Generac Power Systems MEGAFORCE 6500 Скачать руководство пользователя страница 3

MEGAFORCE™ 6500 Extended Life Generator

3

• The generator produces a very powerful voltage that

can cause serious injury or death by electrocution.

Never touch bare wires or receptacles. Never permit

a child or any unqualified person to operate the

generator.

• Never handle any kind of electrical cord or device

while standing in water, while barefoot or while

hands or feet are wet.

• Use a ground fault circuit interrupter (GFCI) in any

damp or highly conductive area (such as metal

decking or steel work).

• Never use worn, bare, frayed or otherwise damaged

electrical cords with the generator.

•

Gasoline is highly FLAMMABLE and its vapors

are EXPLOSIVE. Never allow smoking, open

flames, sparks or heat in the vicinity while

handling gasoline. Avoid spilling gasoline on a

hot engine.

Comply with all laws regulating storage

and handling of gasoline.

•

Do Not

overfill the fuel tank. Always allow room for

fuel expansion. If tank is overfilled, fuel can overflow

onto a hot engine and cause a FIRE or an

EXPLOSION.

• Never store a generator with fuel in the tank where

gasoline vapors might reach an open flame, spark or

pilot light (as on a furnace, water heater, clothes

dryer). FIRE or an EXPLOSION may result.

• The unit requires an adequate flow of cooling air for

its continued proper operation. Never operate the

unit inside any room or enclosure where the free

flow of cooling air into and out of the unit might be

obstructed. Allow at least 2 feet of clearance on all

sides of generator or you could damage the unit.

Read “Cold Weather Operation” on page 9.

• Never start or stop the unit with electrical loads

connected to receptacles AND with the connected

devices turned ON. Start the engine and let it

stabilize before connecting any electrical loads.

Disconnect all electrical loads before shutting down

the generator.

•

Do Not

insert any object through the unit’s cooling

slots or damage to you or the unit could happen.

•

Never operate the generator:

in rain; in any enclosed compartment; when

connected electrical devices overheat; if electrical

output is lost; if engine or generator sparks; if flame

or smoke is observed while unit is running; if unit

vibrates excessively.

GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame

and external electrically conductive parts of this

generator be properly connected to an approved earth

ground. Local electrical codes may also require proper

grounding of the unit. For that purpose, a

GROUNDING WING NUT is provided on the

generator end (Figure 1).

Generally, connecting a No. 12 AWG (American Wire

Gauge) stranded copper wire to the grounding wing

nut and to an earth–driven copper or brass grounding

rod (electrode) provides adequate protection against

electrical shock. Be careful to keep the grounding wire

attached after connecting the stranded copper wire.

However, local codes may vary widely. Consult with a

local electrician for grounding requirements in your

area.
Properly grounding the generator helps prevent

electrical shock if a ground fault condition exists in the

generator or in connected electrical devices. Proper

grounding also helps dissipate static electricity, which

often builds up in ungrounded devices.

Grounding Wing Nut

Figure 1 — Grounding Wing Nut

Содержание MEGAFORCE 6500

Страница 1: ...ons Before taking your unit back to the store call the generator helpline at 1 800 270 1408 M F 8 5 CT MEGAFORCE 6500 GENERAC The Reliable Ones Safety Assembly Operation Maintenance Parts French S ret...

Страница 2: ...g or enclosure including the generator compartment of a recreational vehicle RV Carbon monoxide poisoning fire and or an explosion may result No user performed modifications including venting of exhau...

Страница 3: ...ld Weather Operation on page 9 Never start or stop the unit with electrical loads connected to receptacles AND with the connected devices turned ON Start the engine and let it stabilize before connect...

Страница 4: ...rload Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for grounding of unit Hour Meter Used to schedule preventative maintenance tasks Idle Control Switch With this switch set to ON...

Страница 5: ...lat Remove all packing material carton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1...

Страница 6: ...the right side to the base of the lift bar bracket Attach the lift bar to the cradle using four cap screws and four lock nuts BEFORE STARTING THE ENGINE Add Oil WARNING Any attempt to crank or start...

Страница 7: ...dorless and deadly gas WARNING Temperature of muffler and nearby areas may exceed 150 F 65 C Avoid these areas Unplug all electrical loads from generator receptacles before starting the engine Make su...

Страница 8: ...ns constantly at the normal high engine speed Always have the switch Off when starting and stopping the engine Charging a Battery DANGER Storage batteries give off explosive hydrogen gas while recharg...

Страница 9: ...shelter Cut off all flaps Cut out one of the long sides of the box to expose exhaust side of unit Ensure a minimum of two feet clearance between open side of box and nearest object Cut appropriate slo...

Страница 10: ...tuations 1 Line to line shocks 2 Current overloads or line to line short circuits The fuse or circuit breaker at the distribution panel must provide such protection Testing the GFCI Test your GFCI out...

Страница 11: ...EMA L5 30 plug with this receptacle Connect a 3 wire cord set rated for 125 Volt AC loads at 30 Amps to the plug Figure 12 Use this receptacle to operate 120 Volt AC 60 Hz single phase loads requiring...

Страница 12: ...unning watts of all other connected loads Device Load watts Air Conditioner 12 000 Btu 1700 Air Conditioner 24 000 Btu 3800 Air Conditioner 40 000 Btu 6000 Battery Charger 20 Amp 500 Belt Sander 3 100...

