials.

• Keep at least 3 feet of clearance on all sides of generator for

adequate cooling, maintenance and servicing.

• In the State of California a spark arrester is required by law

(Section 4442 of the California Public Resources Code). Other
states may have similar laws. Federal laws apply on federal
lands. If you equip the muffler with a spark arrester, it must be
maintained in effective working order.

Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Combustible debris, such as leaves, grass, brush,
ect. can catch fire.

WARNING

Содержание WHEELHOUSE 1646-3

Страница 1: ...Manual No 193711GS Revision 4 11 29 2004 Safety Rules 2 4 Know Your Generator 5 Assembly 6 7 Operation 8 11 Product Specifications 12 Maintenance 12 Storage 13 Troubleshooting 14 Notes 15 Warranty La...

Страница 2: ...Agency For warranty information refer to the engine owner s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages t...

Страница 3: ...t a cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates befor...

Страница 4: ...oads OFF and disconnect from generator before stopping generator Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it CAUTION WHEN ADJUSTING OR...

Страница 5: ...Locking Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects...

Страница 6: ...engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications 1 Use clean fresh regular UNLEADED fuel with a minimum of 85 octane DO NOT use fuel which contains M...

Страница 7: ...e tank onto the frame by turning them counter clockwise Figure 5 5 Lift off the fuel tank by grasping the handle provided on the tank with one hand and putting the other hand in the finger pocket Figu...

Страница 8: ...nerator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other opening...

Страница 9: ...o load for 30 seconds to stabilize internal temperatures of engine and alternator 3 Turn engine off according to instructions given in engine owner s manual 4 Move fuel valve to Off position See Don t...

Страница 10: ...ater Figure 10 You can use the same 4 wire cord if you plan to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 2 775 watts of power at 23 1 Amps for...

Страница 11: ...tor output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additio...

Страница 12: ...NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voi...

Страница 13: ...f position Figure 4 earlier To prevent gum from forming in fuel system or on essential carburetor parts empty entire contents of both supplied fuel stabilizer containers into fuel tank and fill with f...

Страница 14: ...rt circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Generator 3 Contact local service facility Engine will no...

Страница 15: ...WheelHouse 5550 Watt Generator 15 NOTES...

Страница 16: ...dgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as adjustments fuel system cleaning and obstruction due to chemical dirt carbon or...

Отзывы: