Generac Power Systems QT022 Скачать руководство пользователя страница 3

OPERATING DATA

KW RATING (LP/NG)

22/22

ENGINE SIZE

2.4 Liter Inline 4

GENERATOR OUTPUT VOLTAGE/KW - 60Hz

KW

AMP

CB Size

120/240V, 1-phase, 1.0 pf
120/208V, 3-phase, 0.8 pf
120/240V, 3-phase, 0.8 pf

22
22
22

92
76
66

100

80
80

ENGINE FUEL CONSUMPTION 

(Natural Gas) (Propane)

Exercise cycle
25% of rated load
50% of rated load
75% of rated load
100% of rated load*

For Btu content, multiply ft

3

/hr x 2520 (LP) or ft

3

/hr x 1000 (NG)

Natural Gas

(ft

3

/hr.)

42

100
190
255
316

Propane

 

(gal/hr.)

 

cu ft/hr

 

0.44

 

16

 

1.1

 

40

 

2.1

 

75

 

2.8

 

101

 

3.4

 

125

ENGINE COOLING

Air flow 

(inlet air including alternator and combustion air) 

ft

3

/min.

System coolant capacity

 

US gal.

Heat rejection to coolant

 

BTU/hr.

Max. operating air temp. on radiator

 

°C (°F)

Max. ambient temperature

 

°C (°F)

2,400

3

99,000

60 (150)
50 (140)

COMBUSTION AIR REQUIREMENTS

Flow at rated power 60 Hz

 

cfm

68

SOUND EMISSIONS IN DBA

Exercising at 7 meters
Normal operation at 7 meters

61
70

EXHAUST

Exhaust flow at rated output 60 Hz

 

cfm

Exhaust temp. at muffler outlet

 

°F

165
900

ENGINE PARAMETERS

Rated synchronous RPM

 

60 Hz

1800

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

Temperature Deration

3% for every 10 °C above - °C

1.65% for every 10 °F above - °F

Altitude Deration

1% for every 100 m above - m

3% for every 1000 ft. above - ft.

25
77

183
600

*  Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. 

RATING: 

 All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a 

reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage.  There is no overload capability for this rating. Ratings are in accordance with 
ISO-3046-1. Design and specifications are subject to change without notice.
KW rating is based on LPG Fuel and may derate with natural gas.

Generac

®

 QuietSource

®

 Series Standby Generator - 22 kW

®

Содержание QT022

Страница 1: ...e surge loads to the engine An unequalled 1 voltage regulation SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know how for the entire unit from the engine to the smallest electronic component GENERAC TRANSFER SWITCHES Long life and reliability are synonymous with GENERAC POWER SYSTEMS One reason for this confidence is that the GENERAC product line...

Страница 2: ...res protection against mother nature Electrostatically applied textured epoxy paint for added durability Enclosed critical grade muffler Quiet critical grade muffler is mounted inside the unit to prevent injuries Small compact attractive Makes for an easy eye appealing installation SAE Sound attenuated enclosure ensures quiet operation ENGINE SPECIFICATIONS MAKE Generac MODEL In line CYLINDERS 4 D...

Страница 3: ...ising at 7 meters Normal operation at 7 meters 61 70 EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp at muffler outlet F 165 900 ENGINE PARAMETERS Rated synchronous RPM 60 Hz 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3 for every 10 C above C 1 65 for every 10 F above F Altitude Deration 1 for every 100 m above m 3 for every 1000 ft above ft 25 77 183 600 Refer t...

Страница 4: ...Low Battery Protection Standard 50 Event Run Log Standard Future Set Capable Exerciser Standard Incorrect Wiring Protection Standard Internal Fault Protection Standard Common External Fault Capability Standard Governor Failure Protection Standard QT022 CUSTOMER SUPPLIED NEUTRAL WIRE LIQUID COOLED INSTALLATION NEUTRAL BLOCK UTILITY SUPPLY FROM SERVICE DISCONNECT TO BE RUN IN TWO DIFFERENT CONDUITS ...

Страница 5: ...INSTALLATION LAYOUT QT022 ...

Страница 6: ...erform a complete maintenance on Generac liquidcooled generators 5928 Nexus Wireless Remote Completely wireless and battery powered Generac s Nexus wireless remote monitor provides you with instant status information without ever leaving the house 5951 Advanced Nexus Wireless Remote Remotely control generator functions with the advanced model s LCD display In addition to remote testing of the gene...