5. After the unit shuts down, move the Control Power
switch to the OFF (O) position.
NOTE:
Disconnect the battery if the unit is to be stored
for an extended period. Refer to the engine operator’s
manual for additional extended storage procedures.
Automatic Shutdown
This unit is equipped with a low oil pressure and high
coolant temperature automatic shutdown system. This
system will automatically shut off the fuel supply to stop
the engine if oil pressure drops too low or the engine
exceeds normal operating temperature. Return the
Control Power switch to the STOP position to reset the
unit after the cause of shutdown has been determined.
Emergency Stop
See
. The unit is equipped with one
emergency stop button, clearly labeled “EMERGENCY
STOP.” The button can be accessed and activated with
all doors closed and locked.
Activate the emergency stop button by pushing it in until
it locks down. This trips the main circuit breaker, which
will open the contact and disconnect the load to the
connection lugs. An emergency stop also opens the fuel
circuit, shutting down the engine. The emergency stop
fault will be displayed on the control panel.
Figure 3-8. Emergency Stop Switch
The emergency stop button will remain locked until it is
pulled out.
NOTE:
To shut down the unit under any other
circumstances, refer to
Lowering Mast—Manual Winch
1. Shut down the lights and engine. See
.
2. Lower the mast.
3. Use the winch handles to collapse the mast to its
lowest position. Verify that the electrical cord does
not get caught in, or pinched by, the mast while it is
being lowered.
IMPORTANT NOTE: Contact an ASD immediately if
the mast hangs up or the winch cable develops
slack.
4.
See
. If the unit is going to be moved,
rotate the mast so the lights face the rear of the unit.
Figure 3-9. Stowed (Travel) Position
To rotate the mast:
a. Loosen the mast rotation knob.
b. Rotate the mast until the white arrows are
aligned and the metal stop tabs are touching.
c. Tighten the mast rotation knob.
Lowering Mast—Electric Winch
(if equipped)
Electrically Lowering Mast
NOTE:
Control power must be on to lower the mast with
the electric winch.
1. Shut down the lights and engine. See
.
2. Press and hold the winch control switch downward
to collapse the mast to its lowest position. Verify
the electrical cord does not get caught in, or
pinched by, the mast while it is being lowered.
CAUTION
(000246)
Equipment Damage. The emergency stop switch is
not to be used to power down the unit under normal
operating circumstances. Doing so will result in
equipment damage.
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
Содержание MAGNUM MLT4060MVD
Страница 11: ...Introduction and Safety Owner s Manual for MLT4060MVD Light Tower 7 Figure 1 1 External Decals...
Страница 14: ...Introduction and Safety 10 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 28: ...General Information 24 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 42: ...Operation 38 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 48: ...Maintenance 44 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 52: ...Electrical Drawings 48 Owner s Manual for MLT4060MVD Light Tower Components Located on Engine p 2...
Страница 53: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 49 Components Located on Engine p 3...
Страница 54: ...Electrical Drawings 50 Owner s Manual for MLT4060MVD Light Tower Components Located on Engine p 4...
Страница 55: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 51 Accessories...
Страница 56: ...Electrical Drawings 52 Owner s Manual for MLT4060MVD Light Tower Optional Accessories...
Страница 57: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 53...
Страница 58: ...Electrical Drawings 54 Owner s Manual for MLT4060MVD Light Tower...
Страница 60: ...Electrical Drawings 56 Owner s Manual for MLT4060MVD Light Tower...
Страница 62: ...Electrical Drawings 58 Owner s Manual for MLT4060MVD Light Tower Components Located in LED Box...
Страница 63: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 59 Engine Control Module Function Table...
Страница 64: ...Electrical Drawings 60 Owner s Manual for MLT4060MVD Light Tower Engine Control Module Connections...
Страница 65: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 61 AC Schematic...
Страница 66: ...Electrical Drawings 62 Owner s Manual for MLT4060MVD Light Tower Relays p 1...
Страница 67: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 63 Relays p 2...
Страница 68: ...Electrical Drawings 64 Owner s Manual for MLT4060MVD Light Tower DC Connections p 1...
Страница 69: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 65 DC Connections p 2...
Страница 70: ...Electrical Drawings 66 Owner s Manual for MLT4060MVD Light Tower...
Страница 71: ......