Страница 13: ...ristle brush may be used to loosen caked on dirt or oil A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspect coolin...

Страница 14: ...MEGAFORCE 6500 Extended Life Generator 14 NOTES...

Страница 15: ...cleaner 3 Out of gasoline 4 Stale gasoline 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in gasoline 8 Overchoking 9 Excessively rich fuel mixture 10 Intake valve stuck open o...

Страница 16: ...MEGAFORCE 6500 Extended Life Generator 16 SCHEMATIC DIAGRAM...

Страница 17: ...MEGAFORCE 6500 Extended Life Generator 17 WIRING DIAGRAM...

Страница 18: ...MEGAFORCE 6500 Extended Life Generator 18 EXPLODED VIEW MAIN UNIT...

Страница 19: ...Carrier 35 22769 1 WASHER 10 Int Shakeproof 36 86494 1 SCREW M6 1 0 x 16 Wing 37 86292 7 SCREW 10 Self Drilling 38 77395 4 NUT M6 Flange Lock 39 83465 4 GROMMET Tank 40 57058 4 HHCS M6 1 0 x 55 Item P...

Страница 20: ...akeproof 13 68868 1 OUTLET 120 Volt 30 A Locking 14 43437 1 OUTLET 120V 240V 30A Locking 15 94373 1 RECEP GFCI 15A Item Part Qty Description 16 43108 6 WASHER M4 Flat 17 22264 6 WASHER 8 M4 Lock 18 51...

Страница 21: ...se 1 4 5 B89635 2 SPACER Wheel 6 B93696 1 BRACKET Support Leg 7 27007 2 MOUNT Vibration 8 42909 2 CAPSCREW Hex Hd M8 1 25 x 30 9 52858 12 NUT Lock M8 10 22247 2 WASHER Wheel 11 39253 2 CAPSCREW Hex Hd...

Страница 22: ...h have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in the COMPANY s judgement...

Страница 23: ...de l quipement Le g n rateur ne fournit une fr quence et un voltage corrects que lorsque le moteur tourne la vitesse pr r gl e correcte Une fr quence et ou un voltage incorrect peut endommager certai...

Страница 24: ...er dehors sinon vous risquez d endommager l appareil Lire l Op ration de Temps Froide sur la page 30 Ne jamais d marrer ou arr ter le g n rateur moteur alors que des charges lectriques sont reli es au...

Страница 25: ...un d marrage froid du moteur Pot d chappement avec arr teur d tincelles Le pot d chappement diminue le bruit du moteur est quip d un cran arr teur d tincelles Prise de 12 Volts 10 Amp res c c Cette p...

Страница 26: ...importe quelles parties manquent ou endommag appeler le helpline de g n rateur 1 800 270 1408 Le g n rateur la trousse de Roue et ascenseur Le propri taire de G n rateur et moteur s manuels Verrouill...

Страница 27: ...support de la barre de levage Attachez la barre de levage au berceau en utilisant quatre vis M8 x 45mm et quatre contre crous M8 Le ch que que tous fermoirs sont tendus AVANT LE D MARRAGE DU MOTEUR Aj...

Страница 28: ...t des surfaces avoisinantes peut d passer 65 C 150 F viter ces endroits D brancher toutes les charges lectriques des prises du g n rateur avant de mettre en route le moteur S assurer que l appareil es...

Страница 29: ...s d marrez ou arr tez le moteur Recharge d une Batterie DANGER Les batteries de remisage produisent des gaz hydrog nes explosifs pendant la recharge Un m lange explosif sera pr sent autour de la batte...

Страница 30: ...upez un des grands c t s de la bo te pour exposer le c t chappement de l appareil Laissez un minimum de 60 cm 2 pieds d intervalle entre le c t ouvert de la bo te et l objet le plus proche Couper les...

Страница 31: ...s 1 Chocs lectriques entre lignes 2 Surcharges de courant ou courts circuits entre lignes Le fusible ou le disjoncteur au tableau de distribution doit fournir une telle protection V rification de l in...

Страница 32: ...une prise m le NEMA L5 30 avec cette prise femelle Reliez une rallonge trois c bles de 125 Volts c a 30 Amp res la prise ou davantage cette prise Figure 26 Utilisez cette prise pour faire marcher des...

Страница 33: ...s volts par les amp res pour obtenir les watts volts x amp res watts Les articles mentionn s dans le guide la Figure 28 vous sont fournis pour vous aider d terminer combien d articles votre g n rateur...

Страница 34: ...res Une brosse douce poils soyeux peut tre utilis e pour d gager la salet l huile durcie Un aspirateur peut tre utilis pour ramasser la salet et les d bris qui ne sont pas coll s On peut se servir d a...

Страница 35: ...de la bougie n est pas reli la bougie 6 Mauvaise bougie 7 Il y a de l eau dans l essence 8 Trop de starter 9 M lange de carburant trop riche 10 Soupape d admission bloqu e en position ouverte ou ferm...

Страница 36: ...ent t sujets une installation ou une modification incorrecte ou non autoris e un mauvais usage une n gligence un accident une surcharge une vitesse excessive un entretien des r parations ou un remisag...