background image

 GENERAC 1.6L ENGINE

•  All input connections in one single area
•  High coolant temperature shutdown
•  Low oil pressure shutdown
•  Low coolant level automatic shutdown
•  Overspeed automatic shutdown
• Crank 

timer

• Exercise 

timer

• Oil 

drain 

extension

• Cool 

flow 

radiator

•  Closed coolant recovery system

•  UV/Ozone resistant hoses
•  Watertight state of the art electrical connectors
• Mainline 

circuit 

breaker

•  Radiator drain extension
•  Battery charge alternator
•  2 Amp static battery charger
•  Battery rack and battery cables
•  Fan and belt guards
• Isochronous 

governor

•  Flex fuel line pigtail

STANDARD EQUIPMENT

Naturally Aspirated

Gaseous Fueled

•  Innovative design and fully prototype tested
• UL 

2200 

Listed

•  Solid state frequency compensated 
 voltage 

regulator

•  Dynamic and static battery charger
•  Sound attenuated acoustically designed enclosure
• 

Whisper-Test

™  for low noise level exercise

•  Acoustically designed engine cooling system
•  State of the art digital control system with R-Series
 

digital control panel

•  High flow low noise factory engineered exhaust system
•  Watertight electrical connectors
• Rodent 

proof 

construction

• High efficiency, low distortion Generac designed

alternator

•  Vibration isolated from mounting base
•  Matching Generac transfer switches engineered and 

tested to work as a system

•  All components easily accessible for maintenance
•  Electrostatically applied powder paint

FEATURES

Standby Power Rating

30 kW 60 Hz

Liquid Cooled 

Gas Engine 

Generator Sets

Whisper-Test™

Low Speed Exercise

62 dB(A) at 23 feet

UL 2200 Listed

Transfer Switch is sold separately

COMMERCIAL SERIES

Содержание QT036

Страница 1: ... Solid state frequency compensated voltage regulator Dynamic and static battery charger Sound attenuated acoustically designed enclosure Whisper Test for low noise level exercise Acoustically designed engine cooling system State of the art digital control system with R Series digital control panel High flow low noise factory engineered exhaust system Watertight electrical connectors Rodent proof c...

Страница 2: ...ty sensing Low fuel pressure Delay on utility failure for engine start Low battery Engine warm up before transfer Low oil pressure Delay to retransfer to utility High coolant temp low coolant temp Engine cooldown timer Overspeed Exerciser not set Overcrank INTERNAL FUNCTIONS 3 position switch auto off and manual 2 wire start for any transfer switch Communicates with the Generac RTS transfer switch...

Страница 3: ...power 60 Hz cfm 95 SOUND EMISSIONS IN DBA db A 23 feet in exercise mode 62 db A 23 feet at normal operating load 75 EXHAUST Exhaust flow at rated output 60 Hz cfm 260 Exhaust temp at muffler outlet F 1025 ENGINE PARAMETERS Rated synchronous RPM 60 Hz 3600 HP at rated KW 60 Hz 48 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3 for every 10 C above C 25 1 65 for every 10 F above F 77 ...

Страница 4: ...SSURE LOW BATTERY SYSTEM READY FUSES AUTO MANUAL OFF OFF ON TIME SET EXERCISE LOW COOLANT LEVEL OVER SPEED OVER CRANK DANGER 29 29 FRONT VIEW EXHAUST AND AIR DISCHARGE LOUVERS FRONT AND SIDES VISE ACTION LATCH ONE PER DOOR ONE LIFT OFF DOOR PER SIDE OF GENERATOR 62 2 62 2 46 46 DOOR TYP DOOR TYP 27 4 DOOR TYP 33 5 33 5 6 6 MIN MIN EXHAUST MUFFLERS ENCLOSED WITHIN 30 7 30 7 FUEL LINE CONNECTION 3 4...

Отзывы: