Operation
Owner’s Manual for MLT4200IVF4 Light Tower
23
Installation of a transfer switch or other type of remote
starting device is the responsibility of the user. Installation
of such devices must be performed by following all
directions supplied by the manufacturer of the switch. If
attaching the unit to a power supply normally serviced by
a utility company, notify the utility company and check
local and state regulations. Familiarize yourself with all
instructions and warning labels supplied with the switch.
AUTO Exercise Timer
The controller is capable of starting and stopping the unit
automatically, based on a programmable schedule. Units
installed in a standby application should be exercised
regularly to maintain operating condition and to ensure
responsiveness in an emergency situation. Use the
following procedures to operate the unit in AUTO mode:
NOTE:
The controller must be in AUTO mode to run at
the programmed time. Use a trickle or solar battery
charger to prevent the controller from draining the battery
while in AUTO mode.
1. Push both the STOP/RESET (O) and AUTO but-
tons simultaneously.
2. Push the
↑
button until the wrench icon is selected.
Push the AUTO button to select it and enter the
parameters.
3. Adjust the parameter number to enable the desired
timer. When the correct parameter number is
showing, press the AUTO button to enter it. Press
the MANUAL/START (I) button to change it to 1 to
enable the timer and press the AUTO button to
save it.
NOTE:
The
↑
and
↓
buttons will adjust the hundredths
place of the parameter number and the MANUAL/START
(I) and STOP/RESET (O) buttons will adjust the low
digits. Up to eight events can be scheduled at a time.
4. Adjust the parameter number to adjust the time of
the desired event and then press the AUTO button
to enter it. Press the MANUAL/START (I) and
STOP/RESET (O) buttons to change the time.
Holding down either button will change the time
faster. Press the AUTO button to save the time.
5. Adjust the parameter number to adjust the day of
the week and press the AUTO button to enter it.
Press the MANUAL/START (I) and STOP/RESET
(O) button to change to the desired day and press
the AUTO button to save it.
NOTE:
Only one day can be chosen per event if
parameter 903 is “1” (monthly).
6. Adjust the parameter number to adjust duration of
the timer and press the AUTO button to enter it.
Press the MANUAL/START (I) or STOP/RESET
(O) buttons to change the duration and press the
AUTO button to save it.
NOTE:
If any of the scheduled time slots are currently
active, the controller will begin the starting sequence and
start the unit provided there are no shutdown conditions
present.
The times for the scheduled timers and events are based
on the internal clock for the controller. Use the
corresponding parameters to adjust to the correct time of
the day and correct date.
This table lists the parameters needed to schedule an
event and to adjust the clock within the controller.
NOTE:
If parameter 902 is “0”, then the auto exercise
timer is enabled and if it is “1”, then the autolight timer is
enabled.
F
Utility Meter
WHITE
Incoming Utility Power
GRAY
Normal Utility Power Circuit
BLACK
Emergency Generator Power Circuit
(000150)
DANGER
Electrocution. Never connect this unit to the electrical
system of any building unless a licensed electrician
has installed an approved transfer switch. Failure to
do so will result in death or serious injury.
(000155)
WARNING
Only a trained and licensed electrician should perform
wiring and connections to unit. Failure to follow proper
installation requirements could result in death, serious
injury, and damage to equipment or property.
Parameter
Description
Details
Configuration Parameters - Scheduler
901
Enable Scheduler
On (1), Off (0)
902
Schedule Run On or Off
Load On (1), Off (0)
903
Schedule Period
Weekly (0), Monthly (1)
904
Scheduler (1) Start Time
0:00:00
Содержание MAGNUM MLT4200IVF4
Страница 32: ...Operation 28 Owner s Manual for MLT4200IVF4 Light Tower This page intentionally left blank ...
Страница 38: ...Maintenance 34 Owner s Manual for MLT4200IVF4 Light Tower This page intentionally left blank ...
Страница 50: ...Wiring Diagrams 46 Owner s Manual for MLT4200IVF4 Light Tower This page intentionally left blank ...
Страница 52: ...48 Owner s Manual for MLT4200IVF4 Light Tower This page intentionally left blank ...
Страница 53: ...Owner s Manual for MLT4200IVF4 Light Tower 49 This page intentionally left blank ...
Страница 54: ...50 Owner s Manual for MLT4200IVF4 Light Tower This page intentionally left blank ...
Страница 55: ......