Generac Power Systems Nexus smart Скачать руководство пользователя страница 2

Safety Rules .................................................Inside Front Cover
General Information ................................................................. 2

1.1 Introduction 

................................................................................ 2

1.2 Unpacking 

.................................................................................. 2

1.3 Equipment 

Description 

................................................................ 2

1.4  Transfer Switch Data Decal ......................................................... 2
1.5  Transfer Switch Enclosure ........................................................... 3
1.6  Safe Use Of Transfer Switch........................................................ 3

Installation ............................................................................... 3

2.1  Introduction to Installation ........................................................... 3
2.2 Mounting 

.................................................................................... 3

2.3  Connecting Power Source and Load Lines .................................. 3
 

2.3.1  2-pole Mechanism ............................................................ 3

 

2.3.2  3-pole Mechanism ............................................................ 3

2.4  Connecting Start Circuit Wires .................................................... 4
2.5  Connecting Load Shed Module (LSM) Connections ..................... 4
 

2.5.1  Sequence of Operation ...................................................... 4

2.6 Auxiliary 

Contacts 

....................................................................... 5

Operation ................................................................................. 6

3.1  Functional Tests & Adjustments .................................................. 6
3.2 Manual 

Operation 

........................................................................ 6

 

3.2.1  Close to Normal Source Side ............................................ 6

 

3.2.2  Close to Emergency Source Side ...................................... 6

 

3.2.3  Return to Normal Source Side........................................... 6

3.3 Voltage 

Checks 

........................................................................... 6

 

3.3.1  Utility Voltage Checks ....................................................... 6

 

3.3.2  Generator Voltage Checks ................................................. 7

3.4  Generator Tests Under Load ........................................................ 8
3.5  Testing Load Shed Module (LSM) ............................................... 8

Electrical Data ......................................................................... 9
Exploded Views & Parts Lists ................................................ 12
Installation Diagram .............................................................. 15
Notes ..................................................................................... 16

SAFETY RULES

 

 

SAVE THESE INSTRUCTIONS!  Read the fol-

lowing information carefully before attempting 

to install, operate or service this equipment. 

Also read the instructions and information on 

tags, decals, and labels that may be affixed to 

the transfer switch. Replace any decal or label 

that is no longer legible.

 

 

DANGER!  Connection of a generator to an 

electrical system normally supplied by an 

electric utility shall be by means of suitable 

transfer equipment so as to isolate the elec-

tric system from utility distribution system 

when the generator is operating (Article 701 

Legally Required Standby Systems or Article 

702 Optional Standby Systems, as applicable). 

Failure to isolate electric system by these 

means may result in damage to generator and 

may result in injury or death to utility workers 

due to backfeed of electrical energy.

The manufacturer cannot anticipate every possible circumstance 

that might involve a hazard. The warnings in this manual, and on 

tags and decals affixed to the unit are, therefore, not all-inclusive. If 

using a procedure, work method or operating technique the manu-

facturer does not specifically recommend, ensure that it is safe for 

others. Also make sure the procedure, work method or operating 

technique chosen does not render the transfer switch unsafe.
Throughout this publication, and on tags and decals affixed to the 

generator, DANGER, WARNING, CAUTION and NOTE blocks are 

used to alert personnel to special instructions about a particular 

operation that may be hazardous if performed incorrectly or care-

lessly. Observe them carefully. Their definitions are as follows:

    After this heading, read instructions that, if not 

strictly complied with, will result in serious 

personal injury, including death.

    After this heading, read instructions that, if not 

strictly complied with, could result in serious 

personal injury, including death.

    After this heading, read instructions that, if not 

strictly complied with, might result in minor or 

moderate injury.

NOTE:

After this heading, read instructions that, if not strictly complied 

with, may result in damage to equipment and/or property.

Table of Contents

Содержание Nexus smart

Страница 1: ...This manual should remain with the unit Technical Manual Nexus Smart Switch...

Страница 2: ...system from utility distribution system when the generator is operating Article 701 Legally Required Standby Systems or Article 702 Optional Standby Systems as applicable Failure to isolate electric s...

Страница 3: ...and national electrical and building codes When using this equipment comply with regulations the National Electrical Code NEC CSA Standard C22 1 Canadian Electric Code and Occupational Safety and Heal...

Страница 4: ...the event of a drop in generator frequency overload Loads to be shed are grouped in 4 priority levels on the LSM Priority 1 and 2 has connections for both one air conditioner and one contactor Both a...

Страница 5: ...mensions drawing Handle transfer switches carefully when install ing Do not drop the switch Protect the switch against impact at all times and against con struction grit and metal chips Never install...

Страница 6: ...IONS The LSM can control an air conditioner 24 Vac directly or a sepa rate contactor 120 Vac which can control any load connected to it See Figure 2 2 2 5 1 SEQUENCE OF OPERATION The 4 green status LE...

Страница 7: ...ormally Open Open Closed Common to Normally Closed Closed Open NOTE Auxiliary Contacts are rated 10 amps at 125 or 250 volts AC DO NOT EXCEED THE RATED VOLTAGE AND CURRENT OF THE CONTACTS Figure 2 3 4...

Страница 8: ...SOURCE SIDE Before proceeding verify the position of the switch by observing window A in Figure 3 1 on page 6 If window A reads ON the contacts are closed in the normal position no further action is r...

Страница 9: ...2 to NEUTRAL 120 123 VAC Failure to do so may result in damage to cer tain rotary equipment 5 When certain that UTILITY supply voltage is correct and compatible with transfer switch ratings turn OFF t...

Страница 10: ...etting the AUTO OFF MANUAL switch to its OFF position 7 Move the switch s main contacts back to the UTILITY position For example load connected to utility power supply Refer to Manual Operation Handle...

Страница 11: ...9 Interconnection Drawing No 0H7453 C Electrical Data...

Страница 12: ...10 Electrical Data Wiring Diagram Schematic Drawing No 0H7257 C...

Страница 13: ...11 Wiring Diagram Schematic Drawing No 0H7257 C Electrical Data...

Страница 14: ...12 Parts List on page 14 Exploded Views Parts Lists 400A Assembly Drawing No 0H7267 C...

Страница 15: ...13 Parts List on page 14 400A Assembly Drawing No 0H7267 C Exploded Views Parts Lists...

Страница 16: ...J3806C 1 DECAL DATA XFER SW 23 064101 6 NUT HEX FL WHIZ 3 8 16 24 0F59400ST14 1 SUBPLATE 24 36 ENCL RTS GY4 25 087680 1 NUT WING M6 1 0 26 063378 4 HOLDER CABLE TIE 27 064761 4 TIE WRAP UL 5 6 X 10 NA...

Страница 17: ...9 6mm 24 0 917mm 36 1 TRIPLE EKO SUITABLE FOR 1 1 25 1 50 CONDUIT 3 PLACES 254mm 10 0 794mm 31 3 60 8mm 2 4 61 3mm 2 4 487mm 19 2 MOUNTING HOLES 6 35mm 0 25 4 PLACES Installation Diagram Drawing No 0F...

Страница 18: ...16 Notes...

Страница 19: ...17 Notes...

Страница 20: ...Part No 0H7443 Revision C 08 05 11 Printed in U S A...

Страница 21: ......

Страница 22: ...AL DATA XFERSW 0J3806C 1 DECAL DATA XFERSW 23 064101 6 NUT HEX FL WHIZ 3 8 16 24 0F59400ST14 1 SUBPLATE 24 36 ENCL RTS GY4 25 087680 1 NUT WING M6 1 0 26 063378 4 HOLDER CABLE TIE 27 064761 4 TIE WRAP...

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Отзывы: